An Intelligent Instrument for Improved Leg Length and Hip Offset Accuracy in Total Hip Arthroplasty
NCT02095093 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 128
Last updated 2014-03-24
Summary
Leg length discrepancies following total hip arthroplasty have been associated with nerve palsies, gait abnormalities, and lower back pain. Leg length discrepancies are related to poorer functional outcomes and patient dissatisfaction. Failure to restore femoral offset following total hip arthroplasty has been linked to decreased range of motion and abductor muscle strength, impingement, limping, higher dislocation rates, increased polyethylene wear, and loosening of implants. Computer navigation has shown to improve the accuracy of leg length and hip offset during total hip arthroplasty. The investigators research objective is to prove the accuracy of the Intellijoint HIP™ system for determining leg length and hip offset. The investigators hypothesis was that Intellijoint HIP™, an imageless intraoperative intelligent instrument, could improve the accuracy of leg length and hip offset during primary total hip arthroplasty. The investigators plan to study this hypothesis in humans by comparing the leg length and hip offset discrepancies produced with Intellijoint HIP™ to the standard at the investigators institution, which is a pin and outrigger system.
Conditions
- Hip Osteoarthritis
- Leg Length Discrepancy
- Dislocation
Interventions
- DEVICE
-
Intellijoint HIP
Intellijoint HIP is an intra-operative, imageless intelligent instrument used to provide real-time information to surgeons about leg length and hip offset changes during total hip replacement surgery.
- DEVICE
-
Outrigger
The outrigger is a pin and caliper device that is used to assess leg length and offset during total hip arthroplasty. It is the current standard of care at Mount Sinai Hospital.
Sponsors & Collaborators
-
Mount Sinai Hospital, Canada
lead OTHER
Principal Investigators
-
Paul Kuzyk, MD · Mount Sinai Hospital, Division of Orthopedic Surgery
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2014-03-31
- Primary Completion
- 2015-12-31
Countries
- Canada
More Related Trials
-
Adaptation of Locomotor Activity in Patients Suffering From Hip OA - Analysis of This Adaptation as a Prognostic Criterion for Future Disease Progression
NCT01907503 ·Status: UNKNOWN ·Phase: NA
-
Using a Smart Implantable Device to Compare Early Recovery in Two Different Knee Arthroplasty Approaches
NCT07348835 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Direct Anterior Versus Posterior Total Hip Arthroplasty Surgical Approaches
NCT01807494 ·Status: UNKNOWN ·Phase: NA
-
Gait Analysis of Anterior Versus Posterior Approach in Performance of Total Hip Arthroplasty
NCT00951951 ·Status: COMPLETED ·Phase: NA
-
A Randomized Study of Approaches in Total Hip Arthroplasty
NCT01613508 ·Status: COMPLETED ·Phase: NA
-
RCT Comparing the DEXA Results of the HA-Omnifit Versus the Symax Uncemented Hip Stem
NCT01695213 ·Status: COMPLETED ·Phase: PHASE4
-
THA Kinematics and Sound for Subjects for Normal, Diseased and Implanted Hips
NCT02682602 ·Status: COMPLETED
-
Kinematic Alignment in Total Knee Arthroplasty - a Double-blind Randomised Controlled Trial Between Robotic and Caliper-based Techniques
NCT06709703 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Fit-Joints: Getting Fit for Hip or Knee Replacement
NCT02885337 ·Status: COMPLETED ·Phase: NA
-
Shoe Lifts for Leg Length Inequality in Adults With Knee or Hip Symptoms
NCT01894100 ·Status: COMPLETED ·Phase: NA
-
Observational Study Evaluating Outcomes of Hip Arthroplasty Using Tornier Dual Mobility Acetabular Cup
NCT02062450 ·Status: COMPLETED
-
Comparison Between Automated and Manual Component Impaction in Total Hip Arthroplasty
NCT05480813 ·Status: COMPLETED ·Phase: NA
-
Changes in Postural Stability Following THA for OA
NCT06088160 ·Status: RECRUITING
-
Evaluation of Proprioception in Patients With Total Hip Replacement
NCT05763368 ·Status: WITHDRAWN ·Phase: NA
-
Assessment With Gait Analysis of Robotic Total Knee Arthroplasty Using Inverse Kinematic Alignment
NCT04912973 ·Status: UNKNOWN ·Phase: NA
-
Evaluate the Effect of Osteo Introducer System in Total Hip Arthroplasty
NCT03113591 ·Status: COMPLETED ·Phase: NA
-
The Influence of Leg Length Discrepancy After Total Hip Arthroplasty on Function and Quality of Life
NCT02275494 ·Status: COMPLETED
-
Anatomical Femoral Stem in Total Hip Arthroplasty
NCT04243980 ·Status: UNKNOWN
-
Safety and Effectiveness of the HIT Reverse HRS
NCT05357378 ·Status: RECRUITING ·Phase: NA
-
Dual Mobility in "High Risk" Patients
NCT04092634 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE4
-
Cup Position in THA With Standard Instruments
NCT03189303 ·Status: COMPLETED
-
Anterior Referencing Versus Posterior Referencing in Minimally Invasive Total Knee Arthroplasty
NCT01135030 ·Status: COMPLETED ·Phase: NA
-
Pillow Use During Total Hip Arthroplasty
NCT03825029 ·Status: UNKNOWN ·Phase: NA
-
Prospective Randomised Study of a New an Uncemented Stem.
NCT04599582 ·Status: COMPLETED ·Phase: NA
-
Function, Pain, and Alignment Following Knee Replacement for the Treatment of Osteoarthritis
NCT05490186 ·Status: TERMINATED ·Phase: NA