Efficiency and Safety of the Prolonged Use of Heat and Moisture Exchangers in ICU

NCT06410664 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 120

Last updated 2024-07-26

No results posted yet for this study

Summary

FILTRex is a single-centre, controlled, randomised, prospective, non-inferiority clinical trial to compare the efficiency and safety of prolonged (72-hours) versus standard (24-hours) duration of use for Heat and Moisture Exchange (HME) filters in adult mechanically ventilated critically ill patients

Conditions

  • VAP - Ventilator Associated Pneumonia

Interventions

OTHER

72-hour HME exchange interval group

All patients in the experimental arm will receive the usual best medical and nursing care with respect to VAP prevention. A dual-limb ventilator circuit with a closed suction system will be used. Bronchodilation or inhalational antibiotics, when ordered, will be delivered by a meshed nebuliser, a part of the ventilatory support circuit and will not be removed between treatments. A closed-circuit suction device will be used, and the frequency of suctioning will be monitored, including the sputum consistency and blood on suctioning. HME filter resistance by estimating the pressure drop over HME using the ventilatory circuit's auxiliary force (Paux) and flow. Temperature and humidity in the ventilator circuit will be measured. HME filters will be exchanged every 72 hours. At the exchange point, both outlets of the HME filter will be swabbed.

OTHER

24-hour HME exchange interval group

All patients in the control arm will receive the usual best medical and nursing care with respect to VAP prevention. A dual-limb ventilator circuit with a closed suction system will be used. Bronchodilation or inhalational antibiotics, when ordered, will be delivered by a meshed nebuliser, a part of the ventilatory support circuit and will not be removed between treatments. A closed-circuit suction device will be used, and the frequency of suctioning will be monitored, including the sputum consistency and blood on suctioning. HME filter resistance by estimating the pressure drop over HME using the ventilatory circuit's auxiliary force (Paux) and flow. Temperature and humidity in the ventilator circuit will be measured. HME filters will be exchanged every 24 hours. At the exchange point, both outlets of the HME filter will be swabbed.

Sponsors & Collaborators

  • Charles University, Czech Republic

    lead OTHER

Principal Investigators

  • Kateřina Jiroutková · 3rd Faculty of Medicine, Charles University and FNKV, Prague

Study Design

Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
DOUBLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2024-05-01
Primary Completion
2025-08-31
Completion
2026-06-30

Countries

  • Czechia

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT06410664 on ClinicalTrials.gov