The Use of a US-measured Styloid Process of the Distal Radius EET Diameter for Prediction of ETT Size
NCT06166927 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 100
Last updated 2025-03-24
Summary
This study will aim to test the accuracy of the ultrasonography measurement of the epiphyseal diameter of the distal radius in the prediction of the size of the cuffed and uncuffed ETT that best fits in children (1-6 years old) in comparison with the traditional age-based formulas.
Conditions
- Airway Management
Interventions
- DEVICE
-
Cuffed endotracheal tube
Patients will be intubated using a cuffed ETT with its OD determined by US measurement of the epiphyseal diameter of the distal radius.
- DEVICE
-
UnCuffed ETT
Patients will be intubated using an uncuffed ETT (Flexicare-UK) with its OD determined by US measurement of the epiphyseal diameter of the distal radius.
Sponsors & Collaborators
-
Assiut University
lead OTHER
Principal Investigators
-
Hala S Abdel-Ghaffar, MD · Assiut University
Eligibility
- Min Age
- 1 Year
- Max Age
- 6 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-01-10
- Primary Completion
- 2026-01-20
- Completion
- 2026-01-30
- FDA Device
- Yes
Countries
- Egypt
Study Locations
More Related Trials
-
Ultrasound-detectable Endotracheal Tube: a Feasibility Study
NCT05941013 ·Status: RECRUITING ·Phase: NA
-
Minimal Occlusive Pressure With Cuffed ETT: the Effect of Size on Intracuff Pressure
NCT02376101 ·Status: COMPLETED ·Phase: NA
-
Combining Electrical Impedance Tomography and Thoracic Ultrasound Toinvestigate Dynamic Changes
NCT06958770 ·Status: NOT_YET_RECRUITING
-
Loss-of-resistance Syringe Technique in Determining Endotracheal Cuff Pressure
NCT05828342 ·Status: COMPLETED
-
The Effect of Percutaneous Dilatational Tracheostomy on Intracranial Pressure
NCT06779877 ·Status: ACTIVE_NOT_RECRUITING
-
Comparison of Computertomography Scan, Electrical Impedance Tomography, and Ultrasound of the Lung in Infants
NCT04989439 ·Status: RECRUITING
-
the Diameter of Double-lumen Tube Measured by Different Methods
NCT05739318 ·Status: COMPLETED ·Phase: NA
-
ETT Cuff Leak: TV Ratios
NCT02768831 ·Status: COMPLETED ·Phase: NA
-
Airway Deadspace in Children: Air-Q Versus Endotracheal Tube
NCT03785977 ·Status: COMPLETED
-
Cuff Pressure Regulation Apparatus for Tracheal Intubation in Children
NCT04413318 ·Status: COMPLETED ·Phase: NA
-
Continuous Measurement of Intratracheal Pressure
NCT00866255 ·Status: COMPLETED ·Phase: NA
-
Cuff Pressure in Patients: Manometer vs Invasive Pressure Monitoring Setup
NCT01885793 ·Status: COMPLETED
-
Pediatric Positive End Expiratory Pressure (PEEP) Titration Using Electrical Impedence Tomography (EIT)
NCT06684119 ·Status: RECRUITING ·Phase: NA
-
Comparing Cardiac Output Measurements in Critically Ill Children Using USCOM and Transthoracic ECHO
NCT01460329 ·Status: COMPLETED
-
Does Diaphragm Electrical Activity Monitoring Predict Extubation Success in Children?
NCT06163183 ·Status: COMPLETED
-
Monitoring of Lung Ventilation Through Electrical Impedance Tomography During Pediatric Surgery
NCT06370507 ·Status: NOT_YET_RECRUITING
-
Study on the Correlation Between Tracheotomy Tip Pressure and Esophageal Pressure in Patients Weaned from Tracheotomy
NCT06783777 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Change In Diaphragmatic Thickness Predicts Extubation Success
NCT02656199 ·Status: TERMINATED
-
Shape and Dimensions of the Upper Airway in Infants Using Computed Tomography Imaging
NCT02925169 ·Status: COMPLETED
-
Comparison Between Two Endotracheal Tube Cuff Inflation Methods
NCT03902756 ·Status: COMPLETED ·Phase: NA
-
Continuous Regional Analysis Device for Neonate Lung
NCT02962505 ·Status: COMPLETED
-
Flow Sensor and Colourimetric Capnometer in Verifying Tracheal Tube Positioning in Term and Preterm Infants
NCT05162313 ·Status: UNKNOWN ·Phase: NA
-
Asymmetrical High Flow Nasal Cannula and End-Expiratory Lung Impedance
NCT06674629 ·Status: COMPLETED
-
The Role of Chest Electrical Impedance Tomography in the Pediatric Ventilator Weaning
NCT04011852 ·Status: COMPLETED
-
Effect of Electric Impedance Tomography-Guided PEEP Titration
NCT05736185 ·Status: COMPLETED ·Phase: NA