Head Elevated Position and Hyper-angulated Video-laryngoscope Guided Intubation
NCT05671978 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 182
Last updated 2026-01-29
Summary
Cervical immobilization with manual in-line stabilization (MILS) is recommended to prevent further neurologic injury during intubation in patients with known or suspected cervical spine injuries. However, MILS is associated with increased rates of failed tracheal intubation using direct laryngoscopy, because the restriction of neck flexion and head extension may prevent adequate alignment of the oral, pharyngeal, and tracheal axes, hence adversely affecting laryngeal visualization during direct laryngoscopy.
The GlideScope® (Verathon, Bothell, WA, USA) is a videolaryngoscope with an hyer-angulated blade (HA-VL), which is characterized by a sharper curvature than the Macintosh blade. The large curvature of the HA-VL allows seeing 'round the corner', which can provide indirect laryngeal visualization even with restricted neck movements . However, the HA-VL also prevents direct visualization of larynx, which make it difficult to guide the tracheal tube (TT) towards the glottis despite obtaining a good laryngeal view. Thus, the good view of the laryngeal inlet provided by videolaryngoscopes does not always lead to an easy or successful intubation. There are numerous reports in the literature of devices managing to achieve an improvement in view but still being unable to pass an TT to laryngeal inlet. Thus, the key to a successful tracheal intubation using HA-VL lies not in the laryngeal view obtained but in the ease of inserting the TT. Recent meta studies comparing alternative intubation devices with the standard Macintosh laryngoscope in subjects with cervical spine immobilization reported that GlideScope® was associated with improved glottis visualization but no statistically significant differences in intubation failure or time to intubation compared with direct laryngoscopy.
The sniffing position recommended for direct laryngoscopy has been reported to interfere with successful tracheal intubation with HA-VL because flexion of the neck narrows the angle between the sternum and the chin, making it more difficult to insert the HA-VL blade into mouth. In contrast, placing the patient in a 'neutral' or 'back-up head-elevated (BUHE)' position was not associated with a higher incidence of difficult laryngoscope with HA-VL. Given that the 'BUHE' position, when compared with the regular supine position, extend the safe apnoea time during direct laryngoscopy, this position seems better suited for HA-VL than neutral position. However, there is currently insufficient evidence to recommend a specific patient position for the use of HA-VL.
Previous studies using magnetic resonance imaging (MRI) suggests that head elevation until the external auditory meatus and sternal notch (AM-S) are in the horizonal plane leads to better anatomic alignment of the pharyngeal and laryngeal axes. Investigators therefore hypothesized that BUHE position (to align the AM-S in horizontal plane), compared with neutral position, would allow a relatively straight passage which makes it easier to guide the TT into the laryngeal inlet (facilitates insertion of TT into the laryngeal entrance) during HA-VL guided intubation. To compare the effect of the BUHE position and the neutral position on the ease of tracheal intubation using a HA-VL (GlideScope®), MILS was applied to patients without any known or suspected neck pathology as a way of simulating a difficult airway. The primary outcome was the tracheal intubation time with both positions. Secondary outcomes examined included rates of successful tracheal intubation and intubation success rate, number of intubation attempts, heart rate responses during intubation, and handling of the Glidesope VL after alignment of the EAM and sternal notch.
