Micropulse Laser Trabeculoplasty as Adjunctive Treatment in Patients With Pseudoexfoliation Glaucoma

NCT03483402 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 27

Last updated 2018-04-04

No results posted yet for this study

Summary

This study aims to evaluate the effect of a single session of micropulse laser trabeculoplasty (MLT) on cornea in eyes with primary open glaucoma (POAG) and pseudoexfoliation glaucoma (PEXG).

Conditions

  • Pseudoexfoliation Glaucoma
  • Primary Open-angle Glaucoma

Interventions

PROCEDURE

Micropulse laser trabeculoplasty

Micropulse laser trabeculoplasty is performed using the Iridex IQ 532 laser system (Iridex Corporation, 1212 Terra Bella Avenue, Mountain View, CA, USA) and 532 nm (green) wavelength MLT is applied with confluent applications to pigmented trabecular meshwork over 360 degrees using a 300 µm spot size, 300 ms duration, 1000 mW power and 15% duty cycle.

Sponsors & Collaborators

  • University Hospital of Patras

    lead OTHER

Principal Investigators

  • Constantine D Georgakopoulos, MD, PhD · University of Patras, Medical School

Study Design

Allocation
NA
Purpose
TREATMENT
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2016-12-31
Primary Completion
2018-03-30
Completion
2018-04-02

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.