Xeltis Hemodialysis Access (aXess) Conduit: aXess-E Study
NCT06329310 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 20
Last updated 2025-04-04
Summary
A prospective, single arm, non-randomized feasibility study to confirm the safety and performance of the Xeltis Hemodialysis Access conduit, aXess-E, in subjects older than 18 years with end-stage renal disease, who plan to undergo hemodialysis for at least the first 6 months after study access creation.
Conditions
Interventions
- DEVICE
-
aXess-E conduit
The aXess-E conduit is a sterile, regenerative biodegradable polymer-based vascular conduit, consisting of a tubular structure with a 6mm inner diameter. It is comprised of a highly porous polymer matrix and an embedded electropolished nitinol reinforcement layer (Strain Relief System). The aXess-E conduit is able to support both straight and loop configurations and may be implanted in the upper arm and forearm.
Sponsors & Collaborators
-
Xeltis
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-12-16
- Primary Completion
- 2025-12-31
- Completion
- 2026-12-31
Countries
- Portugal
- Serbia
Study Locations
More Related Trials
-
Effects of pHA Hemoperfusion Plus Hemodialysis on Protein-Bound Uremic Toxins
NCT07016841 ·Status: RECRUITING
-
Super High-Flux - High Volume Dialysis in Sepsis-Induced Acute Renal Failure
NCT00333593 ·Status: COMPLETED ·Phase: PHASE1/PHASE2
-
ACCESS HD: Comparing Catheters to Fistulas in Elderly Patients Starting Hemodialysis
NCT02675569 ·Status: UNKNOWN ·Phase: NA
-
Native Kidney Denervation in Patients With End Stage Renal Disease
NCT00551304 ·Status: COMPLETED ·Phase: PHASE1
-
Percutaneous Less Invasive AV Fistula for Vascular Access in ESRD
NCT02363972 ·Status: COMPLETED ·Phase: NA
-
Registry of GORE® ACUSEAL Vascular Graft in Dialysis Access
NCT05846581 ·Status: RECRUITING
-
Vienna Vascular Access Studied on Exchange of Dialysis Catheters for Shunts Where Feasible
NCT05704140 ·Status: UNKNOWN
-
Early Feasibility Study of the Velocity™ Percutaneous Arterio-Venous Fistula System for Creating Hemodialysis Vascular Access
NCT06712251 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
The Relationship Between the Flow of Arteriovenous Fistula and Cardiac Function in Haemodialysis Patients
NCT02747966 ·Status: COMPLETED
-
Evaluation of STARgraft-3 for Hemodialysis
NCT05729620 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Toxins Removal and Inflammatory State modulAtion During Online Hemodiafiltration: Comparison of Two Different Dialyzers
NCT04554498 ·Status: UNKNOWN ·Phase: NA
-
Clinical Observation of the Performance of Artis Dialysis System, ArtiSet PrePost and Ultra HDF Line in Treatments of Patients With End-Stage Renal Disease (ESRD)
NCT03859830 ·Status: COMPLETED ·Phase: NA
-
A Clinical Trial of IntensiVE Dialysis
NCT00649298 ·Status: COMPLETED ·Phase: PHASE4
-
Safety and Efficacy Assessments of NeoKidney® in ESRD Patients Treated With Short Daily Hemodialysis
NCT06024135 ·Status: UNKNOWN ·Phase: NA
-
Peritoneal Dialysis Versus Haemodialysis
NCT00752583 ·Status: COMPLETED ·Phase: NA
-
Protein-bound Uremic Retention Solutes and Long Nocturnal Hemodialysis: a Longitudinal Analysis
NCT00417339 ·Status: COMPLETED
-
Ellipsys Fistula for Hemodialysis Access
NCT03828253 ·Status: UNKNOWN
-
Role of Monocytes Adhesion and Vascular Lesions in Vascular Access Success or Failure in Uremic Patients
NCT03231410 ·Status: UNKNOWN
-
Hemodialysis in the Elderly (70yrs & Older)
NCT03065972 ·Status: UNKNOWN ·Phase: NA
-
A Single Arm sTudy to Evaluate the Effectiveness of EndoAVF in a Pre-dialysis Population (STEP Study)
NCT04633304 ·Status: UNKNOWN ·Phase: NA
-
Medico-economic Evaluation of the Creation of Arteriovenous Access for Hemodialysis Between Surgical Technique and Endovascular Technique in Patients with End-stage Renal Disease
NCT06679907 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Immediate Maintained Cannulation of a Newly Implanted Prosthetic Arteriovenous Access for Acute Hemodialysis
NCT00711750 ·Status: UNKNOWN
-
BONE ANCHORED PORT for Hemodialysis Treatment
NCT02069860 ·Status: TERMINATED ·Phase: NA
-
Reduction of Heparin Dose in Dialysis With Evodial System
NCT00781690 ·Status: COMPLETED ·Phase: NA
-
Clinical Evaluation of a Vascular Venous Anastomotic Connector [InterGraft VIG-only Study]
NCT02532621 ·Status: COMPLETED ·Phase: NA