Uncemented Tritanium Compared With Cemented Metal-backed Tibia Components in Total Knee Replacement
NCT02578446 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 72
Last updated 2025-09-04
Summary
The optimal method of total knee replacement component fixation to the bone remains a challenge. The use of bone cement is considered the gold standard and is the preferred technique for most surgeons. However, uncemented fixation methods have been developed in an attempt to tackle problems that can be seen when cement is used. The cement-bone interlock can deform and degrade over the years and can lead to aseptic loosening, especially in young and active patients. A loosened prosthesis results in an impaired functioning and painful knee in daily life for which a revision of the prosthesis may be necessary. To prevent aseptic loosening and subsequent revision surgery, new methods of uncemented fixation have been developed.
One of these methods is to use a highly porous metal called Tritanium®. It can improve the biologic fixation by resembling the characteristics of trabecular bone. It is expected that this surface aids bone ingrowth and to have similar or even better results concerning early fixation properties and long-term durability compared with cemented fixation. Excellent results using this highly porous Tritanium have been seen in total hip surgery already.
This single-blinded, randomized clinical trial will assess clinical and radiological outcomes including Roentgen Stereophotogrammetry (RSA) measurements of a newly approved uncemented Triathlon Tritanium CR total knee prosthesis compared with a standard cemented Triathlon metal-backed CR total knee prosthesis (both by Stryker Orthopaedics). Two arms of each 35 patients will be included.
The primary outcome measure will be prosthetic migration after two years of the uncemented Triathlon Tritanium CR Total Knee and the cemented Triathlon CR Total Knee by means of RSA. It is hypothesized that the new uncemented Tritanium prosthesis will perform at least equally good in terms of migration and clinical parameters compared with the standard cemented Triathlon.
The secondary outcome measure will be long-term (10-year) survival based on the two-year migration patterns combined with clinical factors and radiographic aspects. In order to identify other clinical parameters besides the fixation of the prosthesis components, clinical scores and radiographic aspects will be correlated with the RSA outcome. The 10-year results will be used to verify the predicted long-term survival results.
Conditions
- Arthroplasty
- Replacement
- Knee
Interventions
- DEVICE
-
Uncemented Triathlon Tritanium CR Total Knee System
Primary Total Knee Replacement
- DEVICE
-
Cemented Triathlon CR Total Knee System
Primary Total Knee Replacement
Sponsors & Collaborators
-
Leiden University Medical Center
collaborator OTHER -
Stryker Orthopaedics
collaborator INDUSTRY -
Region Skane
lead OTHER
Principal Investigators
-
Sören Toksvig-Larsen, Ass Prof · Department of Orthopaedics Hässleholm-Kristianstad-Ystad, Hässleholm Hospital
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2015-10-31
- Primary Completion
- 2019-03-31
- Completion
- 2027-03-31
Countries
- Netherlands
- Sweden
Study Locations
More Related Trials
-
Fluoroscopic and RSA Evaluation of the Triathlon Total Knee Prosthetic Design
NCT02924961 ·Status: TERMINATED ·Phase: NA
-
Cemented vs Cementless TKA
NCT03683992 ·Status: COMPLETED
-
A Prospective Radiostereometric Analysis (RSA) and Clinical Evaluation of the Triathlon Tritanium Total Knee Replacement
NCT02373761 ·Status: UNKNOWN
-
Cementless Triathlon 5YR Follow-Up
NCT05877261 ·Status: COMPLETED
-
Clinical Outcome Study for the Triathlon Cruciate Retaining (CR) Total Knee
NCT02535741 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Two Surgical Strategies for Robotic Implantation of Total Knee Prostheses (Stryker), Cemented Versus Uncemented
NCT04692714 ·Status: RECRUITING ·Phase: NA
-
Stryker Triathlon® Cruciate Substituting vs. Posterior Stabilized Outcomes Study
NCT01367925 ·Status: COMPLETED
-
Triathlon Tritanium Cone Augments Outcomes Study
NCT02521103 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Simplex High Viscosity Bone Cement in Primary Total Knee Arthroplasty
NCT02572310 ·Status: COMPLETED ·Phase: NA
-
Total Knee Arthroplasty (TKA) Cemented Versus Cementless Tibial Prosthesis Study
NCT01041937 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Triathlon - A New Total Knee Prosthesis System - Roentgen Stereophotogrammetric Analysis (RSA) Triathlon CR vs. PS
NCT02522728 ·Status: COMPLETED ·Phase: NA
-
Triathlon All-Polyethylene Tibia Outcomes Study
NCT04636190 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
I-beam and Cruciate Tibial Components Used in Total Knee Replacement
NCT00588783 ·Status: TERMINATED
-
Evaluation of Triathlon - A New Total Knee Prosthesis System - Triathlon PA vs. Triathlon Pressfit
NCT03198533 ·Status: COMPLETED ·Phase: NA
-
Migration of CS vs CR Insert in TKA Using RSA
NCT05936593 ·Status: RECRUITING ·Phase: NA
-
Roentgen Stereophotogrammetric Analysis (RSA) and Dual Energy X-ray Absorptiometry (DEXA) to Evaluate Fixation of Periapatite Coated Triathlon Total Knee Arthroplasty (TKA) Components
NCT01180582 ·Status: COMPLETED ·Phase: NA
-
All-poly Versus Metal-backed
NCT04358601 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Post-marketing Surveillance Study of the Triathlon Tritanium Baseplate
NCT02905097 ·Status: UNKNOWN
-
Tritanium® Study in Japan
NCT02552069 ·Status: UNKNOWN
-
A Prospective, Randomized Study Comparing Cemented and Cementless Total Knee Replacement
NCT01194817 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Bone Mineral Density Changes Under Two Tibial Components in Total Knee Arthroplasty
NCT01764984 ·Status: COMPLETED ·Phase: PHASE4
-
Analysis of Competitive Posterior Cruciate Retaining (PCR) and Posterior Stabilized (PS) Total Knee Arthroplasty (TKA)
NCT04321356 ·Status: COMPLETED
-
X-3 Polyethylene Survival Outcomes Study
NCT00493792 ·Status: COMPLETED ·Phase: NA
-
Triathlon® Cruciate Retaining (CR) Total Knee System Outcomes Study
NCT00957723 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Triathlon - A New Total Knee Prosthesis System - RSA Triathlon Standard vs. Short Keel
NCT02525614 ·Status: COMPLETED ·Phase: NA