Conditions
- Intubation; Difficult or Failed
Interventions
- PROCEDURE
-
back-up head elevated position
The patient was then placed in the back-up head elevated position to align the external auditory meatus and sternal notch, which was achieved by breaking the operating table
- PROCEDURE
-
neutral position
The patient was then placed in the netural position
Sponsors & Collaborators
-
Hallym University Kangnam Sacred Heart Hospital
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- QUADRUPLE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-01-16
- Primary Completion
- 2023-07-31
- Completion
- 2023-07-31
Countries
- South Korea
Study Locations
More Related Trials
-
Cervical Spine Motion During Tracheal Intubation: Video Laryngoscope vs Rigid Video Stylet
NCT03120546 ·Status: COMPLETED ·Phase: NA
-
Repositioning Method for Left-sided Double Lumen Tubes
NCT01371773 ·Status: COMPLETED ·Phase: NA
-
C-MAC Videolaryngoscope Intubation and Cervical Spine Motion
NCT03567902 ·Status: UNKNOWN ·Phase: NA
-
Prehospital Tracheal Intubation Technique Using Initial Direct Laryngoscopy During Videolaryngoscopy
NCT06918717 ·Status: COMPLETED ·Phase: NA
-
Comparison of Laryngeal Mask and I-gel to Laryngoscope by Novice Operators in Simulated Difficult Airway
NCT02224027 ·Status: UNKNOWN ·Phase: NA
-
Hybrid Intubation Technique for Difficult Airway Children
NCT06058221 ·Status: RECRUITING ·Phase: NA
-
Head and Neck Positions for Endotracheal Intubation Using a Videolaryngoscope
NCT05128968 ·Status: COMPLETED ·Phase: NA
-
Tracheal Intubation Using Videolaryngoscope vs Fiberoptic Bronchoscope in Patients With Cervical Immobilization
NCT03759561 ·Status: COMPLETED ·Phase: NA
-
The Influence of Degree of Head Elevation on Insertion Success for ProSeal Laryngeal Mask Airway Insertion
NCT02058030 ·Status: COMPLETED ·Phase: NA
-
Comparison of Efficiency Between I-gel Blind Intubation and I-gel Bronchoscopic Intubation During Resuscitation
NCT02411422 ·Status: COMPLETED ·Phase: NA
-
The Influence of Head and Neck Position on the Oropharyngeal Leak Pressure Using Air-Q SP Airway
NCT02402387 ·Status: COMPLETED ·Phase: NA
-
Effect of Head Elevation on LMA Insertion
NCT04229862 ·Status: COMPLETED ·Phase: NA
-
Optimal Head and Neck Position for Videolaryngoscopy
NCT03810937 ·Status: UNKNOWN ·Phase: NA
-
Determining the Depth of Endotracheal Tube Insertion
NCT02158247 ·Status: COMPLETED
-
Long Endotracheal Tube vs. Aintree Intubating Catheter for Fiberoptic-guided Intubation in Manikin
NCT03645174 ·Status: COMPLETED ·Phase: NA
-
Double-lumen Tube Intubation Technique to Reduce Laryngeal Injuries
NCT01441362 ·Status: COMPLETED ·Phase: NA
-
Laryngoscope-assisted Lightwand Intubation and Cervical Spine Motion
NCT02430415 ·Status: UNKNOWN ·Phase: NA
-
Predictive Factors for Successful Videolaryngoscopic Intubation Without Stylet
NCT05968781 ·Status: COMPLETED
-
Mallampati Classification vs Best Visible Mallampati for Prediction of Difficult Tracheal Intubation
NCT02788253 ·Status: COMPLETED
-
Head Position on Pediatric Nasotracheal Intubation
NCT05164276 ·Status: COMPLETED ·Phase: NA
-
Effect of Head-neck Rotation on I-gel™ Insertion
NCT05201339 ·Status: COMPLETED ·Phase: NA
-
Tracheal Intubation in Patient With Semi-rigid Collar Immobilization of the Cervical Spine: A Comparison of Fiberoptic Bronchoscope Assisted With Pentax-airway Scope and Fiberoptic Bronchoscope Alone
NCT02827110 ·Status: COMPLETED ·Phase: NA
-
Comparison of Conventional Lightwand Intubation Versus Video-laryngoscope Guided Lightwand Intubation in Simulated Cervical Spine-immobilized Patients
NCT03169556 ·Status: COMPLETED ·Phase: NA
-
Comparison of Bed up Head Elevated Intubation Position With Glidescope Assisted Tracheal Intubation
NCT03357679 ·Status: COMPLETED ·Phase: NA
-
Do the Head-elevated Position and the Use of a Videolaryngoscope Facilitate Orotracheal Intubation in a Patient Population Without Predictable Difficulty of Intubation
NCT03987009 ·Status: TERMINATED ·Phase: NA