Derivation and Validation of the Aortic Valve Echocardiographic Calcium Score to Confirm Severe Aortic Stenosis: the Echo-AVCS Study
NCT07620925 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 250
Last updated 2026-06-04
Summary
The Echo-AVCS Study is an investigator-initiated, prospective, multicenter observational study designed to derive and validate an artificial intelligence (AI)-based echocardiographic aortic valve calcium score (Echo-AVCS) for confirming severe aortic stenosis (AS). Transthoracic echocardiography (TTE) is the standard imaging modality for assessing AS severity; however, discrepancies between valve area and transvalvular gradient measurements may complicate diagnosis, particularly in low-flow or discordant AS presentations. Cardiac computed tomography (CT)-derived aortic valve calcium scoring is currently used to resolve diagnostic uncertainty, but it involves additional cost and radiation exposure. This study will enroll consecutive adult patients undergoing clinically indicated TTE and cardiac CT with calcium scoring performed within 3 months. Standardized echocardiographic images will be centrally analyzed using dedicated AI-based image segmentation and machine learning methods to quantify aortic valve calcification directly from TTE images. CT-derived aortic valve calcium score will serve as the reference standard. The primary objective is to derive and validate the Echo-AVCS score for identifying severe AS. Secondary objectives include determination of sex-specific diagnostic thresholds, correlation with CT calcium volume, association with symptoms and NYHA class, and evaluation of prognostic associations with aortic valve replacement, heart failure hospitalization, cardiovascular events, and mortality at 1-year follow-up.
Conditions
- Aortic Stenosis
- Chronic Coronary Syndrome
- Calcific Aortic Valve Disease
- Calcific Aortic Stenosis
Interventions
- DIAGNOSTIC_TEST
-
Echocardiography and Cardiac CT
This is a non-interventional, observational study in which all patients will undergo clinically indicated standard-of-care transthoracic echocardiography (TTE) and cardiac computed tomography (CT) with aortic valve calcium scoring. No investigational drug, device, or additional invasive procedure will be administered as part of the study. Echocardiographic images acquired during routine clinical practice will be anonymized and centrally analyzed using dedicated artificial intelligence-based software to derive and validate the echocardiographic aortic valve calcium score. Patient management, follow-up, and therapeutic decisions, including referral for aortic valve replacement, will remain entirely at the discretion of the treating physicians according to current clinical guidelines and standard practice.
Sponsors & Collaborators
-
Politecnico di Milano
collaborator OTHER -
Centro Cardiologico Monzino
collaborator OTHER -
I.R.C.C.S Ospedale Galeazzi-Sant'Ambrogio
collaborator OTHER -
University of Bologna
collaborator OTHER -
Azienda Ospedaliera "Sant'Andrea"
lead OTHER
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-03-01
- Primary Completion
- 2026-12-31
- Completion
- 2027-12-31
Countries
- Italy
Study Locations
More Related Trials
-
Point-of-Care Echocardiography in Patients With Known or Suspected Aortic Stenosis
NCT06717373 ·Status: COMPLETED ·Phase: NA
-
Valvular Aortic Stenosis Prognosis Study
NCT03628313 ·Status: RECRUITING
-
Pressure Gradient vs. Flow Relationships in Patients With Symptomatic Valvular Aortic Stenosis
NCT05580237 ·Status: COMPLETED
-
AI Assessment of Low-Gradient Aortic Stenosis Severity Based on Echocardiography
NCT07144189 ·Status: RECRUITING
-
Preoperative Assessment of Aortic Valve Stenosis and Coronary Artery Disease
NCT00767013 ·Status: UNKNOWN ·Phase: NA
-
Volume Challenge Added to DSE in the Diagnosis of Severe LFLGAS
NCT03617406 ·Status: COMPLETED ·Phase: NA
-
Stress Aortic Valve Index for Assessing Risk in Aortic Valve Stenosis Patients
NCT04514250 ·Status: ACTIVE_NOT_RECRUITING
-
Algorithms to Improve the Accuracy of the Echocardiographic Report
NCT05778500 ·Status: RECRUITING
-
In-vitro Benchmarking of Currently Available Heart Valve Prostheses for Surgical and Percutaneous Treatment of Aortic Stenosis With Small Annulus, Followed by In-vivo Validation
NCT06859255 ·Status: RECRUITING ·Phase: NA
-
AI-Enhanced Single-Lead ECG Screening for Coronary Stenosis
NCT07579624 ·Status: NOT_YET_RECRUITING
-
CoreValve Advance International Post Market Study
NCT01074658 ·Status: COMPLETED
-
Low Flow Low Gradient Aortic Stenosis Relevance of the (re)Search for a Contractile Reserve
NCT02727504 ·Status: COMPLETED
-
Safety and Efficacy Continued Access Study of the Medtronic CoreValve® System in the Treatment of Symptomatic Severe Aortic Stenosis in Very High Risk Subjects and High Risk Subjects Who Need Aortic Valve Replacement
NCT01531374 ·Status: COMPLETED ·Phase: NA
-
A Prospective, Multicenter, Single-arm Study to Evaluate a Transcatheter Aortic Valve System Safety and Efficacy for the Treatment of Patients With Severe Aortic Stenosis
NCT06136429 ·Status: RECRUITING ·Phase: NA
-
Progression of Ascending Aorta Diameters in Bicuspid Aortic Valve After Transcatheter or Surgical Replacement.
NCT05708118 ·Status: UNKNOWN
-
Randomized Study for the Optimal Treatment of Symptomatic Patients With Low Gradient Severe Aortic Valve Stenosis and Preserved Left Ventricular Ejection Fraction
NCT03667365 ·Status: TERMINATED ·Phase: NA
-
Aortic Stenosis Evaluated Via Modern Ballistocardiography and Seismocardiography
NCT04231201 ·Status: SUSPENDED
-
A Prospective, Multi-centre, Single Arm, Pivotal Clinical Study to Determine the Safety and Effectiveness of Crea Aortic Valve for Use as a Replacement Aortic Heart Valve
NCT07734025 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Dobutamine Stress Echocardiography in LF/LG Aortic Stenosis and Wild-type Transthyretin Amyloid Cardiomyopathy
NCT06372301 ·Status: COMPLETED ·Phase: NA
-
Aortic Stenosis - Prognosis, Risk and Outcomes
NCT06863883 ·Status: RECRUITING
-
COronary and MICrocirculatory Measurements in Patients With Aortic Valve Stenosis.
NCT04420325 ·Status: COMPLETED
-
Echo-Guided vs Fluoroscopy-Guided Transcatheter Aortic Valve Replacement in Patients With Aortic Stenosis(ECHO-TAVR)
NCT07317804 ·Status: NOT_YET_RECRUITING ·Phase: PHASE4
-
Microvascular Function in Patients Undergoing Transcatheter Aortic Valve Implant (TAVI) for Severe Symptomatic Aortic Stenosis: Association With Myocardial Fibrosis
NCT05326126 ·Status: COMPLETED ·Phase: NA
-
ADVANCE Direct Aortic Study
NCT01676727 ·Status: COMPLETED
-
Accuracy of Using 2D Transesophageal Echocardiography Compared to Balloon Sizing in Determining Valve Size During Transcatheter Aortic Valve Implantation
NCT04242225 ·Status: UNKNOWN