Performance of the NGPOD® Device in Verifying the Correct Position in the Stomach of the Naso- or Oro- Gastric Tube in Intensive Care.

NCT06316986 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50

Last updated 2025-08-22

No results posted yet for this study

Summary

In the Intensive Care Unit (ICU), scientific societies recommend starting enteral nutrition within 48 hours of admission, if oral nutrition is not available, in order to limit undernutrition. In patients who are sedated, have swallowing problems or cannot ensure adequate caloric intake, it is essential to insert a feeding tube, usually a nasogastric or orogastric tube for the first few weeks.

Placement of a naso- or oro-gastric tube in the intensive care unit is a frequent procedure, and considered to be straightforward. It is usually performed blindly, at the patient's bedside, by a nurse or doctor, according to a departmental protocol or the recommendations of learned societies.

Nevertheless, a number of complications have been reported with naso- or oro-gastric tubes, linked in particular to a route outside the digestive tract : malpositioning/coiling of the tube, epistaxis, sinusitis. The most frequent and potentially severe complications are malpositions in the tracheobronchial tree.

Radiographic control is currently considered in France and by certain learned societies to be the reference method for verifying correct positioning of the probe in the stomach (at the prepyloric antral level). However, thoracic radiography has a number of drawbacks : In intensive care risk of accidental displacement of other medical devices,irradiation, difficulty of interpretation, delay in obtaining the image, time-consuming work for qualified personnel.

An alternative technique using the NGPOD device is proposed as a method of checking the correct positioning of the probe in the stomach. This system enables immediate, rapid (15 seconds), simple and automatic testing at the patient's bedside. The device provides a visual indication of the pH detected at the tip of the gastric tube. The test result is given in binary form: Yes (green signal, probe in stomach) / No (red signal, probe incorrectly positioned).

Study hypothesis and prospects: To make an initial estimate of the sensitivity and specificity of the NGPOD system for checking the positioning of the naso- or oro-gastric tube in the stomach, compared with the recognized gold standard, the chest X-ray.

Conditions

  • Intensive Care
  • Nutrition

Interventions

DIAGNOSTIC_TEST

pH indication with NGPOD

The NGPOD sensor is inserted into the naso- or oro-gastric tube, then reconnected to the NGPOD handheld device, and the pH measurement is taken within 15 seconds. When the 15 seconds have elapsed, the pH button is pressed. If the green LED lights up and the pH indicates a value \< 5.5, the sensor tip is in a pH environment associated with the stomach. If the red LED lights up, the sensor tip is in a pH environment NOT associated with the stomach.

Sponsors & Collaborators

  • Fondation Hôpital Saint-Joseph

    lead OTHER

Study Design

Allocation
NA
Purpose
PREVENTION
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2024-05-07
Primary Completion
2024-12-27
Completion
2025-04-01

Countries

  • France

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT06316986 on ClinicalTrials.gov