Evaluation of Wearable Vest for Lung Monitoring
NCT05531539 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 27
Last updated 2022-09-10
Summary
This was the pilot study of the EU funded research and innovation project WELMO (Wearable Electronics for Effective Lung Monitoring) -Grant agreement number: 825572. The clinical trial involved patients suffering from a variety of respiratory pathological conditions and examined the ease-of-use and efficacy of the WELMO system, comprising a sensors vest for thorax auscultation and recording of Electric Impedance Tomography (EIT) signals and transmitting those on the cloud for review by physicians. The study recruited and briefly monitored 27 patients who underwent brief training and subsequent wearing of the sensors vest for 15-20 minutes, after manual auscultation, spirometry and oximetry. The collected data were transmitted wirelessly to a tablet and then securely to the cloud for review by attending physicians. The usability of the system, the quality of the obtained signals and the validity of the results were evaluated.
Conditions
Interventions
- DEVICE
-
WELMO sensors vest
Wearing of a vest equipped with lung auscultation and EIT sensors for signal acquisition and transmission
Sponsors & Collaborators
-
George Papanicolaou Hospital
collaborator OTHER -
Aristotle University Of Thessaloniki
lead OTHER
Principal Investigators
-
Evangelos Kaimakamis, MD, MSc, PhD · 1st ICU, G. papanikolaou Hospital, Thessaloniki, Greece
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 16 Years
- Max Age
- 80 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-01-10
- Primary Completion
- 2022-07-22
- Completion
- 2022-07-30
Countries
- Greece
Study Locations
More Related Trials
-
Evaluation of Novel Lung Function Parameters and Quantitative Computed Tomography (qCT) in Patients With Pulmonary Disease
NCT02826265 ·Status: UNKNOWN
-
Real Time Early Warning Model and Mobile Medical Assistant System for the Impact of Air Pollution on AECOPD Disease
NCT04960410 ·Status: COMPLETED
-
Localization of Peripheral Pulmonary Lesions: A Pilot Study
NCT03536026 ·Status: WITHDRAWN ·Phase: PHASE1
-
Identification of Multiple Pulmonary Diseases Using Volatile Organic Compounds Biomarkers in Human Exhaled Breath
NCT06528418 ·Status: RECRUITING
-
Validation of an Artificial Intelligence Enabled Diagnostic Support Software (ArtiQ.Spiro) in Primary Care Spirometry Datasets - a Retrospective Analysis
NCT05648227 ·Status: ACTIVE_NOT_RECRUITING
-
AI in PRImary Care Spirometry Pathways for Diagnosis of Lung Disease (APRIL)
NCT05865249 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Exercise Hemodynamics in Patients With Pulmonary Fibrosis
NCT03706820 ·Status: UNKNOWN
-
A Study to Investigate the Association of Real-world Sensor-derived Biometric Data With Clinical Parameters and Patient-reported Outcomes for Monitoring Disease Activity in Patients With COPD
NCT05655832 ·Status: COMPLETED ·Phase: NA
-
European Non-interventional Study in Chronic Obstructive Pulmonary Disease (COPD) Patients
NCT00722267 ·Status: COMPLETED
-
Normal Control Cohort Sample Bank
NCT00388765 ·Status: COMPLETED
-
Research on the Characteristics of Chronic Airway Diseases (asthma, COPD)
NCT06685315 ·Status: NOT_YET_RECRUITING
-
Blood Eosinophil Measurements in Patients With Chronic Obstructive Pulmonary Disease
NCT03853642 ·Status: COMPLETED
-
Effect of AIRVO Heated Humidification in Bronchiectasis
NCT04102774 ·Status: COMPLETED ·Phase: NA
-
The JOIN Project: The Air in Diagnosis and Prevention of Asthma and Allergy
NCT02802891 ·Status: COMPLETED
-
A Study in People With Pulmonary Fibrosis to Monitor Cough With a Wearable Device
NCT05670587 ·Status: COMPLETED ·Phase: NA
-
Monitoring of Lung Sounds of Patients With Pneumonia
NCT01818089 ·Status: COMPLETED
-
Post Market Study to Collect Data for Software Recognizing the Anatomical Structures During Bronchoscopy.
NCT04770675 ·Status: COMPLETED
-
Differentiation of Asthma/COPD Exacerbation and Stable State Using Automated Lung Sound Analysis With LungPass Device
NCT05145894 ·Status: UNKNOWN
-
Collection of Blood for Gene Expression Study in Individuals With Chronic Lung Diseases
NCT00320151 ·Status: COMPLETED
-
Air Quality Feedback to Reduce Second-hand Smoke (SHS) Exposure in the Home
NCT03151421 ·Status: COMPLETED ·Phase: NA
-
Controls for Respiratory Diseases
NCT03120481 ·Status: RECRUITING
-
Evaluation of Novel Lung Function Parameters in Patients With Bronchial Asthma
NCT03820427 ·Status: COMPLETED
-
Evaluating Asthma Exacerbation-induced Changes in Lung Function With a Home-based Spirometer
NCT03705325 ·Status: COMPLETED ·Phase: NA
-
Study for Assessing the Prevalence of Airflow Limitation in Outpatients With History of Smoking Attending Cardiology Clinics
NCT07315958 ·Status: RECRUITING
-
Pulmonary Function Test Study - Automated Interpretation
NCT03264417 ·Status: COMPLETED