Comparing Two Methods to Measure Nasogastric Tube Length
NCT06982495 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 220
Last updated 2025-05-29
Summary
The goal of this clinical trial is to learn if using a novel nasogastric tube assisted placement system (NCKU-NG system) can more accurately place the nasogastric tube at the optimal position in the stomach compared to conventional blind insertion techniques in adult inpatients requiring nasogastric tube placement. The main questions it aims to answer are:
* Does the NCKU-NG system improve the accuracy of nasogastric tube placement at the optimal gastric position compared to standard blind insertion?
* Does the NCKU-NG system reduce the rate of misplacement (such as entry into the airway or inadequate gastric depth), number of repeated attempts, and complication rate compared to the conventional method?
* Can estimation of nasogastric tube length using the NCKU-NG system provide a more reliable reference than external measurement or X-ray?
Researchers will compare patients randomized to nasogastric tube insertion with the NCKU-NG system (intervention arm) versus conventional blind insertion following standard external measurement methods (control arm) to see if the NCKU-NG system improves placement accuracy and reduces adverse events.
Participants will:
* Be randomized to one of two groups:
* Intervention group: Receive nasogastric tube insertion using the NCKU-NG system (video-assisted real-time visualization, with active confirmation of passage through the esophagogastric junction and final position in the stomach based on sidehole location).
* Control group: Receive traditional nasogastric tube blind bedside insertion based on standard measurement (eg. Nose-Earlobe-Xiphoid + 10 cm).
* All procedures will use the same material nasogastric tube (16 French polyurethane radiopaque tube).
* Undergo confirmation of tube position by X-ray within 8 hours post-insertion for both groups.
* Have the following outcomes assessed:
* Placement accuracy (percentage of tubes placed at optimal predefined gastric position)
* Number of placement attempts and failures
* Rate of inadvertent airway or inadequate placement
* Incidence of complications (e.g., aspiration, pneumothorax, gastrointestinal tract injury)
* Correlation between video-assisted measurement and X-ray estimation of intragastric length
Conditions
- Intubation, Nasogastric
- Intubation Intraesophageal
- Intubation Depth
- Intubation Times
- Intubation; Complication
Interventions
- DEVICE
-
NCKU-NG system
Nasogastric tube insertion with a novel nasogastric tube assisted placement system (NCKU-NG system)
- OTHER
-
Conventional blind insertion
Conventional blind insertion following standard external measurement methods (eg. Nose-Earlobe-Xiphoid + 10 cm)
Sponsors & Collaborators
-
National Cheng-Kung University Hospital
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- TRIPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-06-30
- Primary Completion
- 2025-12-31
- Completion
- 2025-12-31
More Related Trials
-
Is Ultrasound Comparable to Chest X-ray in Verification of Intensive Care Patients Enteral Feeding Tube Positioning.
NCT06000384 ·Status: COMPLETED
-
Accuracy of Ultrasonography in Confirming Correct Positioning of Nasogastric Tube in the Intensive Care Setting
NCT06693219 ·Status: COMPLETED ·Phase: NA
-
Nasogastric Tube Insertion Using Cook Airway Exchange Catheter in Anesthetized Patients
NCT01783366 ·Status: UNKNOWN ·Phase: NA
-
Ultrasound for Confirmation of Gastric Tube Placement in Critically Ill Patients Under Invasive Mechanical Ventilation
NCT04795895 ·Status: TERMINATED ·Phase: NA
-
Ultrasound to Check the Position of the Nasogastric Tube
NCT06635915 ·Status: RECRUITING ·Phase: NA
-
Confirmation of Nasogastric Tube Placement Via Ultrasonography
NCT00941772 ·Status: COMPLETED ·Phase: NA
-
Nasogastric Tube Placement on Intubated Patient: Two-Finger Method vs Reverse Sellick's Maneuver
NCT03134287 ·Status: COMPLETED ·Phase: NA
-
Comparison of Three Methods for NG Tube Placement
NCT03699306 ·Status: COMPLETED ·Phase: NA
-
Verification of Correct Positioning of a Gastric Tube by Ultrasonography
NCT02866123 ·Status: TERMINATED ·Phase: NA
-
Effect of Evidence-Based Skin Care and Hydrocolloid Dressing in the Prevention of Nasogastric-Related Pressure Injury
NCT04682925 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Nasojejunal Enteral Feeding in Critically Ill Patients.
NCT00256048 ·Status: COMPLETED ·Phase: NA
-
Ultrasonography Confirmation of Feeding Tube Placement
NCT05307900 ·Status: COMPLETED ·Phase: NA
-
Performance of the NGPOD® Device in Verifying the Correct Position in the Stomach of the Naso- or Oro- Gastric Tube in Intensive Care.
NCT06316986 ·Status: COMPLETED ·Phase: NA
-
Feeding Tube Attachment Device Versus Conventional Fixation and Its Impact on Accidental Exit of Enteral Feeding Tubes
NCT03262493 ·Status: COMPLETED ·Phase: NA
-
Orogastric Versus Nasogastric Intubation
NCT03670238 ·Status: COMPLETED ·Phase: NA
-
Nasal Bridle Versus Nasal Patch for Fixation of Nasoenteral Feeding Tubes
NCT05694299 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of Jejunal Placement of Enteral Feeding Tubes
NCT00500851 ·Status: COMPLETED ·Phase: NA
-
Ultrasound Evaluation of Endotracheal Tube Depth
NCT01649882 ·Status: UNKNOWN ·Phase: NA
-
End-Tidal CO2 (etCO2) and pH in the Correct Naso-gastric Tube Placement
NCT03934515 ·Status: COMPLETED
-
The Effect of Three Different Nasogastric Tube Fixation Materials on Pressure Injury
NCT06819800 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Gastric Tube Guide to Place Orogastric Tubes
NCT02925052 ·Status: COMPLETED ·Phase: NA
-
Facilitation of NGT Insertion
NCT02764632 ·Status: COMPLETED ·Phase: NA
-
Nasal Bridles and Repeat Endoscopic Procedures for Endoscopic Nasoenteric Tubes
NCT03966157 ·Status: COMPLETED ·Phase: NA
-
Nasogastric/Orogastric Tube Placement Verification Study Using RightSpot pH Indicator to Verify Gastric Acidity
NCT01561729 ·Status: UNKNOWN ·Phase: NA
-
Entarik Feeding Tube System Placement in Adult ICU
NCT05884216 ·Status: TERMINATED ·Phase: NA