Comparison of Cardiac Resynchronisation Therapy (CRT) Response Using High Frequency (HF) - ECG or Q-LV Guided Optimisation for Left Ventricular, Pacing Site.
NCT05829876 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 180
Last updated 2024-08-21
Summary
The research aims to compare the response of Cardiac Resynchronisation Therapy (CRT) using HF ECG guided or the conventional method of Q-LV measurement guided optimisation for left ventricular, pacing site.
Conditions
Interventions
- OTHER
-
High Frequency ECG Mapping
A high frequency ECG map will be performed to assess the optimum left ventricular pacing site.
- OTHER
-
Q-LV Measurement
Measurement of Q wave on 12 lead ECG to LV stimulus to assess optimum left ventricular pacing site.
Sponsors & Collaborators
-
University Hospital Birmingham
lead OTHER
Principal Investigators
-
Jamie Walton, BSc · University Hospitals Birmingham
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 100 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-10-31
- Primary Completion
- 2025-07-31
- Completion
- 2025-07-31
Countries
- United Kingdom
Study Locations
More Related Trials
-
Echocardiography and Peak Endocardial Acceleration (PEA) Measurements in Cardiac Resynchronization Therapy (CRT)
NCT01066078 ·Status: COMPLETED
-
Magnetocardiography (MCG) Parameters in the Prediction of Future ICD Therapy
NCT04352816 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
3D Echocardiographic Assessment of Epicardial Pacing After Cardiopulmonary Bypass.
NCT02842762 ·Status: UNKNOWN ·Phase: NA
-
Comparative Study to Examine Whether Echocardiography Performed During Cardiac Resynchronization Therapy Device Implantation Can Improve the Response Rate
NCT01014000 ·Status: WITHDRAWN ·Phase: NA
-
LV Endocardial CRT for Patients With Intermediate QRS Width
NCT03573427 ·Status: WITHDRAWN
-
Left Ventricular Dysfunction in Critically Ill Patients
NCT03787810 ·Status: COMPLETED
-
Diagnosis of HCM With AI-ECG
NCT06287892 ·Status: RECRUITING
-
The Effect of Left Ventricular Filling Pressure on Pulmonary Clearance of Free Radical Loaded White Blood Cells and Platelets in Congestive Heart Failure Patients Before and After Biventricular Pacing
NCT00716885 ·Status: UNKNOWN
-
Artificial Intelligence (AI) Analysis of Synchronized Phonocardiography (PCG) and Electrocardiogram(ECG)
NCT06009718 ·Status: RECRUITING
-
Real-time Continuous Cardiac Output Measurements
NCT04774978 ·Status: UNKNOWN ·Phase: NA
-
Echocardiographic Evaluation of RV Injury in the ICU
NCT05525936 ·Status: NOT_YET_RECRUITING
-
Automated Ultrasound Cardiac Guidance Tool
NCT05649826 ·Status: RECRUITING
-
The Diagnosis and Treatment System of Transesophageal Echocardiography in ICU
NCT03811730 ·Status: UNKNOWN ·Phase: NA
-
Sleep Apnea, Arrhythmias and Cardiac Reverse Remodeling in Heart Failure Patients
NCT02870647 ·Status: WITHDRAWN ·Phase: PHASE4
-
Left Ventricular Fibrosis in Chronic Kidney Disease
NCT03176862 ·Status: UNKNOWN
-
Multi Point Pacing vs. Conventional STUDY PROTOCOL
NCT04334018 ·Status: WITHDRAWN ·Phase: NA
-
Guided Placement of CRT-Leads
NCT00764075 ·Status: COMPLETED ·Phase: NA
-
Enhanced Diagnosis of Ventricular Activation Pattern Using Intracardiac Electrograms
NCT02057588 ·Status: COMPLETED ·Phase: NA
-
Non-invasive Mapping Using Ultra-high Frequency Electrocardiography
NCT04537455 ·Status: COMPLETED ·Phase: NA
-
Prospective Registry of Epicardial LV Leads Placed During Cardiac Surgery Procedures
NCT00288288 ·Status: COMPLETED
-
Hemodynamic Measurements During Liver Transplantation
NCT00682110 ·Status: COMPLETED
-
Optimization of an Automated Ultrasound Cardiac Guidance Tool
NCT04981444 ·Status: COMPLETED
-
Safety and Efficacy Study of AI LVEF
NCT05140642 ·Status: COMPLETED ·Phase: NA
-
Use of 3-D Blood Pool Scintigraphy to Guide Left Ventricular Pacing Lead Placement in Patients Requiring Cardiac Resynchronization Therapy
NCT02669290 ·Status: TERMINATED ·Phase: NA
-
Comparability of Hemodynamic Parameters Measured by Non-invasive Echocardiography and by Right Heart Catheterization
NCT03231774 ·Status: COMPLETED