Comparison of Gastric Insufflation Volume Between LarySeal Pro and Ambu AuraGain Using Ultrasonography In Pediatric Patients Undergoing General Anesthesia With Controlled Ventilation.
NCT07451470 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 106
Last updated 2026-03-05
Summary
Gastric air insufflation during insertion of a laryngeal mask airway (LMA) is a known phenomenon and can have important clinical implications, especially in relation to: During positive pressure ventilation or improper insertion technique, air can be forced into the esophagus and stomach or LMAs do not fully seal the esophagus, so high ventilation pressures or incorrect placement may lead to gastric insufflation. Which may lead to Increased risk of regurgitation and aspiration, especially if the gastric contents reach the upper esophagus, Abdominal distension, which can reduce ventilation efficiency, nausea, vomiting, or delayed gastric emptying postoperatively which detected by Epigastric auscultation may reveal gurgling sounds during ventilation, Gastric ultrasound can visualize the extent of gastric insufflation and Capnography sometimes shows altered patterns if regurgitation begins . This complication prevented by:
* Use low-pressure, controlled ventilation (\<20 cmH₂O).
* Ensure proper size and positioning of the LMA.
* Use second-generation LMAs (like LarySealPro or Ambu AuraGain LMA) that have gastric drainage ports to relieve air.
Consider gastric ultrasound preoperatively to assess risk . (1)
Several studies have assessed the performance of Ambu AuraGain and LarySeal Pro individually or in comparison with other supraglottic airway devices. Ambu AuraGain, a second-generation device with a gastric drainage channel, has demonstrated high oropharyngeal leak pressures and ease of insertion, making it suitable for positive pressure ventilation. LarySeal Pro has also shown favorable results in terms of low airway resistance and effective sealing in adults. However, direct comparisons between these two devices are limited, especially regarding gastric insufflation volume measured by ultrasonography, which offers objective and quantitative assessment. Although some adult studies have evaluated AuraGain against devices like ProSeal or i-gel, there is a notable lack of pediatric studies directly comparing AuraGain and LarySeal Pro using gastric ultrasound techniques.(2) To date, no published randomized controlled trials have directly compared gastric insufflation volumes between Ambu AuraGain and LarySeal Pro using ultrasonography in pediatric patients under general anesthesia. This represents a critical gap in the literature, given the increased risk of aspiration in children and the growing use of ultrasound to evaluate perioperative gastric content.
Compared to Endotracheal intubation , SADs offer reported advantages such as simplicity in insertion, elimination of neuromuscular blocking agents, enhancement of spontaneous respiration, and avoidance of translaryngeal positioning accompanied by cardiovascular effects and close vocal cord contact. reduced rate of laryngospasm and a lower incidence of postoperative hoarse voice, coughing and sore throat. (3)
Despite this, the use of these device may be associated with various complications as regurgitation and aspiration of gastric contents, compression of vascular structures, trauma, and nerve injury.(4). The LMA can be a useful airway device in pediatric patients as well as adults, despite clear differences between the anatomy of the pediatric and adult airway. Sizes I, 2, and 2 1/2 are available for use in infants and children. In general, children require greater anesthetic depth prior to placement . The LMA can be placed successfully in children after either an inhalational or intravenous induction of anesthesia. (5) Ambu AuraGain and LarySeal Pro are designed with a cuff modified to improve the seal around the glottis and a drainage tube to provide a bypass channel for regurgitated gastric contents, prevent gastric insufflation, and allow the passage of a gastric tube. These features are designed to improve the safety of the mask and broaden its scope, especially when used with positive pressure ventilation.(6) Aim of the work The aim of the study is to compare the gastric insufflation volume between the LarySeal Pro Laryngeal Mask and Ambu AuraGain Laryngeal Mask in pediatric patients undergoing general anesthesia with controlled ventilation.
Objectives:
To assess and compare gastric insufflation volume between LarySeal Pro laryngeal mask and Ambu AuraGain laryngeal mask in pediatric patients using pelviabdominal ultrasound undergoing general anesthesia.
Hypothesis We hypothesize that LarySeal Pro laryngeal mask produce gastric insufflation volume less than Ambu AuraGain laryngeal mask in pediatric patients undergoing general anesthesia.
Conditions
- Gastric Insufflation
Interventions
- DEVICE
-
LarySeal Pro
Before induction of anesthesia, a gastric antrum ultrasound will be performed to assess gastric air volume by measuring the cross-sectional area of the gastric antrum in a supine position. The measurements will be taken between antral contractions to provide an accurate baseline value.In operation room, routine monitoring is established before induction of anesthesia . Either Group A, receiving the LarySeal Pro laryngeal mask Induction of general anesthesia will be achieved by inhalation induction by sevoflurane then securing IV access by proper sized cannula then all patients will received Fentanyl 1ug/kg, Propofol 2mg/kg and,tracium 0.5mg/kg. Mechanical ventilation will be employed be kept below \<15 (cmH2O) to avoid gastric insufflation.Postinsertion gastric (CSA) in the supine position will be measured using ultrasound after laryseal pro insertion. Then record readings pre and post insertion and post operative then compare between 2 devices regarding gastric antral volume.
