A Head-to-Head Comparison of A New Perfusion Tracer, 99mTc-4BOH vs. 13N-NH3 to Evaluate Diagnostic Efficacy of Ischemic Heart Disease
NCT06980194 · Status: NOT_YET_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 300
Last updated 2025-05-20
Summary
The objective of the study is to assess the diagnostic efficacy (specificity and sensitivity) of 99mTc-4BOH SPECT myocardial perfusion imaging (MPI) compared to 13N-ammonia PET MPI in the detection of significant coronary artery disease (CAD) as defined by invasive coronary angiography (ICA).
Conditions
Interventions
- DIAGNOSTIC_TEST
-
99mTc-4BOH SPECT myocardial perfusion imaging
Participants undergo myocardial perfusion imaging using the investigational radiotracer 99mTc-4BOH with SPECT. Imaging is performed according to a standardized protocol. Each participant receives both this SPECT imaging and a PET imaging procedure using 13N-ammonia, in a randomized sequence, within a 7-day interval.
- DIAGNOSTIC_TEST
-
13N-ammonia PET myocardial perfusion imaging
Participants undergo myocardial perfusion imaging using 13N-ammonia with PET as the active comparator. This procedure is performed according to standard clinical protocols. Each participant also receives 99mTc-4BOH SPECT imaging in a randomized sequence, with both tests completed within a 7-day window.
Sponsors & Collaborators
-
China National Center for Cardiovascular Diseases
lead OTHER_GOV
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-08-01
- Primary Completion
- 2027-12-30
- Completion
- 2027-12-30
More Related Trials
-
Effectiveness Study of Single Photon Emission Computed Tomography (SPECT) Versus Positron Emission Tomography (PET) Myocardial Perfusion Imaging
NCT00976053 ·Status: COMPLETED ·Phase: PHASE4
-
Stress and Rest Myocardial Tomoscintigraphies Using Mono- or Double-isotope Protocol With a Semiconductor Camera
NCT02869126 ·Status: COMPLETED ·Phase: NA
-
Prognostic Value of Stress SPECT Myocardial Perfusion Imaging With Half Dose 99mTc-Tetrofosmin
NCT02019212 ·Status: COMPLETED
-
Comparison of Cardiac Computed Tomography for the Detection of Coronary Artery Disease With Nuclear Stress Test
NCT00352937 ·Status: COMPLETED
-
Cadmium-zinc-telluride (CZT) Imaging of Myocardial Blood Flow (MBF) (SPECT MBF)
NCT02280941 ·Status: COMPLETED ·Phase: NA
-
Comparison of Diagnostic Rest/Stress SPECT Results for Patients With Myocardial Ischemia and Infarction Using Myoview in Both Single and Dual Isotope Acquisition Approaches
NCT00381316 ·Status: COMPLETED ·Phase: PHASE4
-
Stress Adenosine Cardiac Magnetic Resonance (MR) Comparison With Single Photon Emission Computed Tomography (SPECT) Imaging
NCT00864591 ·Status: UNKNOWN
-
Multi-center Trial of SPECT Myocardial Blood Flow Quantitation for Detection of Coronary Artery Disease
NCT03637725 ·Status: COMPLETED
-
PET/CT Quantitative Assessment of Myocardial Blood Flow Changes in Oncologic Patients Receiving Checkpoint Inhibitor Therapy
NCT04538950 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Efficiency and Outcomes of Stress-Only Anger and D-SPECT Stress-Only SPECT MPI
NCT01373944 ·Status: COMPLETED
-
Determination of Coronary Flow Reserve by Dynamic Myocardial Perfusion Scintigraphy
NCT03326167 ·Status: TERMINATED
-
Validation of a Single Rest-Stress Imaging Protocol for Myocardial Perfusion Imaging
NCT03265535 ·Status: UNKNOWN
-
Impact of Stress CT Myocardial Perfusion on Downstream Resources and Prognosis
NCT03976921 ·Status: UNKNOWN ·Phase: NA
-
Initial CT Perfusion-Guided Strategy for Suspected NSTEMI
NCT06689267 ·Status: COMPLETED ·Phase: NA
-
Myocardial Flow Reserve and 99mTc-DTPA Cardiac Dynamic SPECT
NCT02844686 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Rubidium PET and SPECT With CZT Crystals for Detection of Myocardial Ischemia in Overweighed Patients and Women
NCT01679886 ·Status: COMPLETED ·Phase: NA
-
Stress Testing Compared to Coronary Computed Tomographic Angiography in Patients With Suspected Coronary Artery Disease
NCT01368770 ·Status: COMPLETED ·Phase: PHASE3
-
Dynamic Cardiac SPECT Imaging
NCT01934985 ·Status: COMPLETED
-
Adenosine Dual Source Computed Tomography (CT) Versus Adenosine Single Photon Emission Computed Tomography (SPECT)
NCT00892307 ·Status: COMPLETED
-
Dobutamine vs Adenosine CMR Study
NCT03661827 ·Status: COMPLETED ·Phase: NA
-
Adenosine-induced Stress Dynamic Myocardial Perfusion Imaging With Dual-source CT
NCT01680081 ·Status: TERMINATED ·Phase: PHASE4
-
Detecting Cardiac Thrombi in Acute Ischemic Stroke on Cardiac CT Versus Transoesophageal Echocardiography
NCT06585228 ·Status: RECRUITING
-
Breath-hold Cardiac Hybrid SPECT/CCTA
NCT02469051 ·Status: COMPLETED ·Phase: NA
-
Mechanical Dyssynchrony and Microvascular Dysfunction by SPECT
NCT06969547 ·Status: RECRUITING
-
A Study of Regadenoson in Subjects Undergoing Stress Myocardial Perfusion Imaging (MPI) Using Multidetector Computed Tomography (MDCT) Compared to Single Photon Emission Computed Tomography (SPECT)
NCT01334918 ·Status: COMPLETED ·Phase: PHASE2