Patient Satisfaction and Maximum Biting Force in Co-Cr Bar Implant Overdenture
NCT06401187 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 30
Last updated 2024-05-16
Summary
Statement of problem. Patient satisfaction and maximum biting force from patients who wear 2-implant-retained overdentures with different constructed bar attachments can be improved.
Purpose. This randomised controlled clinical trial assessed patient satisfaction and maximum biting force with three differently constructed bar-retained overdentures (conventional casting, Milling and 3D printing CAD/CAM techniques) within a one-year follow-up.
Material and methods. A total of 60 implants were placed in 30 mandibular jaws(30 participants). The jaws were randomly assigned to 1 of the 3 treatment groups: a 10 conventional technique cast Co-Cr bar attachment, a 10 Co-Cr CAD/CAM milled bar attachment, and a 10 Co-Cr CAD/CAM 3D-printed bar attachment all groups were connected to 2 implants in the canine area. Patient satisfaction was tested after 6 months, and 12 months for each group; the results were collected, tabulated, and statistically analysed using a Pair-wise comparisons test and the Kruskal-Wallis test. Maximum biting force was tested at baseline,3 months, 6 months, and 12 months for each group; the results were collected, tabulated, and statistically analysed using a Pair-wise comparisons test and ANOVA test.
Conditions
- Dental
Interventions
- OTHER
-
Bar overdenture
use of bar attachments as retentive mean of denture
Sponsors & Collaborators
-
Minia University
lead OTHER
Principal Investigators
-
Amr E Badr, phd · professor
Study Design
- Allocation
- RANDOMIZED
- Purpose
- HEALTH_SERVICES_RESEARCH
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 50 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-11-10
- Primary Completion
- 2023-12-15
- Completion
- 2024-01-17
Countries
- Egypt
Study Locations
More Related Trials
-
Immediate Loading of Four Single Piece Compressive Implants for Bar Retained Mandibular Overdenture
NCT06514391 ·Status: COMPLETED ·Phase: NA
-
Mandibular Implant Overdenture With OT Cap Bar vs Bar Attachment
NCT07067190 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
3D-Printed Implant Overdentures: Comparing Impression Techniques
NCT07208812 ·Status: RECRUITING ·Phase: NA
-
Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
NCT07250503 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Patient Satisfaction and Prosthetic Complications of Bar Locator Versus Bar Clip Attachments for Mandibular Two-Implant Overdentures
NCT06673186 ·Status: COMPLETED ·Phase: NA
-
Patient's Satisfaction of Mandibular Implant Supported Overdentures With Reduced Denture Base Extensions.
NCT06850558 ·Status: COMPLETED ·Phase: NA
-
A Seven-year Follow-up Study of Patient Satisfaction With Three-Implant-Retained Mandibular Overdentures
NCT04726540 ·Status: COMPLETED
-
Crestal Bone Loss in Mandibular Telescopic Overdentures. Overdenture with Milled Titanium, Milled Poly-ether Ketone Ketones and 3D Printed Chrome Cobalt Secondary Copings.
NCT06639893 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Patient Satisfaction and Oral Health-Related Quality of Life of Quadrilateral Versus Bilateral Linear Bar Designs for Four Implant Implant-Assisted Complete Mandibular Overdenture Regarding Peri-Implant Crestal Bone Loss
NCT06673173 ·Status: COMPLETED ·Phase: NA
-
Mandibular Overdentures Retained by Mini Implants: a Clinical Trial Comparing Different Surgical and Loading Protocols
NCT04760457 ·Status: COMPLETED ·Phase: NA
-
Four Implant Retained Mandibular Overdenture VERSUS Fixed-detachable Prosthesis.
NCT07144787 ·Status: COMPLETED ·Phase: NA
-
The Effect of Clip Material on the Retention of Implant Supported Mandibular Overdenture
NCT06866067 ·Status: COMPLETED ·Phase: NA
-
Mandibular Overdentures Retained by Conventional or Mini Implants
NCT01411683 ·Status: COMPLETED ·Phase: NA
-
Zirconia Bars for Mandibular Implant Overdentures
NCT06471881 ·Status: COMPLETED ·Phase: NA
-
Implant Retained Overdenture VERSUS Implant Canine Retained Overdenture.
NCT07046104 ·Status: COMPLETED ·Phase: NA
-
SFI Bars and Milled Bars Supporting Mandibular Overdentures. Three-year Randomized Clinical Trial
NCT06620497 ·Status: COMPLETED ·Phase: NA
-
Prosthetic Maintenance of Two Implant-Retained Overdentures Reinforced With PEKK Versus Co-Cr Frameworks
NCT06219811 ·Status: COMPLETED ·Phase: NA
-
Porcelain-fused-to-metal Versus Zirconia Implant- Supported in Mandibular Kennedy Class II
NCT06150768 ·Status: RECRUITING ·Phase: NA
-
Occlusion and Disocclusion Time in Immediately Loaded Overdentures Supported by Two Splinted Versus Non Splinted Interforaminal Implants
NCT06376019 ·Status: COMPLETED ·Phase: NA
-
Patient Satisfaction With Different Numbers of Implants
NCT05882617 ·Status: COMPLETED ·Phase: NA
-
Assessment of Bone Volume Changes in Immediate Implant Placement Using Allograft Versus Xenograft in Mandibular Molars
NCT06962878 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Patient Satisfaction and Retention in Implant Supported Telescopic Overdenture With Different Copings
NCT04032223 ·Status: UNKNOWN ·Phase: NA
-
Impact of Mandibular Overdenture Base Construction Techniques on Assessment of Occlusion
NCT06080815 ·Status: COMPLETED ·Phase: NA
-
Ultrasound Investigation of Tongue Movement for Implant Overdenture
NCT06705114 ·Status: COMPLETED ·Phase: NA
-
Clinical Investigation of Mandibular Implant Overdenture
NCT00066014 ·Status: COMPLETED ·Phase: PHASE2