Verification of Correct Positioning of a Gastric Tube by Ultrasonography
NCT02866123 · Status: TERMINATED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 19
Last updated 2016-08-15
Summary
There are several ways to verify the correct positioning of a gastric tube. Radiography is considered the reference method. The use of ultrasonography could diminish the number of radiographies necessary. The hypothesis of this research is that gastric ultrasonography performed during insertion of the tube is a reliable examination to check the correct positioning of gastric tubes in intensive care.
Conditions
- Insertion of a Nasogastric Tube
- Intubated Patient
- Patients Hospitalized in the Surgery Intensive Care Unit
Interventions
- OTHER
-
ultrasonography
- RADIATION
-
pulmonary radiography
Sponsors & Collaborators
-
Centre Hospitalier Universitaire Dijon
lead OTHER
Study Design
- Allocation
- NA
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-01-31
- Primary Completion
- 2015-05-31
Countries
- France
Study Locations
More Related Trials
-
Ultrasound for Confirmation of Gastric Tube Placement in Critically Ill Patients Under Invasive Mechanical Ventilation
NCT04795895 ·Status: TERMINATED ·Phase: NA
-
Bedside Ultrasound Assessment of Feeding Tube Position in the Intensive Care Unit
NCT06077617 ·Status: RECRUITING
-
Ultrasonography in Confirming Proper Position of Endotracheal Tube
NCT01373437 ·Status: COMPLETED
-
Ultrasonography Confirmation of Feeding Tube Placement
NCT05307900 ·Status: COMPLETED ·Phase: NA
-
Ultrasound-Guided Peripheral Intravenous Access by Critical Nurses.
NCT02285712 ·Status: COMPLETED ·Phase: NA
-
Blind Gastric Tube Placement: Incidence of Malposition Confirmed by Ultrasonography
NCT03430908 ·Status: COMPLETED
-
Ultrasound Evaluation of Endotracheal Tube Depth
NCT01649882 ·Status: UNKNOWN ·Phase: NA
-
Orogastric Versus Nasogastric Intubation
NCT03670238 ·Status: COMPLETED ·Phase: NA
-
The Application of Neck Ultrasound in the Assessment of Peripherally Inserted Central Catheter (PICC) Tip Position
NCT00565877 ·Status: COMPLETED ·Phase: NA
-
Two Bedside Ultrasound Techniques and Standard Methods for Confirmation of Endotracheal Tube Insertion in Intensive Care Patients
NCT06510387 ·Status: RECRUITING
-
Impact of the Choice of Gastric Tube Placement Sites on the Incidence of Ventilator Associated Pneumonia
NCT05915663 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
SUBclavian Central Venous Catheters Guidance and Examination by UltraSound
NCT01888094 ·Status: COMPLETED ·Phase: PHASE2/PHASE3
-
Ultrasonography Versus Capnography in Detecting Endotracheal Tube Placement During Intubation in a Tertiary Hospital.
NCT04316988 ·Status: COMPLETED
-
Ultrasound Meal Accommodation Test for Enteral Feeding in the Critically Ill
NCT03851354 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Accuracy of Capnography in Nasogastric Tube Placement
NCT05817864 ·Status: RECRUITING
-
Performance of the NGPOD® Device in Verifying the Correct Position in the Stomach of the Naso- or Oro- Gastric Tube in Intensive Care.
NCT06316986 ·Status: COMPLETED ·Phase: NA
-
Central Venous Catheter Placement With Thoracic Ultrasound and Intracavity ECG Positioning
NCT07291869 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of Three Methods for NG Tube Placement
NCT03699306 ·Status: COMPLETED ·Phase: NA
-
Study of the Effectiveness of Central Line Placement Using an Ultraportable Ultrasound Device
NCT05692310 ·Status: UNKNOWN ·Phase: NA
-
Ultrasound Evaluation of the Vascular Anatomy of the Neck to Minimize the Accidental Risk of Vascular Puncture During Percutaneous Tracheostomy
NCT06002178 ·Status: COMPLETED
-
Supraclavicular Fossa US View for Catheter Positioning in Right Subclavian Central Venous Catheterization
NCT03812757 ·Status: COMPLETED
-
Comparison of Different Methods of Nasogastric Tube Insertion in Anesthetized and Intubated Patients
NCT02557204 ·Status: COMPLETED ·Phase: NA
-
Nasogastric Tube Insertion Using Cook Airway Exchange Catheter in Anesthetized Patients
NCT01783366 ·Status: UNKNOWN ·Phase: NA
-
Nasogastric Tube Placement on Intubated Patient: Two-Finger Method vs Reverse Sellick's Maneuver
NCT03134287 ·Status: COMPLETED ·Phase: NA
-
Ultrasound to Investigate Tip Dislodgment of Epicutaneous-caval Catheter.
NCT06438289 ·Status: COMPLETED