The Right Amount of Purge Useful for Blood Sampling on PiccLine (PiccLine)
NCT05763186 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 66
Last updated 2025-05-21
Summary
An increasing number of patients are receiving central lines, including PiccLine systems for the administration of therapeutics and nutrition.
Although these systems are not theoretically intended for blood collection, nurses prefer them as a puncture site when they are in place in their patients, saving them from further peripheral puncture in people who generally do not have optimal venous capital.
It is essential to purge the tubing in place in the patient and filled with infusion solution before drawing blood. Although the dead volume of the tubing used does not exceed 2mL, the volume of purging required before filling tubes for the laboratory appears to be much greater. Anecdotal evidence suggests a useful volume of 20ml but this has never been clearly demonstrated. In addition, the Biochemistry laboratory regularly sees blood samples diluted with perfusion solution, as evidenced by biochemical assays, leading to the cancellation of analyses received in the laboratory and a new sample being taken. This increases blood spoliation for these often already anaemic patients.
There is no consensus in the literature on recommendations for such sampling in PiccLine patients:
* The CLSI1 (Clinical and Laboratory Standart Institute), a non-governmental organisation, issued sampling recommendations in 2017 that were taken up by Becton Dickinson2, a supplier of blood collection tubes. These recommendations include:
* Rinse with 10 ml of 0.9% NaCl
* Then a purge of 3 to 11 ml (depending on the analysis sought)
* English-language articles3,4,5,6,7 show purge volumes ranging from 3 to 6 ml with significantly different sampling methods (rinsing or not).
The investigators therefore note a discrepancy between the sampling practices of the university hospital and the recommendations of the CLSI. In fact, the investigators noted a lack of rinsing prior to purging, which could explain the difference between 20 and 3 ml. This raises the issue of protocolisation of this type of sampling in order to standardise practices.
A consultation of other hospitals, carried out beforehand, enabled us to note that French practices are not in agreement with these recommendations. The management of the Rennes University Hospital as well as the Haute Autorité de Santé were contacted in order to confirm that no normative document had been published or was being drafted on this subject.
The fields of study are: sampling practices on PiccLine, the pre-analytical phase in medical biology.
Conditions
Interventions
- OTHER
-
Sampling
Comparison of the results of the biological examinations obtained on the 6 tubes collected on the PiccLine with the results of the biological examinations obtained on the peripheral sample.
- OTHER
-
Sampling and rinsing
Comparison of the results of the biological examinations obtained on the 6 tubes collected on the PiccLine with the results of the biological examinations obtained on the peripheral sample.
Sponsors & Collaborators
-
Rennes University Hospital
lead OTHER
Principal Investigators
-
Eric Geffray · CHU Rennes
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2024-05-18
- Primary Completion
- 2025-11-30
- Completion
- 2026-05-31
Countries
- France
Study Locations
More Related Trials
-
Observational Study of Complications Related to Use of Peripherally Inserted Central Catheters
NCT01578993 ·Status: COMPLETED
-
Safety and Efficacy of Midline and PICC
NCT03502980 ·Status: COMPLETED ·Phase: NA
-
A Difference in Subclavian Vein Catheterization Between Supine and Lateral Tilt Position - Stage I
NCT03296735 ·Status: UNKNOWN ·Phase: NA
-
PIcc Cost EffectiveneSS and Safety of Infusional Therapy
NCT03392831 ·Status: UNKNOWN ·Phase: NA
-
Research on the Application of Blood Collection Through Midline Catheters of Different Lengths
NCT06014099 ·Status: COMPLETED ·Phase: NA
-
Study of Complication Rates Associated With PICC for Left vs Right
NCT01638702 ·Status: COMPLETED ·Phase: NA
-
"Follow-up of Midlines Placed Outside the Intensive Care Unit: What Side Effects? An Observational Study"
NCT04131088 ·Status: COMPLETED
-
Impact of a Task Delegation to ICU Nurses for Midlines' Placement
NCT04155723 ·Status: COMPLETED
-
Comparison of Heparin Anti-Xa Activity From Central Venous Catheter Samples Using a 5 mL Syringe Flush or a Vacuum Tube Flush Versus Peripheral Vein Samples in ICU Patients
NCT07183605 ·Status: RECRUITING ·Phase: NA
-
Efficacy of Ben-Guard Garment in Reducing Pediatric Central Line Complications
NCT05109338 ·Status: COMPLETED ·Phase: NA
-
Comparison of Two Peripheral Inserted Intravenous Catheters
NCT04140916 ·Status: COMPLETED ·Phase: NA
-
CATCH - Catheter Infections in Children
NCT01029717 ·Status: COMPLETED ·Phase: PHASE3
-
The Influence of Nursing Technique Applied at the Central Venous Catheter Insertion Site Upon the Incidence of Infection
NCT03875352 ·Status: COMPLETED ·Phase: NA
-
The Application of Neck Ultrasound in the Assessment of Peripherally Inserted Central Catheter (PICC) Tip Position
NCT00565877 ·Status: COMPLETED ·Phase: NA
-
Ideal Depth of Guide Wire for Central Catheterization
NCT02711761 ·Status: COMPLETED ·Phase: NA
-
Comparison of Ultrasound-guided Central Venous Catherterization Via the Lower Internal Jugular Vein or the Subclavian Vein
NCT03162757 ·Status: COMPLETED ·Phase: NA
-
The Relationship Between the Lack of AT-Ⅲ, PC, PS Activity and PICC-related Thrombosis
NCT04535206 ·Status: UNKNOWN
-
Monitoring the Peripheral Intravenous Infusion Site for Infiltration and Extravasation
NCT01476293 ·Status: COMPLETED
-
A Difference in Subclavian Vein Catheterization Between Supine and Lateral Tilt Position - Stage II
NCT03303274 ·Status: UNKNOWN ·Phase: NA
-
Comparison Between Initial Routine PICC and General IV Access in Terminally Ill Cancer Patients
NCT03299868 ·Status: COMPLETED ·Phase: PHASE2
-
Evaluation of Accuvein in Adult Patients
NCT01020461 ·Status: TERMINATED ·Phase: PHASE4
-
Infusion Flow Rates and Blood Sampling
NCT02021617 ·Status: UNKNOWN ·Phase: NA
-
Antegrade Versus Retrograde IV for Blood Draws
NCT03533777 ·Status: COMPLETED ·Phase: NA
-
Peripherally Inserted Central Catheter (PICC) Thrombosis: Reverse Taper Versus Non-tapered Catheters
NCT00728819 ·Status: COMPLETED ·Phase: NA
-
Central Venous Catheter-related Complications in Patients Under Anticancer Treatment
NCT05455866 ·Status: UNKNOWN