Migration of CS vs CR Insert in TKA Using RSA
NCT05936593 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 44
Last updated 2023-12-18
Summary
Background:
The choice whether or not to preserve the posterior cruciate ligament (PCL) in total knee arthroplasty (TKA) is coupled to the us of a PCL-retaining (CR) or a condylar (CS) insert. The CS insert is anterior-lipped (AL) to prevent anterior translation of the femur on the tibia with flexion and compensate the function of the PCL. Currently both the CR and CS insert are made of highly cross-linked polyethylene (HXPLE) to theoretically reduce wear related osteolysis. However, this also might diminish the fracture toughness and crack propagation of the insert. The investigators expect that due to the high contact forces on the anterior lip of the CS insert during flexion, especially in younger and more active patients, and the lower fracture toughness of HXPLE, the CS insert insert might show more migration, wear or other damage compared to the CR insert in the long-term, which might lead to more revisions in the CS insert compared to the CR insert.
To measure the migration and wear, during surgery tantalum markers will be inserted in the host bone using a marker inserter. The displacement of the prosthesis with reference to the host bone will be measured using model-based RSA. Both tantalum markers ande the inserter are already used for study purposes. However, the safety and usability are not registered before.
Objective:
The primary objective is to compare the migration of both the femoral and tibial component by the use of a CS insert or CR insert both made of HXPLE using model-based roentgen stereophotogrammetric analysis (mRSA). Furthermore, the safety and usability of the tantalum markers and the marker inserter will be determined. The secondary objective is to determine the influence of the type of insert on the wear, inducible displacement, survival and clinical outcomes.
Study design:
A randomized controlled trial
Study population:
Forty-four patients scheduled to undergo primary total knee replacement, aged below 70 years with an ASA-score of 1 or 2 will be needed in total, divided in two groups of 22 patients each.
Intervention:
One group receives an uncemented TKP with a CS insert, while the other group receives an uncemented TKP with a CR insert. Both will be placed using the MAKO-robotic arm using a kinematic balancing technique.
Outcomes:
Main study parameters are migration of the femoral and tibial components measured with model-based RSA software till 10 years postoperatively. Furthermore, the stability of the markers will be determined and the complications due to the markers and/or the marker inserter will be registered. The secondary parameters are wear, inducible displacement, survival, clinical outcomes and complications up to 10 years postoperatively.
Conditions
- Wear of Articular Bearing Surface of Prosthetic Joint
- Migration of Implant
Interventions
- DEVICE
-
Condylar Stabilizing (CS) insert
During TKA surgery a Condylar Stabilizing (CS) insert is implanted and tantalum beads are placed around the prosthesis.
- DEVICE
-
Cruciate Retaining (CR) insert
During TKA surgery a Cruciate Retaining (CR) insert is implanted and tantalum beads are placed around the prosthesis.
Sponsors & Collaborators
-
Reinier Haga Orthopedisch Centrum
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-07-21
- Primary Completion
- 2035-06-30
- Completion
- 2035-06-30
Countries
- Netherlands
Study Locations
More Related Trials
-
All-poly Versus Metal-backed
NCT04358601 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
A Prospective Study to Evaluate the iTotal Knee and iPoly XE Tibial Inserts
NCT03289754 ·Status: TERMINATED ·Phase: NA
-
Uncemented Tritanium Compared With Cemented Metal-backed Tibia Components in Total Knee Replacement
NCT02578446 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Antibiotic Loaded Cement After TKA
NCT05429671 ·Status: COMPLETED ·Phase: PHASE3
-
RSA RCT: Attune RP TKA Versus LCS RP TKA
NCT03101007 ·Status: COMPLETED ·Phase: NA
-
Comparison of A Mobile-Bearing Total Knee System With A Fixed-Bearing Total Knee System In Cemented Total Knee Arthroplasty
NCT00589108 ·Status: COMPLETED ·Phase: NA
-
TKA Operating Room Efficiency for TKA Using Customized Implant Techniques
NCT04180423 ·Status: TERMINATED
-
Survivorship and Outcomes of Robotic-Arm Assisted Medial Unicompartmental Knee Arthroplasty
NCT03668717 ·Status: ACTIVE_NOT_RECRUITING
-
A Multicenter Study to Evaluate Functional Outcome After Knee Replacement
NCT02494544 ·Status: TERMINATED ·Phase: NA
-
Total Knee Arthroplasty (TKA) Cemented Versus Cementless Tibial Prosthesis Study
NCT01041937 ·Status: COMPLETED ·Phase: NA
-
I-beam and Cruciate Tibial Components Used in Total Knee Replacement
NCT00588783 ·Status: TERMINATED
-
Kinematic Alignment vs Mechanical Alignment for Total Knee Arthroplasty
NCT05461638 ·Status: WITHDRAWN ·Phase: NA
-
Patellar Resurfacing Versus Patellar Retention in Total Knee Arthroplasty - A Randomized Clinical Trial
NCT01500252 ·Status: COMPLETED ·Phase: PHASE4
-
All-Polyethylene Tibias in TKA: PS vs CS Implants
NCT03569670 ·Status: WITHDRAWN ·Phase: NA
-
The Efficacy of Using CR and PS Prosthesis in Total Knee Replacement
NCT03877042 ·Status: UNKNOWN ·Phase: NA
-
Do Corticosteroid Injections During Total Knee Replacement Improve Early Clinical Results?
NCT00492973 ·Status: COMPLETED ·Phase: NA
-
Bilateral Total Knee Arthroplasty vs Unicompartment Arthroplasty Retrospective and Clinical Outcome Study
NCT02583113 ·Status: WITHDRAWN
-
A Prospective, Randomized, Controlled Study Comparing Three Tibial Component Designs in Total Knee Arthoplasty
NCT00589147 ·Status: COMPLETED ·Phase: NA
-
Physica System Total Knee Replacement Registry Study
NCT03048201 ·Status: RECRUITING ·Phase: NA
-
The Importance of Different Modularity of the Polyethylene Insert for Tibial Component Migration and Adaptive Bone Remodeling After Uncemented Total Knee Arthroplasty Using Trabecular Metal Technology (TMT) Zimmer NexGen®, (Monoblock vs. Modular Design)
NCT01637051 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Assessment of Conventional and Patient-specific Instrumentation in Total Knee Arthroplasty
NCT02230215 ·Status: COMPLETED ·Phase: NA
-
A Randomized Control Trial to Assess Early Clinical and Functional Outcome of the ROCC and LCS Total Knee Implant Designs
NCT00755144 ·Status: COMPLETED ·Phase: NA
-
Roentgen Stereophotogrammetric Analysis (RSA) Trial Comparing Trabecular Metal Monoblock and Modular Tibial Components
NCT01180595 ·Status: COMPLETED ·Phase: PHASE4
-
A Roentgen Stereophotogrammetric Analysis on Migration of Knee Prostheses.
NCT00138853 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Two Surgical Strategies for Robotic Implantation of Total Knee Prostheses (Stryker), Cemented Versus Uncemented
NCT04692714 ·Status: RECRUITING ·Phase: NA