Assessing Benefits of Near Infrared Autofluorescence (NIRAF) Detection for Identifying Parathyroid Glands During Total Thyroidectomy
NCT05022667 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 114
Last updated 2025-08-08
Summary
This study will see if the use of near infrared autofluorescence (NIRAF) detection with a 'Parathyroid Eye (PTeye)' for identifying parathyroid glands (PGs) during total thyroidectomy (TTx) is better than surgeon's detection alone. It compares risk, benefits and outcomes in TTx patients where NIRAF detection with PTeye for parathyroid identification is either used or not used.
Conditions
- Thyroid Neoplasms
- Thyroid Diseases
- Hypoparathyroidism
- Endocrine System Diseases
- Endocrine Gland Neoplasms
- Neoplasms by Site
- Neoplasms
- Head and Neck Neoplasms
- Parathyroid Diseases
Interventions
- DEVICE
-
PTeye
The surgeon will first take 5 baseline NIRAF measurements on the thyroid gland (or neck muscle, if thyroid is absent) using the disposable sterile fiber probe that is connected to the PTeye console, as per device functionality requirements.
Sponsors & Collaborators
-
Vanderbilt University
collaborator OTHER - lead OTHER
Principal Investigators
-
Paul Gauger, MD · University of Michigan
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-12-01
- Primary Completion
- 2024-05-31
- Completion
- 2024-05-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
NIRF for Parathyroid Visualization: a Pilot Study
NCT03012438 ·Status: COMPLETED ·Phase: NA
-
Clinical Impact of Parathyroid Autofluorescence Visualization During Thyroid Surgery
NCT02889952 ·Status: COMPLETED
-
Near-infrared Imaging Techniques for Identifying and Preserving Viable Parathyroid Glands During Thyroidectomy
NCT05130476 ·Status: COMPLETED ·Phase: NA
-
Near-infrared Autofluorescence (NIRAF)-Guided Total Thyroidectomy: Impact in Low-volume, Non-parathyroid Institutions
NCT05043584 ·Status: COMPLETED ·Phase: NA
-
Intra-operative Infra-red Fluorescent Imaging in Thyroid and Parathyroid Surgery
NCT02089542 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
Near Infrared Fluorescent Imaging in Thyroid and Parathyroid Surgery With the Fluobeam(TM) System of Fluoptics
NCT01598727 ·Status: COMPLETED ·Phase: PHASE1
-
Near Infrared (NIR) Autofluorescence Image-guided Thyroid Surgery
NCT04193332 ·Status: UNKNOWN ·Phase: NA
-
Parathyroid Autofluorescence Visualization in Thyroid Surgery: Impact on Postoperative Hypocalcemia
NCT02892253 ·Status: COMPLETED ·Phase: NA
-
Intraoperative Parathyroid Gland (PTG) Identification Using a Hand-Held Imager (HHI)
NCT06939946 ·Status: TERMINATED ·Phase: PHASE1
-
Protective Effect of Indocyanine Green Fluorescence Imaging Technology on Parathyroid Glands During Total Thyroidectomy
NCT06288750 ·Status: RECRUITING ·Phase: NA
-
Near-infrared Fluorescence With Indocyanine Green for Identification of Sentinels and Parathyroids During Thyroidectomy
NCT04424485 ·Status: UNKNOWN ·Phase: NA
-
Assessing Parathyroid Glands Vascularisation by ICG Fluoroscopy
NCT02249780 ·Status: COMPLETED ·Phase: NA
-
Quantitative Intra-operative Assessment of Parathyroid Perfusion Using Indocyanine Green (ICG) Fluorescence Imaging
NCT07010341 ·Status: RECRUITING
-
PTeye in Parathyroid Adenoma
NCT06913296 ·Status: RECRUITING
-
Preoperational Fine Needle Aspiration of Pathological Parathyroid Gland
NCT03516747 ·Status: WITHDRAWN ·Phase: NA
-
Does Fluorescence With or Without Indocyanine Green Improve Parathyroid Identification and Preservation
NCT06169735 ·Status: TERMINATED ·Phase: PHASE4
-
The Effect of the Application of Head Mounted Magnifying Glasses on Postoperative PTH Changes in Thyroid Surgery: Stage II
NCT06838728 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Effect of the Application of Head Mounted Magnifying Glasses on Postoperative PTH Changes in Thyroid Surgery
NCT06432257 ·Status: COMPLETED
-
Surgery for Thyroid Cancer With or Without Autofluorescence to Prevent Hypoparathyroidism
NCT06222606 ·Status: RECRUITING ·Phase: NA
-
Use of an In Vivo Optical Probe to Discriminate Benign From Malignant Thyroid Nodules
NCT01401855 ·Status: COMPLETED
-
The Novel Approach of Minimally Invasive Parathyroid Surgery Requires Precise Identification and Localization of the Lesion Prior to Exploration
NCT01226810 ·Status: UNKNOWN
-
Use of the PTEye Device to Reduce Inadvertent Parathyroidectomy During Thyroid Surgery
NCT06927245 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Autofluorescence in Surgery for Primary Hyperparathyroidism
NCT06230380 ·Status: RECRUITING ·Phase: NA
-
Autofluorescence vs Clinical Assessment of Parathyroid Glands During Thyroid Surgery
NCT04509011 ·Status: COMPLETED ·Phase: NA
-
Diagnostic Accuracy Study of Indocyanine Green for Parathyroid Perfusion Assessment
NCT03969108 ·Status: COMPLETED ·Phase: PHASE4