Use of a Novel Camera to Check the Bowel After Polyp or Tumour Removal
NCT07341126 · Status: NOT_YET_RECRUITING · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2026-02-06
Summary
1.1 Polyps or tumours in the lower part of the bowel (rectum) can be removed using instruments inserted through the bottom which avoids major surgery and the possibility of a stoma bag (colostomy). Afterwards, it is important to check the area with regular camera tests. If checks are delayed, re-growths could be serious and may be untreatable. COVID and other factors have led to long waiting lists for camera checks and in NHS Lothian around 20% of all camera checks are done more than 6 months late.
The investigators want to try a new camera and approach that would allow us to reduce waiting lists. Using a short camera called a 'rectoscope' to check the lower bowel has already been shown to be safe, comfortable and acceptable to patients with other conditions. In fact, patients are unlikely to feel or realise any difference between the rectoscope and standard camera tests.
The investigators want to show that this 'rectoscope' can be safely used in the outpatient clinic with an enema (suppository) instead of strong bowel medicine taken by mouth the day before. This would mean the camera checks happen on time and would reduce waiting lists for other important tests.
The investigators will include 30 patients across three stages of our study. In the first set of patients, the investigators will use the rectoscope alongside the usual endoscope in the endoscopy room using the usual oral bowel medicine. This stage will check the rectoscope is acceptable to the patient and the doctor. In the next 10 patients the investigators will use a suppository instead of oral bowel medicine still using both cameras. Finally, the investigators will use the rectoscope in the outpatient clinic with an suppository to show this is an easy, effective and acceptable way to deliver timely camera checks.
Conditions
- Bowel Cancer
- Polyp Rectal
- Rectal Cancer
- Rectal Adenocarcinoma
- Rectal Adenoma
Interventions
- DIAGNOSTIC_TEST
-
LumenEye X1 digital rectoscope
The LumenEye X1 is a novel digital rectoscope that introduces digital HD imaging and improved ergonomics to conventional rigid sigmoidoscopy.
Sponsors & Collaborators
-
NHS Lothian
collaborator OTHER_GOV -
University of Edinburgh
lead OTHER
Eligibility
- Min Age
- 16 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2026-04-01
- Primary Completion
- 2027-04-01
- Completion
- 2027-05-01
- FDA Device
- Yes
Countries
- United Kingdom
Study Locations
More Related Trials
-
Using AI-assisted Optical Polyp Diagnosis for Diminutive Colorectal Polyps
NCT06059378 ·Status: RECRUITING ·Phase: NA
-
Real-time AI-assisted Endocyroscopy for the Diagnosis of Colorectal Lesions
NCT06791395 ·Status: COMPLETED
-
Retroview™ Colonoscope and Lesion Detection Rate
NCT03155165 ·Status: COMPLETED
-
Computer Aided Diagnosis (CADx) for Colorectal Polyps Resect-and-Discard Strategy
NCT06062095 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Real-World Validation of an Artificial Intelligence Characterization Support (CADx) System
NCT05034185 ·Status: COMPLETED
-
Endocytoscopy and Colorectal Neoplasia
NCT02324374 ·Status: COMPLETED ·Phase: NA
-
Endocuff Adenoma Detection Rate Pilot Study
NCT01761097 ·Status: UNKNOWN ·Phase: NA
-
Detect InSpect ChAracterise Resect and Discard 2
NCT01603927 ·Status: UNKNOWN
-
Endoscopic Optical Coherence Tomography for Screening and Diagnosis of Colorectal Precancerous and Malignant Polyps
NCT05179837 ·Status: TERMINATED ·Phase: NA
-
AmplifEYE Colonoscopy vs Standard Colonoscopy
NCT03814369 ·Status: COMPLETED ·Phase: NA
-
Real-Time CAD for Colonic Neoplasia: A RCT
NCT05963724 ·Status: COMPLETED ·Phase: NA
-
BowelScope: Accuracy of Detection Using ENdocuff Optimisation of Mucosal Abnormalities
NCT03072472 ·Status: COMPLETED ·Phase: NA
-
Endoscopic Assessment of Polyp Histology
NCT01297712 ·Status: TERMINATED ·Phase: NA
-
High Definition Endoscopy and Virtual Chromoendoscopy Versus Standard Resolution Endoscopy in Detection of Colon Polyps
NCT03243669 ·Status: COMPLETED ·Phase: NA
-
The Influence of Artificial Intelligence (AI )Assisted Polyp Detection (Discovery System) on Visual Gaze Patterns During Real-time Colonoscopy
NCT05619614 ·Status: COMPLETED
-
Artificial Intelligence in the Characterization of Colorectal Polyps
NCT04749277 ·Status: COMPLETED
-
AI-assisted Detection of Missed Colonic Polyps
NCT04227795 ·Status: COMPLETED ·Phase: NA
-
NBI Versus White Light Endoscopy for Optical Characterization of Neoplastic Polyps in the Colorectum
NCT03679429 ·Status: UNKNOWN
-
Artificial Intelligence Identifying Polyps in Real-world Colonoscopy
NCT03761771 ·Status: COMPLETED
-
Computer Assisted Measurement of Colorectal Polyps
NCT02970760 ·Status: UNKNOWN
-
Computer Assisted Optical Assessment of Small Colorectal Polyps
NCT02522702 ·Status: UNKNOWN
-
Ultrasound and Photoacoustic Imaging for Enhanced Differential Diagnosis of Rectal Cancer
NCT04339374 ·Status: RECRUITING ·Phase: NA
-
AI in Predicting Polyp Pathology and Endoscopic Classification
NCT06773832 ·Status: RECRUITING
-
Clinical Study on the Application of a Specimen Retrieving Bag to Reduce the Polyp Fragmentation Rate
NCT05189912 ·Status: COMPLETED ·Phase: NA
-
Endoscopic Full Thickness Resection Versus Standard Therapy of the Colorectal Neoplasia
NCT03868605 ·Status: UNKNOWN ·Phase: NA