RCT of Mesh Versus Jet Nebulizers on Clinical Outcomes During Mechanical Ventilation in the Intensive Care Unit
NCT02056119 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 120
Last updated 2023-03-21
Summary
Aerosol delivery during mechanical ventilation has long been a long debated topic. As evidence-based knowledge about the delivery of aerosol to the lungs of mechanically ventilated patients increases, one piece of the puzzle has remained unexplored; measurement of clinically relevant outcomes. The primary aim of this research is to compare clinical outcomes (ventilator-associated events (VAEs), length of stay (LOS) in intensive care unit (ICU), and total days on mechanical ventilation) when using a traditional jet nebulizer versus a newer generation vibrating mesh nebulizer during mechanical ventilation. The secondary aim of this research is to identify source of bacteria by obtaining cultures of each nebulizer and ventilator circuit and plating them for colony growth and identification.
Conditions
- Respiratory Insufficiency
Interventions
- DEVICE
-
Vibrating Mesh Nebulizer Arm
* Physician order received for subject, randomization to vibrating mesh nebulizer occurred. * Aeroneb® Solo (Aerogen, Galway, Ireland) vibrating mesh nebulizer to be placed before the heater on the "dry side" of the heater water chamber on the inspiratory ventilator circuit. * Aerosol treatment delivered per physician order. * Mesh nebulizer to be replaced every 30 days per hospital protocol. a. Prior to every nebulizer change or every 3 days, study staff to be notified in order to obtain cultures.
- DEVICE
-
Jet Nebulizer Arm
* Physician order received for subject, randomization to jet nebulizer occurred. * Jet nebulizer, Misty Max 10™ (Carefusion, CA), placed into spring loaded t-piece between the humidifier and the ventilator (approximately 15 cm from the gas outlet). * Aerosol treatment delivered per physician order at flow rates of 8-10 L/min. * Jet nebulizer to be replaced every 3 days per hospital protocol. a. Prior to every nebulizer change or every 3 days, study staff to be notified in order to obtain cultures.
Sponsors & Collaborators
-
Rush University Medical Center
lead OTHER
Principal Investigators
-
Meagan N Dubosky, MS · Rush University, Respiratory Care Research Coordinator
Study Design
- Allocation
- RANDOMIZED
- Purpose
- BASIC_SCIENCE
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 1 Year
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2013-09-30
- Primary Completion
- 2014-10-31
- Completion
- 2014-10-31
Countries
- United States
Study Locations
More Related Trials
-
Evaluating the Short-term Efficacy of Two Oscillation Techniques in Hypersecretive Mechanically Ventilated Patients
NCT06675942 ·Status: RECRUITING ·Phase: NA
-
PReventing EXtubation FAILure Related to Cough
NCT03562000 ·Status: TERMINATED ·Phase: NA
-
Mechanical Power-Guided Lung Protective Ventilation (VentCoach) in Acute Hypoxemic and/or Hypercapnic Respiratory Failure
NCT07294768 ·Status: COMPLETED ·Phase: NA
-
Comparative Study of Non-Invasive Mask Ventilation vs Cuirass Ventilation in Patients With Acute Respiratory Failure.
NCT00331656 ·Status: UNKNOWN ·Phase: PHASE4
-
Intubation and Extubation Over 48 Hours Mechanical Ventilation
NCT01123681 ·Status: UNKNOWN
-
Noninvasive Ventilation Masks Carbon Dioxide Clearance in Normal Volunteers
NCT03882723 ·Status: COMPLETED ·Phase: NA
-
Mechanical Insufflation-exsufflation and Hypertonic Saline in Nosocomial Bacterial Respiratory Tract Infection
NCT06310941 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
NIV With Airway Washout for Dual Limb Ventilation: Improvement in Minute Ventilation
NCT06939920 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Early Directed Physical Therapy in the Management of Mechanically Ventilated Patients in a Medical Intensive Care Unit
NCT00322010 ·Status: COMPLETED ·Phase: PHASE2
-
The Effect of NOn-invasive Respiratory Support on outcoMe and Its Risks in SARS-COV-2-related Hypoxemic Respiratory Failure
NCT06757166 ·Status: RECRUITING
-
Effectiveness of Routine Nebulization of Mucolytics and Bronchodilators During Mechanical Ventilation
NCT02159196 ·Status: COMPLETED ·Phase: NA
-
Respiratory Supports and COVID-19 Mortality
NCT04832061 ·Status: COMPLETED
-
The Effects of Different Flow Settings on Lung Impedance
NCT06228703 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Mechanical Ventilation as a Rescue Therapy to Relieve Dyspnea in Patients With Stable Severe COPD
NCT02012101 ·Status: COMPLETED ·Phase: NA
-
AMBU Bag Manual Ventilation vs. Transport Ventilator Mechanical Ventilation for Transport
NCT06006208 ·Status: COMPLETED ·Phase: NA
-
Evaluating the Patient-Ventilator Synchrony During Mechanical Ventilation in Patients With Acute Lung Injury
NCT01541514 ·Status: COMPLETED
-
Bag Valve Mask vs Non-rebreather at Flush Rate
NCT02798302 ·Status: COMPLETED ·Phase: NA
-
Different Modalities in Reducing Airborne Particulate Concentrations During AGP for Health Volunteers
NCT04681599 ·Status: COMPLETED ·Phase: NA
-
The Impact Of Respiratory Neuromuscular Stimulation On Patients With Invasive Mechanical Ventilation
NCT06952335 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Nasal Airflow to Modulate Dyspnea in Tracheostomized Patients
NCT07308171 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Non-Invasive Ventilation Via a Helmet Device for Patients Respiratory Failure
NCT01680783 ·Status: COMPLETED ·Phase: NA
-
Pilot Physiological Evaluation of an Investigational Mask with Expiratory Washout.
NCT06007495 ·Status: RECRUITING ·Phase: NA
-
CYCLE Pilot Randomized Trial
NCT02377830 ·Status: COMPLETED ·Phase: PHASE2
-
Comparison of Physiological Effects of Two High-Flow Tracheal Oxygen Versus T-Piece During Spontaneous Breathing Trials
NCT06816706 ·Status: RECRUITING ·Phase: NA
-
Comparison of Synchrony Between 4 NIV Ventilators
NCT01615432 ·Status: COMPLETED ·Phase: NA