Diagnostic Accuracy Study of Indocyanine Green for Perfusion Assessment
NCT06579430 · Status: COMPLETED · Phase: EARLY_PHASE1 · Type: INTERVENTIONAL · Enrollment: 80
Last updated 2024-09-19
Summary
Background Near-infrared fluorescence guided surgery with indocyanine green (ICG) was introduced for parathyroid perfusion assessment during total thyroidectomy in 2016. ICG can visualize tissue perfusion, since it becomes completely and permanently fixed to plasma proteins in the bloodstream, and circulates in the intravascular compartment only. ICG was already approved in 1956 for clinical use of tissue perfusion. However, until now there is still no (parathyroid) universal standard imaging protocol for ICG-guided fluorescent surgery including quantitative evaluation.
Main research question To develop a standardized universal imaging protocol for the assessment of parathyroid perfusion during total thyroidectomy with ICG including quantitative evaluation of the fluorescent signal.
• Design (including population, confounders/outcomes) This will be a proof-of-concept, prospective cohort study of patients undergoing an ICG-guided fluorescent total thyroidectomy to evaluate parathyroid gland perfusion. The main study endpoint is quantification of the fluorescent signal of ICG stratified by the occurrence of hypoparathyroidism. Hypoparathyroidism will be defined as a decrease in PTH of \>70% at the first postoperative day. Furthermore, we will calculate the sensitivity of our model for the prediction of hypoparathyroidism.
Secondary outcomes are data from surgery, pre- and postoperative lab values (including calcium, PTH, albumin) and postoperative medication use.
Expected results We expect that the results of this study will lead to the development of a universal standard imaging protocol for ICG-guided fluorescent total thyroidectomy.
Conditions
- Hypoparathyroidism
Interventions
- DRUG
-
Indocyanine Green near infrared fluorescence imaging
ICG-NIRF was performed using the Quest Spectrum Platform 2.0. The camera lens was positioned at a fixed distance of 30 cm to the wound bed, at a perpendicular angle, with the gain set at 22.5 decibels (dB) and an exposure time of 50 milliseconds (ms). ICG was dissolved in sterile water at a concentration of 2.5 mg/mL as recommended by the manufacturer (Verdye). 1.5 mg of ICG per liter of circulating blood volume was then administered through manual bolus intravenous injection. Blood volume estimation was based on the patient\'s height and weight.
- DRUG
-
Indocyanine Green near infrared fluorescence imaging
ICG-NIRF was performed using the Quest Spectrum Platform 2.0. The camera lens was positioned at a fixed distance of 30 cm to the wound bed, at a perpendicular angle, with the gain set at 22.5 decibels (dB) and an exposure time of 50 milliseconds (ms). ICG was dissolved in sterile water at a concentration of 0.5 or 2.5 mg/mL as recommended by the manufacturer. 1.5 mg of ICG per liter of circulating blood volume was then administered through manual bolus intravenous injection. Blood volume estimation was based on the patients height and weight. Different administration rates (fast: 2s, slow: 15-20s) and a different camera system were tested. Group 1: Quest Platform 2.0; Fast/Slow; 2.5 mg/mL Group 2: Quest Platform 2.0; Slow/Fast; 2.5 mg/mL Group 3: Quest Platform 2.0; Fast/Fast; 2.5 mg/mL Group 4: Stryker Spy-Elite; Fast/Fast; 2.5 mg/mL Group 5: Quest Platform 2.0; Fast/Fast; 0.5 mg/mL
Sponsors & Collaborators
- collaborator OTHER
-
Leiden University Medical Center
collaborator OTHER -
University Medical Center Groningen
lead OTHER
