Impact of Infusion Line Change Frequency on Infectious Complications Related to Central Venous Catheters in the ICU - A Randomized Controlled Trial

NCT07183592 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 2830

Last updated 2026-05-13

No results posted yet for this study

Summary

In the intensive care unit, patients' care and secure drugs administration require a central venous catheter. These invasive devices can lead to complications, particularly infections. Most preventive recommendations focus on catheter insertion, line handling, and dressings. Few recommendations adress catheter dwell time, which is certainly the main source of infection. Part of the prevention strategy is the regular and systematic replacement of infusion sets , as they may become contaminated during use, mainly through the hands of healthcare professionals. Prolonged use increases the risk of infection. Infusion lines changes involve disconnecting the old sets, discarding infusion devices containing drug residues, and replacing them with new sterile devices.

Current international guidelines recommend replacing these sets every 4 days, and the Center for Disease Control and Prevention recommends not exceeding 7 days. Replacing these devices requires the time of qualified nurses, numerous sterile medical devices, and medications. In addition to the intended effect on infection prevention, the procedure has impacts on workload and costs.

The objective of the study is to demonstrate that changing infusion set every 7 days does not increase the rate of central venous catheters related infections compared with changing infusion set every 4 days.

Conditions

  • Intensive Care (ICU)
  • Central Venous Catheter Related Infections
  • Critical Care Nursing
  • Catheter-associated Bloodstream Infections (CLABSI)
  • Nursing Workload

Interventions

PROCEDURE

7-day Infusion set replacement

7-day infusion set replacement (Experimental arm) In this group, the infusion sets (the tubes and connectors used to deliver medications through the central venous catheter) will be changed once a week, every 7 days. During each replacement, all sets will be disconnected and replaced with new sterile ones.

PROCEDURE

4-day infusion set replacement

4-day infusion set replacement (Active comparator arm) In this group, the infusion sets will be changed every 4 days, which reflects the most common international recommendation. The procedure is the same: all sets connected to the central venous catheter will be replaced with new sterile ones. This strategy represents the current standard of care and will serve as the comparison for the 7-day approach.

Sponsors & Collaborators

  • University Hospital, Angers

    lead OTHER_GOV

Principal Investigators

  • Carole Haubertin · University Hospital, Angers

Study Design

Allocation
RANDOMIZED
Purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2026-05-12
Primary Completion
2028-05-31
Completion
2028-12-31

Countries

  • France

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT07183592 on ClinicalTrials.gov