Sonomyographic Upper Limb Prosthetics: A New Paradigm
NCT05376332 · Status: ENROLLING_BY_INVITATION · Phase: NA · Type: INTERVENTIONAL · Enrollment: 16
Last updated 2026-02-03
Summary
The vast majority of all trauma-related amputations in the United States involve the upper limbs. Approximately half of those individuals who receive a upper extremity myoelectric prosthesis eventually abandon use of the system, primarily because of their limited functionality. Thus, there continues to be a need for a significant improvement in prosthetic control strategies.
The objective of this bioengineering research program is to develop and clinically evaluate a prototype prosthetic control system that uses imaging to sense residual muscle activity, rather than electromyography. This novel approach can better distinguish between different functional compartments in the forearm muscles, and provide robust control signals that are proportional to muscle activity. This improved sensing strategy has the potential to significantly improve functionality of upper extremity prostheses, and provide dexterous intuitive control that is a significant improvement over current state of the art noninvasive control methods. This interdisciplinary project brings together investigators at George Mason University, commercial partners at Infinite Biomedical Technologies as well as clinicians at MedStar National Rehabilitation Hospital.
The investigators will optimize and implement algorithms for real-time classification and control with multiple degrees of freedom (DOF) using a miniaturized ultrasound system incorporated into a prosthetic socket. The investigators will then compare control performance between and sonomyography and myoelectric control (both direct control and pattern recognition) using a virtual environment as well as for performance of tasks related to activities of daily living. The investigators have two specific aims.
Specific Aim 1: Compare between sonomyography and myoelectric direct control Specific Aim 2: Compare between sonomyography and pattern recognition with velocity control The successful completion of this project will lead to the first in human evaluation of an integrated prototype that uses low-power portable imaging sensors and real-time image analysis to sense residual muscle activity for prosthetic control. In the long term, the investigators anticipate that the improvements in functionality and intuitiveness of control will increase acceptance by amputees.
Conditions
- Amputation
- Prosthesis User
Interventions
- DEVICE
-
Sonomyographic Prosthesis
The sonomyographic system will include a custom-fitted test socket incorporating ultrasound transducers and controlling a TASKA prosthetic hand. All socket fittings will be performed by a board-certified prosthetist as part of this study.
- DEVICE
-
Myoelectric direct control prosthesis
The direct control system will include a custom-fitted test socket incorporating dual-site electrodes and controlling a TASKA prosthetic hand. All socket fittings will be performed by a board-certified prosthetist as part of this study.
- DEVICE
-
Myoelectric pattern recognition prosthesis
The pattern recognition system will include the subject's clinically-prescribed socket and commercially-available pattern recognition technology (IBT Sense). The pattern recognition system will not be fitted as part of this study, as subjects will already be trained users prior to enrolling in the study.
Sponsors & Collaborators
-
Infinite Biomedical Technologies
collaborator INDUSTRY -
National Institute for Biomedical Imaging and Bioengineering (NIBIB)
collaborator NIH -
George Mason University
lead OTHER
Principal Investigators
-
Siddhartha Sikdar, PhD · George Mason University
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- CROSSOVER
Eligibility
- Min Age
- 18 Years
- Max Age
- 65 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2023-11-02
- Primary Completion
- 2026-07-31
- Completion
- 2026-07-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
A Multi-Centre Study in Patients Undergoing Total Hip Arthroplasty With the Smith+Nephew CATALYSTEM™ Primary Hip System
NCT06564636 ·Status: ACTIVE_NOT_RECRUITING
-
C-Leg 3 and C-Leg 4 Study in Transfemoral Amputees
NCT02765035 ·Status: COMPLETED ·Phase: NA
-
Prospective Clinical Follow-up of the Echo Bi-Metric Microplasty Stem for Total Hip Arthroplasty
NCT04326010 ·Status: TERMINATED
-
An Integrated Model of Intelligent Medical Service for Total Joint Replacement
NCT03788798 ·Status: COMPLETED ·Phase: NA
-
An Algorithm Creation by Automated Segmentation by MRI for Bone and Muscles of Shoulder
NCT05376813 ·Status: WITHDRAWN ·Phase: NA
-
THA Kinematics and Sound for Subjects for Normal, Diseased and Implanted Hips
NCT02682602 ·Status: COMPLETED
-
Evaluation of a Neural-Controlled Powered Prosthesis Across Diverse Real-World Tasks
NCT07204912 ·Status: RECRUITING ·Phase: NA
-
Acetabular Shell Positioning Using Patient Specific Instruments
NCT01791738 ·Status: COMPLETED ·Phase: PHASE1
-
An Intelligent Instrument for Improved Leg Length and Hip Offset Accuracy in Total Hip Arthroplasty
NCT02095093 ·Status: UNKNOWN ·Phase: NA
-
Uncemented Compared to Cemented Femoral Stems in Total Hip Arthroplasty
NCT02247791 ·Status: UNKNOWN ·Phase: NA
-
Robotic Assisted TKA
NCT06062615 ·Status: COMPLETED ·Phase: NA
-
A Short Metaphyseal Fitting Total Hip Arthroplasty in Young and Elderly Patients
NCT01345097 ·Status: COMPLETED ·Phase: PHASE4
-
Femoral Remodeling Following Total Hip Arthroplasty With OMNI Apex Modular™ and OMNI Apex ARC™ Stem Compared to Competitive Designs
NCT01359540 ·Status: COMPLETED
-
Outcomes of Robotic Total Hip Arthroplasty
NCT01672320 ·Status: WITHDRAWN
-
Effects of Microprocessor-controlled Knee Joints on Community Outcomes
NCT04112901 ·Status: UNKNOWN
-
Sagittal Knee Kinematics of Transtibial Amputee with Running Blade
NCT06586762 ·Status: COMPLETED
-
A Comparison of Patients Receiving a Total Knee Replacement With Robotic Assistance or With Conventional Instrumentation
NCT04976972 ·Status: WITHDRAWN ·Phase: NA
-
Safety and Performance Assessment of the SYMBOL Range of Medical Devices in Patients Underlying Total Hip Arthroplasty
NCT05227924 ·Status: RECRUITING
-
Study of the Clinical and Radiographic Results of a Fixed Polyethylene Posteriorly Stabilized Cemented Total Knee Prosthesis With a Minimum Follow-up of 1 Year.
NCT07313449 ·Status: RECRUITING
-
Retrospective Observational Cohort Study of SYMBOL CUP DM 1
NCT04209374 ·Status: COMPLETED
-
A Safety Follow Up Study in Australian Subjects Implanted With the SMF Short Modular Femoral Stem Hip System
NCT03646513 ·Status: TERMINATED
-
Multicenter Study for Robotic Arm-assisted THA 4.0 System: Hip Spine Relationship
NCT04646096 ·Status: COMPLETED ·Phase: NA
-
A Multi-centre Study to Assess the Long-term Performance of the Summit™ Hip in Primary Total Hip Replacement
NCT00208390 ·Status: TERMINATED ·Phase: PHASE4
-
Southern Bone & Joint Study - Brimless Sockets
NCT01416129 ·Status: COMPLETED ·Phase: PHASE3
-
Ultra-Short Anatomic and Conventional Cementless Stems Cementless Stems in Patients Younger Than Fifty-Five Years Old
NCT02338596 ·Status: COMPLETED ·Phase: PHASE4