Principal Investigators
-
Schelto Kruijff, Professor · UMCG
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-11-05
- Primary Completion
- 2024-05-02
- Completion
- 2024-05-02
Countries
- Netherlands
Study Locations
More Related Trials
-
Determination of Parathyroid Function by Fluorescence With Indocyanine Green (ICG) After Total Thyroidectomy
NCT04012476 ·Status: UNKNOWN ·Phase: PHASE4
-
Protective Effect of Indocyanine Green Fluorescence Imaging Technology on Parathyroid Glands During Total Thyroidectomy
NCT06288750 ·Status: RECRUITING ·Phase: NA
-
Parathyroid Vascularization During Total Thyroidectomy Using Indocyanine Green Angiography
NCT05328076 ·Status: TERMINATED
-
Does Fluorescence With or Without Indocyanine Green Improve Parathyroid Identification and Preservation
NCT06169735 ·Status: TERMINATED ·Phase: PHASE4
-
NIRF for Parathyroid Visualization: a Pilot Study
NCT03012438 ·Status: COMPLETED ·Phase: NA
-
Near-infrared Imaging Techniques for Identifying and Preserving Viable Parathyroid Glands During Thyroidectomy
NCT05130476 ·Status: COMPLETED ·Phase: NA
-
Does Indocyanine Imaging Scoring Predicts Postoperative Parathormone Levels at 24 Hours After Total Thyroidectomy
NCT03910049 ·Status: COMPLETED
-
Near-infrared Fluorescence With Indocyanine Green for Identification of Sentinels and Parathyroids During Thyroidectomy
NCT04424485 ·Status: UNKNOWN ·Phase: NA
-
Near Infrared (NIR) Autofluorescence Image-guided Thyroid Surgery
NCT04193332 ·Status: UNKNOWN ·Phase: NA
-
Autofluorescence and Indocyanine Green to Avoid Hypocalcemia After Thyroidectomy
NCT05117853 ·Status: RECRUITING ·Phase: PHASE3
-
Intra-operative Infra-red Fluorescent Imaging in Thyroid and Parathyroid Surgery
NCT02089542 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Parathyroid Autofluorescence Visualization in Thyroid Surgery: Impact on Postoperative Hypocalcemia
NCT02892253 ·Status: COMPLETED ·Phase: NA
-
Intraoperative Parathyroid Gland (PTG) Identification Using a Hand-Held Imager (HHI)
NCT06939946 ·Status: TERMINATED ·Phase: PHASE1
-
Resting Heart Rate Monitoring for Optimized Treatment and Surveillance of Hyperthyroidism
NCT04932135 ·Status: COMPLETED
-
Assessment of Thyroid Doppler Ultrasound in Followup of Pediatric Graves' Disease
NCT06357494 ·Status: NOT_YET_RECRUITING
-
Assessing Benefits of NIRAF Detection for Identifying Parathyroid Glands During Total Thyroidectomy.
NCT04281875 ·Status: COMPLETED ·Phase: NA
-
Near-infrared Autofluorescence (NIRAF)-Guided Total Thyroidectomy: Impact in Low-volume, Non-parathyroid Institutions
NCT05043584 ·Status: COMPLETED ·Phase: NA
-
Assessing Benefits of Near Infrared Autofluorescence (NIRAF) Detection for Identifying Parathyroid Glands During Total Thyroidectomy
NCT05022667 ·Status: COMPLETED ·Phase: NA
-
Postoperative Dose of Parathyroid Hormone as a Marker for the Occurrence of Hypoparathyroidism After Total Thyroidectomy
NCT02924532 ·Status: COMPLETED
-
Clinical Impact of Parathyroid Autofluorescence Visualization During Thyroid Surgery
NCT02889952 ·Status: COMPLETED
-
Assessing Benefits of NIRAF Detection for Identifying Parathyroid Glands During Total Thyroidectomy
NCT05579782 ·Status: COMPLETED ·Phase: NA
-
Heart Rate Monitoring by Wearable Devices in Graves' Disease
NCT04333342 ·Status: UNKNOWN ·Phase: NA
-
Study of Usefulness of Fluorescence in Thiroid Surgery
NCT06011369 ·Status: UNKNOWN ·Phase: NA
-
Intra-operative Rapid Identification of Lymph Node and Parathyroid
NCT03268785 ·Status: UNKNOWN ·Phase: NA
-
Thyroid Cancer and Central Lymph Node Metastases Detection Using Bevacizumab-IRDye800CW
NCT06095362 ·Status: COMPLETED ·Phase: PHASE1