RADIQAL Study (Radiation Dose and Image Quality Trial)
NCT06944509 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 824
Last updated 2025-07-30
Summary
The Azurion R4.0 is developed by Philips Medical Systems Nederland B.V., a Philips Healthcare company. The Azurion is an interventional X-ray system which is used for live X-ray imaging during invasive cardiac procedures. The proposed Azurion R4.0 includes new x-ray image postprocessing (Xres5) compared to its predecessor, which was equipped with ClarityIQ image post-processing (Xres4).
Azurion R4.0 is a cleared device for EU-MDR regulated countries, submission for FDA510K clearance in the US is pending. Sites in the US will only be activated in the study after FDA clearance.
This is a prospective, randomized, unblinded, comparative, international, multi-center clinical investigation. Randomization will be 1:1 between Xres5 and ClarityIQ (Xres4). Stratification will be performed per site on intended procedure type (based on clinical presentation) and patient BMI.
Primary objective is to demonstrate that in coronary procedures, Xres5 can reduce overall patient radiation dose compared to the current ClarityIQ without affecting procedural performance.
It is expected that 824 subjects are necessary to collect sufficient data for the evaluation of the objectives of this clinical study. The enrollment period is expected to last for 12 months. The study will be executed in Spain, Czech republic, Denmark and the US.
Conditions
Interventions
- DEVICE
-
treatment with the Azurion system with Xres5
treatment with the Azurion system with Xres5
- OTHER
-
Azurion with Clairy IQ
Azurion system with the standard of care (ClarityIQ/Xres4)
Sponsors & Collaborators
-
Philips Clinical & Medical Affairs Global
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2025-05-14
- Primary Completion
- 2026-10-31
- Completion
- 2026-12-31
- FDA Device
- Yes
Countries
- United States
- Czechia
- Denmark
- Spain
Study Locations
More Related Trials
-
Gadofosveset Trisodium for Heart Imaging Studies
NCT01853592 ·Status: COMPLETED
-
Cardiac Effects From Radiation Therapy by MRI
NCT04486573 ·Status: COMPLETED ·Phase: NA
-
Artifact-Free High-Resolution Myocardial Perfusion MRI in Subjects With Abnormal Nuclear Myocardial Perfusion Studies
NCT01949844 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Study of Rapid Regadenoson Stress Cardiovascular Magnetic Resonance (CMR) to Detect Coronary Artery Disease
NCT01446094 ·Status: UNKNOWN ·Phase: PHASE4
-
Technical Development of Cardiovascular Magnetic Resonance Imaging (CMR) Using a Low Specific Absorption Rate (SAR) Scanner System
NCT03331380 ·Status: RECRUITING ·Phase: NA
-
Imaging of Vulnerable Plaques in Coronary Artery Disease by Multidetector Computed Tomography
NCT00482651 ·Status: COMPLETED ·Phase: NA
-
iNav-based, Automated Coronary Magnetic Resonance Angiography for the Detection of Coronary Artery Stenosis
NCT05473117 ·Status: NOT_YET_RECRUITING
-
Whole-Heart Myocardial Blood Flow Quantification Using MRI
NCT03064295 ·Status: UNKNOWN
-
Prospective Randomized Trial On Radiation Dose Estimates Of CT Angiography In Patients Applying Iterative Image Reconstruction Techniques - The PROTECTION V Study -
NCT01453712 ·Status: UNKNOWN ·Phase: PHASE4
-
Implementation of Non-size Markers Derived From 4D Flow MRI of Patients With Aortic Disease.
NCT02467062 ·Status: COMPLETED ·Phase: NA
-
CardioPET as PET Imaging Agent to Assess Myocardial Perfusion and Fatty Acid Uptake in Known or Suspected CAD Subjects
NCT01826773 ·Status: COMPLETED ·Phase: PHASE2
-
A Study of Gadodiamide Injection in Myocardial Perfusion Magnetic Resonance Imaging
NCT00977093 ·Status: COMPLETED ·Phase: PHASE3
-
Patient Registry Of Magnetic Resonance Imaging in Non-Approved DEvices
NCT03081364 ·Status: COMPLETED
-
Advanced Cardiac Magnetic Resonance Imaging for Assessment of Obstructive Coronary Artery Disease: ADVOCATE-CMR
NCT06419894 ·Status: NOT_YET_RECRUITING
-
Ammonia N-13 Myocardial Blood Flow Absolute Quantification by PET in Patients With Known or Suspected CAD (Ammonia MAP)
NCT04343209 ·Status: COMPLETED
-
Safety and Effectiveness of Coronary Magnetic Resonance Angiography (CMRA) Imaging
NCT00001633 ·Status: COMPLETED ·Phase: PHASE2
-
Phase Analysis and Obstructive CAD on Rubidium PET
NCT01840696 ·Status: WITHDRAWN ·Phase: PHASE2
-
Natural History of Carotid Plaque as Determined by 3D Ultrasound
NCT03314818 ·Status: UNKNOWN
-
Evaluation of the CAD-det System, a Novel Non-Invasive Acoustic Diagnostic for the Diagnosis of Coronary Artery Disease
NCT03914079 ·Status: SUSPENDED
-
Reduced Radiation Dose and IR-impact on Coronary Calcium Quantification
NCT04267094 ·Status: TERMINATED ·Phase: NA
-
iFR Guided Multi-vessel Revascularization During Percutaneous Coronary Intervention for Acute Myocardial Infarction
NCT03298659 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Non-invasive and Invasive Assessment of Coronary Artery Disease
NCT01823809 ·Status: TERMINATED ·Phase: NA
-
Identifying Vulnerable Plaques in Blood Vessels of the Heart Using a New Imaging Technique
NCT00540761 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Clinical Evaluation of Radiation Reduction for Optimized Safety
NCT06348875 ·Status: NOT_YET_RECRUITING
-
Gadobutrol/Gadavist-enhanced Cardiac Magnetic Resonance Imaging (CMRI) to Detect Coronary Artery Disease (CAD)
NCT01890421 ·Status: COMPLETED ·Phase: PHASE3