Efficiency and Safety of the Prolonged Use of Heat and Moisture Exchangers in ICU
NCT06410664 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 120
Last updated 2024-07-26
Summary
FILTRex is a single-centre, controlled, randomised, prospective, non-inferiority clinical trial to compare the efficiency and safety of prolonged (72-hours) versus standard (24-hours) duration of use for Heat and Moisture Exchange (HME) filters in adult mechanically ventilated critically ill patients
Conditions
- VAP - Ventilator Associated Pneumonia
Interventions
- OTHER
-
72-hour HME exchange interval group
All patients in the experimental arm will receive the usual best medical and nursing care with respect to VAP prevention. A dual-limb ventilator circuit with a closed suction system will be used. Bronchodilation or inhalational antibiotics, when ordered, will be delivered by a meshed nebuliser, a part of the ventilatory support circuit and will not be removed between treatments. A closed-circuit suction device will be used, and the frequency of suctioning will be monitored, including the sputum consistency and blood on suctioning. HME filter resistance by estimating the pressure drop over HME using the ventilatory circuit's auxiliary force (Paux) and flow. Temperature and humidity in the ventilator circuit will be measured. HME filters will be exchanged every 72 hours. At the exchange point, both outlets of the HME filter will be swabbed.
- OTHER
-
24-hour HME exchange interval group
All patients in the control arm will receive the usual best medical and nursing care with respect to VAP prevention. A dual-limb ventilator circuit with a closed suction system will be used. Bronchodilation or inhalational antibiotics, when ordered, will be delivered by a meshed nebuliser, a part of the ventilatory support circuit and will not be removed between treatments. A closed-circuit suction device will be used, and the frequency of suctioning will be monitored, including the sputum consistency and blood on suctioning. HME filter resistance by estimating the pressure drop over HME using the ventilatory circuit's auxiliary force (Paux) and flow. Temperature and humidity in the ventilator circuit will be measured. HME filters will be exchanged every 24 hours. At the exchange point, both outlets of the HME filter will be swabbed.
Sponsors & Collaborators
-
Charles University, Czech Republic
lead OTHER
Principal Investigators
-
Kateřina Jiroutková · 3rd Faculty of Medicine, Charles University and FNKV, Prague
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-05-01
- Primary Completion
- 2025-08-31
- Completion
- 2026-06-30
Countries
- Czechia
Study Locations
More Related Trials
-
Wise Choices in the Intensive Care Unit
NCT07013175 ·Status: RECRUITING ·Phase: NA
-
Generating Evidence in ECMO Ventilation Strategies
NCT05708365 ·Status: COMPLETED ·Phase: NA
-
The Effect of NOn-invasive Respiratory Support on outcoMe and Its Risks in SARS-COV-2-related Hypoxemic Respiratory Failure
NCT06757166 ·Status: RECRUITING
-
Hemodynamic Responses to Ventilator Hyperinflation Technique
NCT02739841 ·Status: COMPLETED ·Phase: NA
-
The Oscillation for Acute Respiratory Distress Syndrome (ARDS) Treated Early (OSCILLATE) Trial
NCT01506401 ·Status: TERMINATED ·Phase: PHASE3
-
Mode of Ventilation During Critical Illness at Multiple Centers
NCT07313956 ·Status: ENROLLING_BY_INVITATION ·Phase: NA
-
Evaluating the Short-term Efficacy of Two Oscillation Techniques in Hypersecretive Mechanically Ventilated Patients
NCT06675942 ·Status: RECRUITING ·Phase: NA
-
Effects of Airway Conditioning Devices on Ventilator Associated Pneumonia:a Randomized Clinical Trial
NCT01150864 ·Status: COMPLETED ·Phase: NA
-
The Effect of High Frequency Oscillation on Biological Markers of Lung Injury
NCT00673517 ·Status: COMPLETED
-
Low Frequency, Ultra-low Tidal Volume Ventilation in Patients With ARDS and ECMO
NCT03764319 ·Status: COMPLETED ·Phase: NA
-
ARDSnet Protocol vs. Open Lung Approach in ARDS
NCT00431158 ·Status: COMPLETED ·Phase: NA
-
Epidemiology and Outcome of Ventilator-associated Pneumonia Among Critically Ill COVID-19 Patients
NCT04372576 ·Status: UNKNOWN
-
CT for Personalized Mechanical Ventilation
NCT05977153 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Mechanical Ventilation in Patients With Lung Impairment Controlled by the Mechanical Energy of the Respiratory System
NCT06035146 ·Status: RECRUITING ·Phase: NA
-
Biphasic Positive Airway Pressure Ventilation Versus Flow-Controlled Ventilation in Burn Patients
NCT07041957 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Leg Exercise During ECMO
NCT03135210 ·Status: COMPLETED ·Phase: NA
-
Comparing Closed-loop FiO2 Controller With Conventional Control of FiO2
NCT04568642 ·Status: COMPLETED ·Phase: NA
-
Blend to Limit Oxygen in ECMO: A Randomised Controlled Registry Trial
NCT03841084 ·Status: COMPLETED ·Phase: PHASE2
-
Comparative Study of Non-Invasive Mask Ventilation vs Cuirass Ventilation in Patients With Acute Respiratory Failure.
NCT00331656 ·Status: UNKNOWN ·Phase: PHASE4
-
The Efficacy of Nurse-driven, Protocol Guided Ventilator Weaning in a Medical-Surgical Intensive Care Unit (ICU)
NCT00786617 ·Status: COMPLETED
-
RCT of Mesh Versus Jet Nebulizers on Clinical Outcomes During Mechanical Ventilation in the Intensive Care Unit
NCT02056119 ·Status: COMPLETED ·Phase: NA
-
HEaling LIght Algorithms for the ICU Patient
NCT05556811 ·Status: COMPLETED ·Phase: NA
-
Flow-controlled Ventilation (FCV) in Moderate Acute Respiratory Distress Syndrome (ARDS) Due to COVID-19
NCT04894214 ·Status: COMPLETED
-
Electrical Impedance Tomography-Derived Dorsal Recruitment-to-Inflation Ratio Identifies PEEP Responsiveness and Risk Phenotypes in ARDS
NCT06823804 ·Status: COMPLETED
-
Early Switch from Controlled to Assisted Ventilation
NCT06438198 ·Status: RECRUITING ·Phase: NA