- DEVICE
-
Ambu aura
: Before induction of anesthesia, a gastric antrum ultrasound will be performed to assess gastric air volume by measuring the cross-sectional area of the gastric antrum in a supine position. The measurements will be taken between antral contractions to provide an accurate baseline value.In operation room, routine monitoring is established before induction of anesthesia . Either Group A, receiving the LarySeal Pro laryngeal mask Induction of general anesthesia will be achieved by inhalation induction by sevoflurane then securing IV access by proper sized cannula then all patients will received Fentanyl 1ug/kg, Propofol 2mg/kg and,tracium 0.5mg/kg. Mechanical ventilation will be employed be kept below \<15 (cmH2O) to avoid gastric insufflation.Postinsertion gastric (CSA) in the supine position will be measured using ultrasound after laryseal pro insertion. Then record readings pre and post insertion and post operative then compare between 2 devices regarding gastric antral volume
Sponsors & Collaborators
-
Cairo University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- QUADRUPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 6 Years
- Max Age
- 10 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2025-10-01
- Primary Completion
- 2026-06-01
- Completion
- 2026-09-30
Countries
- Egypt
Study Locations
More Related Trials
-
Laryseal Pro LMA Versus Ambu Aura Gain LMA in Elective Ophthalmological Surgeries
NCT06140667 ·Status: COMPLETED ·Phase: NA
-
Ambu AuraGain Laryngeal Mask Airway and I-gel in Children
NCT03118245 ·Status: COMPLETED ·Phase: NA
-
Ambu Aura-i Laryngeal Mask Versus Air-Q Intubating Laryngeal Airway for Tracheal Intubation in Adults
NCT02226211 ·Status: UNKNOWN ·Phase: PHASE3
-
AuraGain Performance in Lateral Position
NCT05106478 ·Status: COMPLETED
-
Comparing Between Air-Q Intubating Laryngeal Airway and Ambu® AuraGain™
NCT03130413 ·Status: COMPLETED ·Phase: NA
-
A Comparison of the Ambu AuraGain Versus LMA Supreme in Children
NCT02380768 ·Status: COMPLETED ·Phase: NA
-
A Comparison Between the Intubating Laryngeal Tube Suction and the Ambu AuraGain
NCT02878005 ·Status: UNKNOWN ·Phase: NA
-
Assessment of Pediatric Challenging Airway
NCT06443424 ·Status: NOT_YET_RECRUITING
-
Volume Versus Pressure Ventilation on Lung Atelectasis
NCT06076395 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Comparison of Air QTM Intubating Airway Versus Ambu-Aura Intubating Laryngeal Mask
NCT04195035 ·Status: UNKNOWN ·Phase: NA
-
Prediction of Optimal Pediatric Endotracheal Tube Size "Aged Based Formula Versus Ultrasonography"
NCT03676387 ·Status: COMPLETED ·Phase: NA
-
Distance From the Glottis to the Grille in Children
NCT03156166 ·Status: COMPLETED ·Phase: NA
-
A Comparison Between the Intubating Laryngeal Tube Suction and the Ambu AuraGain
NCT05347680 ·Status: COMPLETED ·Phase: NA
-
A Study Between the Laryngeal Tube Suction-Disposable and the Ambu AuraGain in Pediatric Patients
NCT02977559 ·Status: UNKNOWN ·Phase: NA
-
Ambu Aura GainTM Guided vs Non Guided in Edentulous Ambu Aura GainTM Without Gastric Tube in Endontolous Patient
NCT03933644 ·Status: COMPLETED ·Phase: NA
-
The Effect Of I-Gel And Ambu Aura-I Use On Laryngofaryngeal Mucosa
NCT04062747 ·Status: UNKNOWN ·Phase: NA
-
Comparing the Effect of LTS and Air-Q sp3G LMA Use on Gastric Insufflation Using Ultrasound
NCT07196137 ·Status: COMPLETED
-
Comparison Between Three Supraglottic Airway Devices ProSeal Laryngeal Mask Airway, Air-Q LMA and Ambu AuraGain
NCT04045899 ·Status: COMPLETED ·Phase: NA
-
Gastric Insufflation and Laryngeal Mask Airway
NCT02097771 ·Status: UNKNOWN ·Phase: NA
-
Ambu® Auragain™ as a Conduit for Intubation in Paediatrics
NCT03955094 ·Status: COMPLETED ·Phase: NA
-
A Randomized Comparison of Pediatric I-gel, Air-Q With Classic Laryngeal Mask Airway
NCT02757820 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Comparison of Gastric Volume in I-gel and ProSeal Laryngeal Mask Airways
NCT07138092 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Intubation on a Paediatric Manikin by Emergency Staff: a Comparison of Airtraq and Glidescope
NCT02478203 ·Status: COMPLETED ·Phase: NA
-
A Randomised Controlled Trial to Compare Two Supraglottic Airway Devices (Ambu AuraGain vs Air Q-3) in Terms of Performance Characteristics.
NCT06914453 ·Status: COMPLETED ·Phase: NA
-
I-Gel vs Ambu Laryngeal Mask Airways in Infants and Children Undergoing Surgical Procedures
NCT02938039 ·Status: COMPLETED ·Phase: NA