Green or Pink? A Comparison of Pain and Procedural Difficulty With Intravenous Cannulas in the Emergency Department
NCT07629427 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 204
Last updated 2026-08-05
Summary
Peripheral intravenous catheter (PIVC) insertion is one of the most frequently performed invasive procedures in both medical and nursing practice. It is essential for blood sampling, intravenous (IV) fluid resuscitation, medication administration, blood product transfusion, and IV contrast-enhanced radiological imaging. In emergency department (ED) settings, where patients may deteriorate rapidly, timely and adequate IV access is of critical importance. Larger-bore cannulas allow faster fluid and contrast delivery and are less prone to occlusion; however, Larger-bore cannulas are often perceived to cause greater pain and procedural difficulty compared to smaller-bore cannulas. This perception may lead clinicians to prefer smaller cannulas, potentially compromising care quality in patients who may unexpectedly deteriorate.
Cannula insertion inherently causes discomfort, pain, and anxiety for patients, and multiple failed attempts further amplify these effects. Patient satisfaction, an important dimension of overall care quality, is directly influenced by pain experience and the number of insertion attempts. Patients requiring two or more attempts for successful cannulation are generally classified as having difficult intravenous access (DIVA). Repeated failed attempts are associated with vascular injury, increased patient distress, delays in diagnosis and treatment, and greater consumption of healthcare resources. The A-DIVA score, developed by Van Loon et al., enables risk stratification for IV access difficulty at triage, classifying patients as low, moderate, or high risk, and facilitating proactive measures such as ultrasound guidance or involvement of experienced personnel for high-risk patients.
This single-center, prospective, single-blind, randomized controlled trial aims to compare 18-gauge (18G) and 20-gauge (20G) PIVCs in terms of patient-reported pain intensity and nurse-reported procedural difficulty in adult ED patients with low-to-moderate A-DIVA risk. The investigators hypothesize that 18G cannulas cause similar pain and procedural difficulty compared to 20G cannulas in this patient population.
The study will be conducted at Marmara University Pendik Training and Research Hospital Emergency Department. Ethics approval has been granted by the Marmara University Faculty of Medicine Clinical Research Ethics Committee. Adult patients (18 years and older) requiring IV access for diagnostic or therapeutic purposes and classified as low or moderate A-DIVA risk will be eligible. Patients with cognitive impairment, altered mental status, or hemodynamic instability (systolic BP less than 90 mmHg or mean arterial pressure less than 65 mmHg) will be excluded.
Eligible consenting patients will be randomized 1:1 using a block randomization method (block size of 4) to either 18G or 20G cannula insertion. Cannula assignment will be delivered to nurses in sealed envelopes. Patients will be blinded to cannula size using blackout goggles. Cannulation will be performed by ED nurses following standard antiseptic and securement procedures, targeting the dorsum of the hand, forearm, or antecubital fossa. If the first attempt fails, at least one additional attempt with the assigned cannula will be required before allowing free choice of cannula and site.
The primary outcomes are patient-reported pain intensity and nurse-reported procedural difficulty, each assessed using a 10 cm Visual Analog Scale (VAS) immediately after the first cannulation attempt and compared between the 18G and 20G cannula groups. Secondary outcomes include the comparison of first-attempt cannulation success rate between the 18G and 20G cannula groups. This comparison will also be performed separately according to cannulation site, operator experience, A-DIVA risk category, patient age, and patient sex.
A total of 204 patients (102 per group) will be enrolled, based on 90% power, 5% type I error, a minimum clinically important difference of 13 mm on the VAS, and a 10% dropout allowance.
Conditions
- Peripheral Catheterization
- Veins
- Emergency Department Patient
- Pain
- Procedural Difficulty
Interventions
- DEVICE
-
18-gauge peripheral intravenous cannula
Peripheral intravenous cannulation performed using an 18-gauge (18G, green) cannula inserted into the dorsum of the hand, forearm, or antecubital fossa by an emergency department nurse following standard antiseptic and securement procedures. No local anesthetic agents will be used. Patients will be blinded to cannula size using blackout goggles.
- DEVICE
-
20-gauge peripheral intravenous cannula
Peripheral intravenous cannulation performed using a 20-gauge (20G, pink) cannula inserted into the dorsum of the hand, forearm, or antecubital fossa by an emergency department nurse following standard antiseptic and securement procedures. No local anesthetic agents will be used. Patients will be blinded to cannula size using blackout goggles.
