Summary
The goal of this clinical trial is to evaluate a new, noninvasive method for continuously measuring blood pressure during surgery. This method combines two common types of signals - pulse oximetry and electrocardiography (ECG) - and uses artificial intelligence (AI) to help improve accuracy. Researchers will compare this method to the standard invasive arterial blood pressure (IABP) monitoring to see if it can safely and effectively replace invasive measurements in certain situations.
In surgeries, keeping blood pressure stable is extremely important. Sudden drops (hypotension) or spikes (hypertension) in blood pressure can cause serious organ problems after surgery. That's why continuous blood pressure monitoring is necessary, especially during key moments like anesthesia induction, intubation, and surgical positioning. In high-risk patients, clinicians often use invasive monitoring by inserting a catheter into an artery. While accurate, this method can cause complications, including bleeding, infection, blood clots, and in rare cases, damage to the limb. Studies show that blood clots can occur in nearly 20% of radial arterial lines, and up to 15% of cases experience bleeding or hematoma. Even life-threatening problems such as limb ischemia and embolism still occur in about 1% of patients.
Because of these risks, noninvasive continuous blood pressure measurement (NCBPM) devices are needed. Pulse oximeters, which are already used in all surgeries, measure oxygen in the blood and produce a waveform called photoplethysmography (PPG). This waveform changes with each heartbeat and reflects blood volume and flow. It can provide useful cardiovascular information, and in recent years, researchers have explored using PPG to estimate blood pressure. However, PPG alone may not give accurate results in all patients or conditions.
One reason for this is that important heart-related signals - like the time between heartbeats (R-R interval), the heart's pumping strength, and electrical conduction - are not captured by PPG alone. These signals are available through ECG. By combining ECG with PPG, researchers hope to get a more complete understanding of each heartbeat, and use this to estimate blood pressure more accurately.
In this study, the new combined method is called CPES (combined pulse oximeter and ECG signals). It uses signals from both devices, analyzed by artificial intelligence, to generate continuous blood pressure readings. The study will compare these readings with direct invasive arterial blood pressure values.
The main question the study aims to answer is:
Can CPES accurately measure systolic and diastolic blood pressure within 5 mmHg of the invasive method? This threshold is based on international standards (AAMI) for acceptable accuracy in blood pressure monitoring during surgery.
Secondary questions include:
Can CPES track rapid blood pressure changes during critical moments, such as after anesthesia drugs are given, during laryngoscopy, intubation, and surgical maintenance? Does the accuracy of KPES stay the same when the surgical table is tilted 15 degrees up (reverse Trendelenburg) or down (Trendelenburg)? These positions are commonly used in surgery and may affect blood pressure measurements.
Participants in this study will be adult patients undergoing general anesthesia. All participants will:
Have standard invasive arterial monitoring during surgery Wear ECG electrodes and a pulse oximeter Be monitored in real time using both standard and experimental systems Be placed in different surgical positions (as tolerated) for short periods to evaluate effects on blood pressure measurement Data will be collected at various stages of surgery and in different positions. The study does not change routine care but adds additional, noninvasive sensors for research purposes.
This study may help develop safer and more comfortable ways to measure blood pressure continuously during surgery. If successful, this method could reduce the need for invasive lines in many patients, lowering the risk of complications and making surgery monitoring easier and more cost-effective. It may also be useful in settings where invasive monitoring is not possible, such as emergency departments or outpatient procedures.
Conditions
- Blood Pressure Measurement
Interventions
- DEVICE
-
CPES Monitoring
Noninvasive blood pressure data will be collected using a combined pulse oximeter and ECG signal system (CPES) during elective non-cardiac surgery under general anesthesia. This system is used for observational purposes and does not alter the standard of care. The goal is to compare CPES-derived blood pressure values with invasive arterial blood pressure measurements.
Sponsors & Collaborators
-
Nevsehir Public Hospital
lead OTHER_GOV
Principal Investigators
-
Mehmet Akif Yazar, MD · Konya City Hospital
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-04-07
- Primary Completion
- 2025-11-01
- Completion
- 2025-11-20
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Validation Study in Patients of a Non-invasive Blood Pressure Monitor for Perioperative Use
NCT03795831 ·Status: UNKNOWN
-
Contactless Vital Signs Measurement
NCT05165381 ·Status: COMPLETED
-
Comparison of Non-Invasive Blood Pressure (NIBP) Using the Biobeat Device with an Invasive Arterial Line Catheter
NCT04071015 ·Status: RECRUITING
-
Wearable Electrocardiogram Monitoring Device and Smartphone Application in Perioperative Pain Management
NCT04686526 ·Status: RECRUITING
-
Home Monitoring Study for Surgical Patients
NCT07231653 ·Status: NOT_YET_RECRUITING
-
Non-invasive and Continuous Blood Pressure Monitoring
NCT06887465 ·Status: NOT_YET_RECRUITING
-
Using Artificial Intelligence (AI)-Assisted Pulse Diagnosis Analysis on Precision Critical Medicine.
NCT04675424 ·Status: COMPLETED
-
Remote Patient Monitoring and Detection of Possible Diseases With Artificial Intelligence Telemedicine System
NCT05241483 ·Status: UNKNOWN
-
Photoplethysmography (PPG) Algorithm With Smartwatch in Evaluation of Atrial Fibrillation Burden
NCT06686940 ·Status: NOT_YET_RECRUITING
-
Study on Cardiac Output Evaluation Based on Wearable Monitoring Data
NCT06938893 ·Status: NOT_YET_RECRUITING
-
Measuring Cardiovascular Stress in Patients on Hemodialysis
NCT01267617 ·Status: COMPLETED
-
Data Collection of Heart Rate and Blood Pressure
NCT05095753 ·Status: UNKNOWN
-
Intervention Study on Digital Health Management
NCT06949306 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Observational Clinical Investigation of EKG Diagnostic Performance of the Apple Watch Augmented With an AI Algorithm
NCT05045456 ·Status: COMPLETED
-
Evaluating Wearable Smart Sensors for Continuous Measurement of Vital Signs in ICU Patients
NCT04723654 ·Status: RECRUITING
-
Remote Blood Pressure Monitoring With the Wearable SENBIOSYS Photoplethysmographic Device
NCT04379986 ·Status: COMPLETED ·Phase: NA
-
Contactless Measurement of Heart Rate, Heart Rate Variability, Breathing Rate and Blood Pressure Using Remote Photoplethysmography
NCT06829615 ·Status: COMPLETED ·Phase: NA
-
Perioperative Monitoring of Cardiac Surgery Patients With the Vitalstream Physiological Monitor
NCT05905536 ·Status: COMPLETED ·Phase: NA
-
Hospital Based Continuous Patient Monitoring System
NCT06739447 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Photoplethysmography (PPG) Algorithm with Smartwatch in Evaluation of Atrial Fibrillation Burden After Catheter Ablation
NCT06842160 ·Status: NOT_YET_RECRUITING
-
REmote Data Acquisition After SURgery
NCT04480385 ·Status: COMPLETED ·Phase: NA
-
Closed-Loop Titration of Vasopressor Infusions: Feasibility Study or Proof of Concept Study
NCT03515161 ·Status: COMPLETED ·Phase: NA
-
Non-Invasive Blood Pressure Monitoring
NCT05825937 ·Status: RECRUITING
-
Proactive Risk Evaluation for Cardiac Implantable Electronic Device Strategy Using AI-ECG
NCT07217236 ·Status: RECRUITING ·Phase: NA
-
A Home Telemonitoring System for Wearable Fetal-ECG and EHG Acquisition During Pregnancy
NCT06031142 ·Status: COMPLETED