Acetabular Shell Positioning Using Patient Specific Instruments
NCT01791738 · Status: COMPLETED · Phase: PHASE1 · Type: INTERVENTIONAL · Enrollment: 36
Last updated 2015-07-10
Summary
The proposed study is a double-blinded randomized controlled trial comparing patient specific instruments with solely standardized instruments and pre-operative planning used for the placement of the acetabular cup prosthesis used in total hip arthroplasty.
The investigators will enroll 36 patients who have consented to total hip arthroplasty for treatment of hip pathology. This treatment is a standard of care. Patients will receive standard of care pre- and post-operative care and placement of standard of care implants all of which are commercially available and FDA approved for general use for the clinical indications used in these patients. All patients will receive a pre-operative CT scan for surgical planning and comparison with post-operative CT scan. The difference in intervention between the groups will be the creation and use of patient specific instruments from the pre-operative planning session. These instruments will be used for placement of an indexing peripheral guide wire to direct acetabular preparation and placement of the shell assisting standard surgical instruments. Print-offs from the pre-operative plan will also be used in the treatment group.
The post-operative scan will be performed within two weeks of the surgery for both the treatment and control groups. The investigators will analyze the difference in acetabular shell placement (acetabular version and abduction angle) from the pre-operatively planned CT scan. These differences will be compared between the control and experimental groups.
Conditions
- Osteoarthritis, Hip
- Rheumatoid Arthritis
- Avascular Necrosis
Interventions
- PROCEDURE
-
Acetabular positioning system
Pre-operative planning through 3D software with design and fabrication of patient specific instruments for placement of a guide pin to be used to aid in bone preparation for insertion of an acetabular cup in total hip arthroplasty
Sponsors & Collaborators
-
The Cleveland Clinic
lead OTHER
Principal Investigators
-
Wael K Barsoum, MD · The Cleveland Clinic
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 85 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2011-01-31
- Primary Completion
- 2012-04-30
- Completion
- 2012-04-30
Countries
- United States
Study Locations
More Related Trials
-
Evaluation of Cemented and Cementless Fixation of Dual-mobility Hip Prosthesis in Elderly Patients With Osteoarthritis
NCT02404727 ·Status: COMPLETED ·Phase: NA
-
A Study Investigating the Effect of Patient Pelvic Positioning and Method of Acetabular Component Insertion on Acetabular Component Inclination During Total Hip Arthroplasty (THA)
NCT01831401 ·Status: COMPLETED ·Phase: NA
-
Clinical Study Evaluating an Acetabular Cup System After Total Hip Replacement
NCT00306930 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Automated and Manual Component Impaction in Total Hip Arthroplasty
NCT05480813 ·Status: COMPLETED ·Phase: NA
-
Patient-Specific Techniques for Hip Replacement
NCT03975673 ·Status: UNKNOWN ·Phase: NA
-
Defining Optimum Cup Orientation for Hip Replacements Taking Into Account the Individual's Anatomy and Movement Patterns
NCT04633525 ·Status: UNKNOWN ·Phase: NA
-
Signature Acetabular Posterior/Lateral Data Collection
NCT02220478 ·Status: TERMINATED ·Phase: NA
-
The Influence of "Operating Table Position Simulating Radiographs" on Acetabular Cup Angle During Primary Total Hip Replacement
NCT00789048 ·Status: COMPLETED ·Phase: NA
-
Comparison of Muscle Atrophy After Direct Anterior & Posterior Total Hip Arthroplasty
NCT01636375 ·Status: COMPLETED
-
Ceramic-on-Ceramic Total Hip Arthroplasty and Squeaking: Influence of Component Design
NCT01420900 ·Status: COMPLETED ·Phase: NA
-
Study of Total Hip Arthroplasty Using Radlink Surgical Positioning Software
NCT02536573 ·Status: COMPLETED ·Phase: NA
-
Pillow Use During Total Hip Arthroplasty
NCT03825029 ·Status: UNKNOWN ·Phase: NA
-
A Single Centre Study to Assess the Long-term Performance of the Pinnacle™ Cup With a Ceramic-on-ceramic Bearing in Primary Total Hip Replacement
NCT00872222 ·Status: TERMINATED ·Phase: PHASE4
-
A Multicenter, Post-Market Clinical Follow-up Study of Subjects With the REDAPT™ System Monolithic Sleeveless/Sleeved Stem and/or Fully Porous Acetabular Shell With XLPE Liner and/or Modular Shell Components Previously Implanted
NCT03610789 ·Status: ENROLLING_BY_INVITATION
-
Direct Anterior Versus Posterior Total Hip Arthroplasty Surgical Approaches
NCT01807494 ·Status: UNKNOWN ·Phase: NA
-
Immediate Post-THA Functional Assessment
NCT04928924 ·Status: UNKNOWN
-
Safety and Effectiveness of the HIT Reverse HRS
NCT05357378 ·Status: RECRUITING ·Phase: NA
-
Survivorship and Patient Outcomes of Primary Total Hip Arthroplasty With the Ovation Hip System
NCT03986918 ·Status: UNKNOWN
-
Survivorship, Radiographic, and Functional Outcomes of the Multihole Revision Acetabular Cup
NCT03031964 ·Status: TERMINATED
-
Pelvic Alignment Level (PAL) Instrument Evaluation
NCT01312428 ·Status: TERMINATED ·Phase: NA
-
Benefit of Orthopedic Navigation in the ARThroplasty of the Hip
NCT01496300 ·Status: COMPLETED ·Phase: PHASE4
-
Healthy Hip Study: Conservative Management for Pre-arthritic Hip Disorders
NCT04069507 ·Status: COMPLETED
-
A Multi-centre, Prospective Surveillance to Assess Mid-term Performance of the Mpact Cup
NCT02196818 ·Status: TERMINATED
-
Gait Initiation and Transition From Double to Single Support in Patients With Unilateral Primary Coxarthrosis
NCT06258369 ·Status: RECRUITING ·Phase: NA
-
Percutaneous Assisted Approach for Total Hip Replacement and it's Effect on Functional Rehabilitation.
NCT02032017 ·Status: UNKNOWN ·Phase: NA