Consistency of Electrical Cardiometry and Pulmonary Artery Catheter
NCT05587400 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 199
Last updated 2022-10-20
Summary
Currently, the gold standard method to estimate CO in patients with PAH or RV dysfunction is pulmonary artery catheter (PAC), however, the invasiveness and complexity of PAC has limited its usefulness in many clinical scenarios. By measuring the thoracic electrical bioimpedance, electrical cardiometry (EC) technique has been reported to noninvasively estimate cardiac output (CO) and other parameters related to cardiac contractility and fluid status in various cardiovascular disorders. However, in patients with pulmonary arterial hypertension (PAH) and/or right ventricular (RV) dysfunction, few study has been reported. The aim of this study is to evaluate the agreement between CO measured by PAC as the referenced method and CO measured by EC technique in patients with PAH and/or RV dysfunction.
Conditions
- Pulmonary Arterial Hypertension
- Right Ventricular Dysfunction
Interventions
- BEHAVIORAL
-
passive leg raising
transfer a patient from semi-recumbent position to supine position with a 45° leg lifting
- DRUG
-
dobutamine test
infusion dobutamine
- DRUG
-
inhaled nitric oxide
nitric oxide inhalation
Sponsors & Collaborators
-
Shanghai Zhongshan Hospital
lead OTHER
Principal Investigators
-
Guang-wei Hao, PhD · Fudan University
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-07-27
- Primary Completion
- 2024-12-31
- Completion
- 2024-12-31
Countries
- China
Study Locations
More Related Trials
-
CardioQ vs Thermodilution Measurements of Cardiac Output
NCT01744795 ·Status: COMPLETED ·Phase: NA
-
Real-time Continuous Cardiac Output Measurements
NCT04774978 ·Status: UNKNOWN ·Phase: NA
-
Discontinuous Echocardiographic Subcostal Cardiac Output Measurement
NCT07177391 ·Status: RECRUITING
-
Comparison of USCOM Cardiac Output and Continuous Thermodilution Cardiac Output
NCT00804778 ·Status: COMPLETED
-
Enhanced Diagnosis of Ventricular Activation Pattern Using Intracardiac Electrograms
NCT02057588 ·Status: COMPLETED ·Phase: NA
-
Cardiac Output Assessment by Using Saline Contrast Injection
NCT04310904 ·Status: UNKNOWN
-
Influence of Extracorporeal Circulation on the Development of OSA (Obstructive Sleep Apnea)
NCT03743090 ·Status: WITHDRAWN
-
Multi-Modality Echocardiographic Techniques in Pathological Left Ventricular Hypertrophy Adults
NCT05719337 ·Status: UNKNOWN
-
Clinical Evaluation of Cardiac Output Estimation Based on Pulse Wave Transit Time
NCT01877941 ·Status: COMPLETED ·Phase: NA
-
Heart Failure Ventricular Pressure Time Profile
NCT02791074 ·Status: COMPLETED
-
Exercise Oxygen Kinetic and Cardiac Output in Hypertrophic Cardiomyopathy
NCT05754489 ·Status: UNKNOWN
-
Preload Dependency by Impedance Cardiography After Cardiac Surgery
NCT02132871 ·Status: COMPLETED
-
Cardiac Output Monitoring With Estimated Continuous Cardiac Output (esCCO) vs. Transpulmonary Thermodilution (TPTD)
NCT02352324 ·Status: COMPLETED ·Phase: NA
-
Comparison of Cardiac Output With LiDCO Rapid and TEE Against Thermodilution Technique in Cardiac Surgery
NCT02511457 ·Status: COMPLETED
-
Comparative Study to Examine Whether Echocardiography Performed During Cardiac Resynchronization Therapy Device Implantation Can Improve the Response Rate
NCT01014000 ·Status: WITHDRAWN ·Phase: NA
-
The Prognostic Role and Diagnostic Efficacy of Exercise Right Heart Catheterization With a Simultaneous Echocardiography in Patients With Dyspnea on Exertion
NCT05490901 ·Status: RECRUITING
-
Evaluation of Clinical Efficacy and Prognosis in Patients with Hypertrophic Obstructive Cardiomyopathy Through Hemodynamic Modeling Reconstructed by CT
NCT06683872 ·Status: ENROLLING_BY_INVITATION
-
Non-invasive Blood Pressure and Cardiac Output Measurement by Using Applanation Tonometry
NCT02444104 ·Status: UNKNOWN
-
Determination of Diastolic Dysfunction by Single Lead Electrocardiogram
NCT04474639 ·Status: COMPLETED
-
Assessment of Right Ventricular Function in Advanced Heart Failure
NCT03893760 ·Status: COMPLETED
-
Pressure-Volume Loop Assessment in Valvular Heart Disease
NCT07112391 ·Status: RECRUITING
-
Accurate Measurement of Cardiac Output Using the Ultrasound Dilution Technique
NCT00851422 ·Status: COMPLETED
-
Comparative Noninvasive Continuous Cardiac Output by the Clearsight® With Invasive Monitoring by PICCO® in Abdominal Major Surgery
NCT02941952 ·Status: COMPLETED ·Phase: NA
-
Myocardial Stiffness Evaluation in Patients With Heart Failure With Preserved Ejection Fraction
NCT06196086 ·Status: RECRUITING
-
Evaluation of a Non-invasive Cardiac Output Monitoring System.
NCT03178097 ·Status: COMPLETED