Evaluating the Clinical Performance and Usability of Novel Malaria RDTs in Brazil

NCT05317117 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 1030

Last updated 2022-09-27

No results posted yet for this study

Summary

Prospective cross-sectional diagnostic accuracy study with 1,000 patient participants and 30 lay provider/health care worker participants. The patient participant population will be recruited at clinics. At the point of care, study staff will collect capillary blood samples and conduct malaria microscopy (both the standard of care and study specific research-grade microscopy) and two index tests: the NxTek™ Malaria P.f plus Rapid Diagnostic Test (RDT) and the NxTek™ Malaria P.f/P.v RDT. Venous blood will be collected and transferred to the laboratory where the reference PCR assay and three comparator RDTs will be run. The index RDTs will also be repeated in the laboratory. All clinical management of study participants will follow the standard of care for malaria diagnosis in Brazil and will be based on the standard microscopy result. Confirmatory testing may also be conducted, such as typing and sequencing of Plasmodium genes and antigens of interest, including but not limited to HRP2, HRP3, and pLDH as well as the human inflammatory response marker CRP.

The lay provider/health worker participants will include intended users of the index tests. They will be surveyed to assess index test usability through a questionnaire to assess label and packaging comprehension as well as results interpretation.

Conditions

Interventions

DIAGNOSTIC_TEST

NxTek™ Malaria P.f plus Rapid Diagnostic Test (RDT) and NxTek™ Malaria P.f/P.v RDT

The NxTek (TM) Malaria Pf Plus, developed by Abbott, is a sensitive rapid chromatographic immunoassay for the qualitative detection of histidine-rich protein 2 (HRP2) and pLDH on a single test line of Pf malaria in human whole blood. This test is a lateral flow test for in vitro professional diagnostic use and intended as an aid to early diagnosis of Malaria infection in-patients with clinical symptoms. The NxTek (TM) Malaria Pf/Pv Plus, developed by Abbott, is a sensitive rapid chromatographic immunoassay for the qualitative detection of histidine-rich protein 2 (HRP2) and Plasmodium lactate dehydrogenase (pLDH) of Plasmodium falciparum (Pf) on one test line and of pLDH of Plasmodium vivax (Pv) malaria on a second test line in human whole blood. This test is a lateral flow test for in vitro professional diagnostic use and intended as an aid to early diagnosis of Malaria infection in-patients with clinical symptoms.

Sponsors & Collaborators

  • Centro de Pesquisa em Medicina Tropical de Rondonia

    collaborator OTHER_GOV
  • PATH

    lead OTHER

Principal Investigators

  • Gonzalo Domingo, PhD · PATH

Study Design

Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Model
SINGLE_GROUP

Eligibility

Min Age
2 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2022-07-04
Primary Completion
2022-12-01
Completion
2022-12-31

Countries

  • Brazil