Effect of Albumin Versus Routine Care on Hemodynamic Response and Stability in Patients With Preeclampsia Guided by a Non-invasive Hemodynamic Monitoring System During Cesarean Delivery With Spinal Anesthesia

NCT06107335 · Status: NOT_YET_RECRUITING · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 62

Last updated 2024-12-06

No results posted yet for this study

Summary

The purpose of this study is to compare the effect of albumin versus routine care on hemodynamic response and stability in pre-eclamptic patients during cesarean delivery. The hypothesis is that volume replacement with albumin guided by stroke volume variation (SVV) using a ClearSight-Acumen (CS-A) monitor, before cesarean delivery (CD), improves hemodynamic stability in preeclamptic patients with severe features compared to routine care, under neuraxial anesthesia.

Conditions

  • Pre-Eclampsia

Interventions

DRUG

Human Albumin (colloid)

Fluid replacement will be achieved with colloid (5% albumin infusion). A bolus infusion of up to 500 milliliters (mL) of 5% Albumin will be administered prior to the placement of neuraxial anesthesia. If stroke volume variation (SVV) drops to less than 13% during the infusion of albumin, the infusion will be halted. At the completion of the placement of the spinal/combined spinal-epidural (CSE) anesthesia, study participants will receive the remaining albumin infusion if it was initially halted and SVV increases back to \>13% during the procedure (to a total maximum of 500 mL albumin for the entire procedure).

DRUG

Lactated Ringer's Injection (crystalloid)

Fluid restriction will be achieved with crystalloid (lactated ringer's injection) administered at a keep-the-vein-open (KVO) rate of 75 milliliters per hour (mL/hr), administered during the procedure.

DEVICE

Edwards HemoSphere monitor with ClearSight-Acumen finger cuff

Use of colloid will be guided by stroke volume variation (SVV) as assessed by the Edwards HemoSphere monitor with ClearSight-Acumen finger cuff device. The Edwards HemoSphere monitor with ClearSight-Acumen (CSA) finger cuff is a hemodynamic monitoring system that obtains continuous blood pressure readings from a cuff on the finger. In study participants, the finger cuff will be placed on the middle finger of one of the hands. The Edwards device can be used to predict impending intraoperative hypotension before its occurrence. The device has the ability to assess vasodilatory status using systemic vascular resistance (SVR), volume status using stroke volume variation (SVV) and stroke volume (SV) and the use of Carbon Monoxide (CO) to assess for underlying cardiac suppression. It also incorporates the hypotension prediction index (HPI), an algorithm that uses the arterial waveform to predict early phases of intraoperative hypotension.

Sponsors & Collaborators

  • The University of Texas Health Science Center, Houston

    lead OTHER

Principal Investigators

  • Onyi Onuoha, MD, MPH · The University of Texas Health Science Center, Houston

Study Design

Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
FEMALE
Healthy Volunteers
No

Timeline & Regulatory

Start
2025-07-01
Primary Completion
2026-12-01
Completion
2026-12-01
FDA Drug
Yes
FDA Device
Yes

Countries

  • United States

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT06107335 on ClinicalTrials.gov