BBAP With CS Mapping Guidance
NCT07531368 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 40
Last updated 2026-04-15
Summary
Study Title
Efficacy and Safety of Coronary Sinus-Based Left Atrial Mapping for Guiding Atrial Lead Implantation Targeting Bachmann Bundle Capture in Cardiac Resynchronization Therapy Research Objectives
This study intends to use a 10-pole coronary sinus (CS) catheter to map left atrial activation time, assist in identifying the Bachmann bundle (BB) region, and further guide Bachmann bundle atrial pacing (BBAP) lead implantation. The anatomical relationship between the lead and the Bachmann bundle will be displayed by postoperative computed tomographic angiography (CTA), thereby verifying the efficacy and safety of this method in guiding BBAP surgical operations.
Study Endpoints
Primary Endpoint
* Technical success rate Key Secondary Endpoints
* Procedure time② Radiation dose③ Number of attempts for atrial lead screw-in during the operation: cumulative number of atrial lead implantation attempts during the operation④ Lead repositioning/reoperation rate⑤ Changes in electrical parameters (pacing threshold, lead impedance, intracardiac sensing) of the atrial lead at immediate postoperative, 1-month, 3-month, 6-month, 9-month, and 12-month follow-up⑥ Comparison of the effects of BBAP and right atrial appendage pacing (RAAP) on acute intraoperative hemodynamics⑦ Comparison of the differences in atrial high-rate (AHR) response in pacemaker programming data between BBAP and RAAP during 1-month, 3-month, 6-month, 9-month, and 12-month follow-up Safety Endpoints
* Major safety endpoint: Composite of severe complications② Minor safety endpoint: Incidence of specific adverse events Exploratory Endpoints
Health economics, electrophysiological indicators Secondary Efficacy Endpoints
To be further clarified according to the study design and clinical data collection.
Revisions Summary
Full expansion of all abbreviations on first occurrence CS = coronary sinus BB = Bachmann bundle BBAP = Bachmann bundle atrial pacing CTA = computed tomographic angiography RAAP = right atrial appendage pacing AHR = atrial high-rate Minor wording \& clarity improvements Specified "pacing threshold, lead impedance, intracardiac sensing" for clearer electrical parameter description Spelling/typo check No spelling errors, typos, or grammatical issues identified in the original text Consistent terminology maintained throughout
Conditions
Interventions
- DEVICE
-
CS mapping guidance
Selection of the optimal target site for atrial lead: In the 10-pole guided group, the electrode pair position with the lowest threshold + shortest LAAT time is selected as the lead implantation target;
- DEVICE
-
ECG guidance
in the control group, the implantation site meeting the Lustgarten standard is selected
Sponsors & Collaborators
-
Shanghai Zhongshan Hospital
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-05-01
- Primary Completion
- 2027-12-31
- Completion
- 2027-12-31
More Related Trials
-
A Study Assessing Arrhythmia Mapping With a Multi-Electrode Mapping Catheter
NCT07116525 ·Status: RECRUITING ·Phase: NA
-
Preload and Autonomic Responses With Cardiac Neuromodulation Therapy (CNT) (CS-06)
NCT04463121 ·Status: UNKNOWN ·Phase: NA
-
Metabolic Mapping and Cardiac Resynchronization
NCT03420833 ·Status: COMPLETED ·Phase: NA
-
Clinical Utility and Validation of the Rhythmia Mapping System for the Treatment of Cardiac Arrhythmias
NCT03094221 ·Status: COMPLETED
-
Clinical Study on the Efficiency of Rapid Arrhythmia Mapping Using EasyStars™ High Density Mapping Catheter Applications
NCT07079813 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Left Ventricular Lead Position in Cardiac Resynchronization Therapy
NCT00748735 ·Status: COMPLETED
-
Placement of CS/LV Pacing Leads With EnSite NavX Guidance
NCT00577187 ·Status: WITHDRAWN ·Phase: EARLY_PHASE1
-
Dipole Density Mapping in Supraventricular Tachycardia
NCT02469623 ·Status: COMPLETED ·Phase: NA
-
CardioInsight 3 - LBBB
NCT05556018 ·Status: RECRUITING ·Phase: NA
-
Septal Mapping And Resynchronisation Therapy- (SMART) Study
NCT04595305 ·Status: COMPLETED ·Phase: NA
-
Clinical Study of the EASYTRAK 3 Spiral Fixation Coronary Venous Bipolar Pace/Sense Lead
NCT00158938 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
The Fluoroless-CSP Trial Using Electroanatomic Mapping
NCT03903107 ·Status: COMPLETED ·Phase: NA
-
Image Location and Performance of Left Bundle Branch Pacing
NCT04119323 ·Status: COMPLETED
-
ElectrocardioGraphic Imaging During Left bUndle Branch Implant to valiDate Ecg Criteria
NCT06509763 ·Status: COMPLETED ·Phase: NA
-
Image Supported Lead Placement in CRT
NCT05053568 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Intrathoracic Bloodvolume Measurement by Contrast Enhanced Ultrasound: Validation of the Technique and Evaluation as a Measurement of Response to Cardiac Resynchronization Therapy: a Pilot Study
NCT01735838 ·Status: COMPLETED
-
Cardiac ResynchronizatiOn and arrhythmiaS Sensing Via the LEFT Bundle.
NCT05102227 ·Status: UNKNOWN
-
Mobile Cardiac Telemetry and Advanced Multi-Parameter Monitoring in PatientS Wearing a Novel Device With Biometric Based Medications Changes
NCT05505136 ·Status: COMPLETED
-
Predicting Response to CRT Using Body Surface ECG Mapping
NCT01831518 ·Status: COMPLETED ·Phase: NA
-
Electrocardiogram (ECG) Guided Peripherally Inserted Central Catheter (PICC) Placement
NCT00742053 ·Status: TERMINATED ·Phase: NA
-
Evaluation of ACUITY™ X4 Quadripolar Coronary Venous Leads and RELIANCE™ 4-FRONT Defibrillation Leads
NCT02071173 ·Status: COMPLETED ·Phase: NA
-
Angiography and Electrogram Guided Bachmann Bundle Pacing
NCT07110922 ·Status: RECRUITING ·Phase: NA
-
Comparison of Right Ventricular Septal and Right Ventricular Apical Pacing in Patients Receiving a CRT-D Device
NCT00833352 ·Status: COMPLETED ·Phase: NA
-
ECG Optimization of CRT: Evaluation of Mid-term Response
NCT01439529 ·Status: COMPLETED ·Phase: PHASE3
-
Detection of Heart Rhythm and BP With RhythmPadBP
NCT03813446 ·Status: COMPLETED