Performance of the NGPOD® Device in Verifying the Correct Position in the Stomach of the Naso- or Oro- Gastric Tube in Intensive Care.
NCT06316986 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2025-08-22
Summary
In the Intensive Care Unit (ICU), scientific societies recommend starting enteral nutrition within 48 hours of admission, if oral nutrition is not available, in order to limit undernutrition. In patients who are sedated, have swallowing problems or cannot ensure adequate caloric intake, it is essential to insert a feeding tube, usually a nasogastric or orogastric tube for the first few weeks.
Placement of a naso- or oro-gastric tube in the intensive care unit is a frequent procedure, and considered to be straightforward. It is usually performed blindly, at the patient's bedside, by a nurse or doctor, according to a departmental protocol or the recommendations of learned societies.
Nevertheless, a number of complications have been reported with naso- or oro-gastric tubes, linked in particular to a route outside the digestive tract : malpositioning/coiling of the tube, epistaxis, sinusitis. The most frequent and potentially severe complications are malpositions in the tracheobronchial tree.
Radiographic control is currently considered in France and by certain learned societies to be the reference method for verifying correct positioning of the probe in the stomach (at the prepyloric antral level). However, thoracic radiography has a number of drawbacks : In intensive care risk of accidental displacement of other medical devices,irradiation, difficulty of interpretation, delay in obtaining the image, time-consuming work for qualified personnel.
An alternative technique using the NGPOD device is proposed as a method of checking the correct positioning of the probe in the stomach. This system enables immediate, rapid (15 seconds), simple and automatic testing at the patient's bedside. The device provides a visual indication of the pH detected at the tip of the gastric tube. The test result is given in binary form: Yes (green signal, probe in stomach) / No (red signal, probe incorrectly positioned).
Study hypothesis and prospects: To make an initial estimate of the sensitivity and specificity of the NGPOD system for checking the positioning of the naso- or oro-gastric tube in the stomach, compared with the recognized gold standard, the chest X-ray.
Conditions
- Intensive Care
- Nutrition
Interventions
- DIAGNOSTIC_TEST
-
pH indication with NGPOD
The NGPOD sensor is inserted into the naso- or oro-gastric tube, then reconnected to the NGPOD handheld device, and the pH measurement is taken within 15 seconds. When the 15 seconds have elapsed, the pH button is pressed. If the green LED lights up and the pH indicates a value \< 5.5, the sensor tip is in a pH environment associated with the stomach. If the red LED lights up, the sensor tip is in a pH environment NOT associated with the stomach.
Sponsors & Collaborators
-
Fondation Hôpital Saint-Joseph
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- PREVENTION
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-05-07
- Primary Completion
- 2024-12-27
- Completion
- 2025-04-01
Countries
- France
Study Locations
More Related Trials
-
Impact of the Choice of Gastric Tube Placement Sites on the Incidence of Ventilator Associated Pneumonia
NCT05915663 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison of Three Methods for NG Tube Placement
NCT03699306 ·Status: COMPLETED ·Phase: NA
-
Nasogastric/Orogastric Tube Placement Verification Study Using RightSpot pH Indicator to Verify Gastric Acidity
NCT01561729 ·Status: UNKNOWN ·Phase: NA
-
Gastric Ultrasound Feeding Tube Placement Confirmation Study
NCT06595537 ·Status: RECRUITING
-
Bedside Ultrasound Assessment of Feeding Tube Position in the Intensive Care Unit
NCT06077617 ·Status: RECRUITING
-
Comparison of RightSpot pH Indicator & RightLevel pH Detector With X-Ray Verification for FT or G-Tube Placement
NCT01825564 ·Status: TERMINATED
-
Feeding Tube Attachment Device Versus Conventional Fixation and Its Impact on Accidental Exit of Enteral Feeding Tubes
NCT03262493 ·Status: COMPLETED ·Phase: NA
-
Ultrasound to Check the Position of the Nasogastric Tube
NCT06635915 ·Status: RECRUITING ·Phase: NA
-
End-Tidal CO2 (etCO2) and pH in the Correct Naso-gastric Tube Placement
NCT03934515 ·Status: COMPLETED
-
Is Ultrasound Comparable to Chest X-ray in Verification of Intensive Care Patients Enteral Feeding Tube Positioning.
NCT06000384 ·Status: COMPLETED
-
Comparison of Percutaneous Image-guided Gastrostomies
NCT02053428 ·Status: COMPLETED ·Phase: NA
-
An Observational Study Examining Adverse Events and Effectiveness of the Nasal Bridle Securement Device in ICU Patients
NCT03387358 ·Status: UNKNOWN
-
A Modified Method for Blind Bedside Placement of Post-pyloric Feeding Tube.
NCT04608071 ·Status: COMPLETED
-
Confirmation of Nasogastric Tube Placement Via Ultrasonography
NCT00941772 ·Status: COMPLETED ·Phase: NA
-
Using Magnetic Field Tracking to Confirm Nasogastric Tube Placement at Point of Care
NCT05204901 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Two Methods of Jejunal Placement of Enteral Feeding Tubes in Critically Ill Patients
NCT00807287 ·Status: COMPLETED ·Phase: NA
-
Central Venous Catheter Placement With Thoracic Ultrasound and Intracavity ECG Positioning
NCT07291869 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparing Two Methods to Measure Nasogastric Tube Length
NCT06982495 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Ultrasound Meal Accommodation Test for Enteral Feeding in the Critically Ill
NCT03851354 ·Status: COMPLETED ·Phase: NA
-
Facilitation of NGT Insertion
NCT02764632 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Jejunal Placement of Enteral Feeding Tubes
NCT00500851 ·Status: COMPLETED ·Phase: NA
-
The Early Nasojejunal Tube to Meet Energy Requirements in Intensive Care (ENTERIC) Study
NCT00163813 ·Status: UNKNOWN ·Phase: NA
-
Efficacy of Nasojejunal Enteral Feeding in Critically Ill Patients.
NCT00256048 ·Status: COMPLETED ·Phase: NA
-
Ultrasound-Guided Peripheral Intravenous Access by Critical Nurses.
NCT02285712 ·Status: COMPLETED ·Phase: NA
-
Ultra-portable Ultrasound vs. Standard Ultrasound to Help Place a Peripheral Catheter in Patients at Risk of Difficult Puncture
NCT06296264 ·Status: RECRUITING ·Phase: NA