Sponsors & Collaborators
-
Marmara University Pendik Training and Research Hospital
lead OTHER
Principal Investigators
-
Erhan Altunbas · Marmara University Scholl Of Medicine
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-07-23
- Primary Completion
- 2026-07-30
- Completion
- 2026-08-03
Countries
- Turkey (Türkiye)
Study Locations
More Related Trials
-
Intraosseous Versus Intravenous Vascular Access During Cardiac Arrest
NCT01119807 ·Status: COMPLETED ·Phase: NA
-
Single-operator Ultrasound-guided IV Placement by Emergency Nurses
NCT01439113 ·Status: COMPLETED ·Phase: NA
-
Effect of Tubular Bandage Application on Peripheral Intravenous Catheter Usage Time and Infiltration in Children
NCT06579820 ·Status: RECRUITING ·Phase: NA
-
Evaluation of Airway Adjuncts for Intubation in Entrapped Patients With Difficult Airway Access
NCT06609499 ·Status: COMPLETED ·Phase: NA
-
Intravascular Access of COVID-19 Patient Under Personal Protective Equipment
NCT04366297 ·Status: COMPLETED ·Phase: NA
-
Efficiency, and Emergency Department Nurse Preference Between 2 Methods of Visualization: A Pilot Study
NCT04811430 ·Status: COMPLETED
-
Discomfort During Intravenous Cannulation in an Emergency Department: Impact of Communication
NCT03502655 ·Status: COMPLETED ·Phase: NA
-
The Effect of Cold Spray and Ice Applied During Intravenous Access on Pain and Fear i in Pediatric Emergency Unit
NCT06109298 ·Status: COMPLETED ·Phase: NA
-
The Effect of Large Versus Small Clog Size on Emergency Response Time
NCT04406220 ·Status: COMPLETED ·Phase: NA
-
The Effects of Viscoelastometry Guided Resuscitation During Burn Excision on Post Resuscitation Infections
NCT03730415 ·Status: COMPLETED ·Phase: NA
-
Which Technique is Effective in Reducing the Pain of Peripheral Intravenous Catheterization in Pediatric Patients, Infra-Red Light or Buzzy®?
NCT05523518 ·Status: UNKNOWN ·Phase: NA
-
The Effect of Three Different Local Cold Applications on Pain and Ecchymosis in Subcutaneous Heparin Injections
NCT04235244 ·Status: COMPLETED ·Phase: NA
-
Ultrasound vs Veinviewer in Patients With Difficulty IV Access
NCT02618252 ·Status: WITHDRAWN ·Phase: NA
-
Unnoticed Gloves Perforation
NCT02299752 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Three Methods for NG Tube Placement
NCT03699306 ·Status: COMPLETED ·Phase: NA
-
Effect of Language and Confusion on Pain During Peripheral Intravenous Catheterization (KTHYPE)
NCT02662322 ·Status: COMPLETED ·Phase: NA
-
I-Gel in Out-of-hospital Cardiac Arrest in Norway
NCT02090218 ·Status: TERMINATED ·Phase: NA
-
Ultrasound Guided Versus Landmark Guided Arterial Line Placement by Emergency Medicine Interns
NCT03326739 ·Status: COMPLETED ·Phase: NA
-
Hemodynamic Effects of Cold Versus Warm Fluid Bolus
NCT03209271 ·Status: COMPLETED ·Phase: NA
-
Thermogard™ Efficacy Trial
NCT00822796 ·Status: TERMINATED ·Phase: NA
-
Evaluation of a Touchless Vein Scanner for Venepuncture and Cannulation in Pediatric Patients
NCT01434537 ·Status: COMPLETED
-
Effect Of Local Cold Applıcatıon On Paın and Vıtal Sıgns Durıng Port Catheter Needle Insertıon
NCT06816420 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Dry Cold Application on Pain and Bruise at the Subcutaneous Injection Site Among Patients Admitted in ICU
NCT03233321 ·Status: COMPLETED ·Phase: NA
-
Cold Application on the Subcutaneous Injection
NCT05771285 ·Status: COMPLETED ·Phase: NA
-
Comparison of the Effects of ShotBlocker, Virtual Reality Glasses and Cold Application in Subcutaneous Heparin Injection
NCT05833646 ·Status: COMPLETED ·Phase: NA