Comparison of Outcome and Effectiveness Between Micropulse Diode Laser Cyclophotocoagulation and Cyclocryoablation in Treatment of Refractory Glaucoma

NCT05437614 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 47

Last updated 2022-06-29

No results posted yet for this study

Summary

laucoma having bad prognosis after maximally tolerated medication,glaucoma that fails after filtering operations, neovascular glaucoma, glaucoma following vitrectomy and glaucoma secondary to uveitis etc. is collectively termed as refractory glaucoma. For such glaucoma patients, cyclodestructive procedures are often used to reduce IOP, as well as to relieve ocular and periocular pain. Recently,diode laser transscleral cyclophotocoagulation has proved to be an effective method for the treatment of refractory glaucoma and it has become a standard treatment for refractory glaucoma.(Yu, Q., Liang, Y., Ji, F. and Yuan, Z.,et al 2020. ) In previous articles, little is known about the long-term outcomes of micropulse diode laser cyclophotocoagulation and cyclocryotherapy. Discrepancies in the results of several large observational analyses have introduced further ambiguity on the role of micropulse diode laser cyclophotocoagulation and cyclocryotherapy.The mechanism of transcleral cyclophotocoagulation IOP lowering in refractory glaucoma is not well understood. In this study, we perform cyclocryoablation and micropulse diode laser cyclophotocoagulation in patients with refractory glaucoma and report the outcomes / mechanism of IOP control using this new surgical paradigm. The objective of our project is to assess the end result and outcome of the role of micropulse diode laser cyclophotocoagulation and cyclocryotherapy.We aim to evaluate the comparison between micropulse diode laser cyclophotocoagulation and cyclocryotherapy.

Only those subjects will be recruited who provide written informed consent. Patients are diagnosed on bases of tonometry, gonioscopy, ophthalmoscopy, perimetry. Patients' age, gender, type of glaucoma, number of diode laser treatment sessions, postoperative complications, number of hypotensive medications required to control IOP, and best corrected visual acuity (BCVA) will be evaluated. The criteria for success will be defined as postoperative IOP \<21 mmHg or \>20% decrease in IOP with or without additional medical treatment.

Conditions

  • Treatment of Refractory Glaucoma

Interventions

PROCEDURE

Micropulse diode laser cyclophotocoagulation in treatment of refractory Glaucoma

Treatment of refractory Glaucoma by Micropulse diode laser cyclophotocoagulation

PROCEDURE

Cyclocryoablation in treatment of refractory Glaucoma

Treatment of refractory Glaucoma by cyclocryoablation

Sponsors & Collaborators

  • University of Health Sciences Lahore

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2022-03-01
Primary Completion
2022-09-01
Completion
2023-03-01

Countries

  • Pakistan

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT05437614 on ClinicalTrials.gov