Feasibility Evaluation - Blood Glucose Level Monitoring by Microwave Metamaterial Sensor in Blood Samples.
NCT05929196 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 21
Last updated 2024-02-28
Summary
The goal of this clinical trial is to test microwave metamaterial glucose sensor on blood samples. It means to compare the results of glucose values obtained by microwave metamaterial sensor and by standard biochemical analyzer.
Conditions
Interventions
- DIAGNOSTIC_TEST
-
In vitro full blood diagnostic test.
Participant will donate approximately 5 ml blood sample. Later in a laboratory the sample will be processed in the microwave metamaterial sensor for non invasive blood glucose monitoring and standard biochemical analyzer. Specific dielectric properties and scattering parameters will be measured for blood glucose level determination.
Sponsors & Collaborators
-
Czech Technical University in Prague
lead OTHER
Principal Investigators
-
Luděk Šprongl, Ing. · Regional hospital in Kladno
-
Lukáš Malena, Ing. · Czech Technical University in Prague
-
David Vrba, doc. · Czech Technical University in Prague
Study Design
- Allocation
- NA
- Purpose
- BASIC_SCIENCE
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-07-12
- Primary Completion
- 2023-07-17
- Completion
- 2023-09-01
Countries
- Czechia
Study Locations
More Related Trials
-
Assessment of Blood Glucose Monitoring Devices With New Insight Features
NCT02929654 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Glucose Monitoring Methods: Characterizing Glycemic Control in Subjects With Diabetes
NCT00805506 ·Status: COMPLETED
-
Effectiveness and Safety Study of the Dexcom G4™ Continuous Glucose Monitoring System
NCT01514292 ·Status: COMPLETED ·Phase: NA
-
Measurement Algorithm Control and Optimization With Subsequent Performance Evaluation of Sanmina Non-invasive Biosensors During a Standardized Meal Test in Patients With Diabetes Mellitus Type 1 and Type 2
NCT04379427 ·Status: COMPLETED ·Phase: NA
-
Effects of Novel Flash Glucose Monitoring System on Glycemic Control in Adult Patients With Type 1 Diabetes Mellitus
NCT03522870 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Glunovo Real-Time Continuous Glucose Monitoring in Adults With Type 2 Diabetes
NCT07089979 ·Status: COMPLETED ·Phase: NA
-
Self-monitoring of Blood Glucose in Insulin-treated Patients With Type 2 Diabetes
NCT01460459 ·Status: UNKNOWN ·Phase: NA
-
Standardized Procedure for the Assessment of New-to-market Continuous Glucose Monitoring Systems
NCT01751932 ·Status: COMPLETED ·Phase: NA
-
Effect of Paired Testing to Poorly Controlled Chinese Diabetes on Glycemic Control and Self Care
NCT02225691 ·Status: UNKNOWN ·Phase: NA
-
To Evaluate the Efficacy and Safety of Multi-parameter Non-Invasive Glucose Sensors for for Blood Glucose Measurement
NCT06017349 ·Status: COMPLETED ·Phase: NA
-
Effect of "Therapeutic Monitoring" on Blood Glucose Control in Type 2 Diabetes
NCT04164784 ·Status: UNKNOWN ·Phase: NA
-
PRECISE: A Prospective, Multi-Center Evaluation of the Accuracy of a Novel Continuous Implanted Glucose Sensor
NCT02154126 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a Single Center Expansion of Continuous Glucose Monitor Access in Patients With Type 2 Diabetes
NCT05200390 ·Status: UNKNOWN ·Phase: NA
-
Prospective Observational Study Assessing Treatment and Outcomes of Patients With Prediabetes
NCT01869101 ·Status: UNKNOWN
-
Performance Evaluation of a Non-Invasive Glucose Monitor as Compared to CGM Data Acquired by the iPro2
NCT01831752 ·Status: COMPLETED
-
Effectiveness and Safety Study of the Dexcom G4 Platinum With Modified Algorithm
NCT02087995 ·Status: COMPLETED ·Phase: NA
-
Feasibility Study to Assess the Safety and Functionality of the GluSense Continuous Glucose Monitor in Diabetic Patients
NCT01198678 ·Status: COMPLETED ·Phase: PHASE1
-
Customer Outcomes & Value Experiencing A New Monitoring Technology
NCT04262700 ·Status: UNKNOWN ·Phase: NA
-
The Evaluation of Laser Lancing Devices in Adult Type 2 Diabetes Patients
NCT05251506 ·Status: UNKNOWN ·Phase: NA
-
Clinical Evaluation of Non-invasive Blood Glucose Meter
NCT06796322 ·Status: RECRUITING ·Phase: NA
-
Comparison Study of Lay Person Finger Stick Versus Blood Draw
NCT01913145 ·Status: COMPLETED ·Phase: PHASE1
-
Assessment of Blood Glucose Monitoring Systems
NCT01909687 ·Status: COMPLETED ·Phase: NA
-
Clinical and Home Use Feasibility Study of a Percutaneous Optical Glucose Fiber Sensor
NCT04152408 ·Status: COMPLETED ·Phase: NA
-
System Accuracy of 14 Blood Glucose Monitoring Systems
NCT06037499 ·Status: COMPLETED ·Phase: NA
-
Food Design for Improved Day-long Glycaemic Regulation
NCT02876029 ·Status: COMPLETED ·Phase: NA