Validation and Feasibility in Clinical Practice and Concordance of an Automated System Coupling an RGB-D Camera and a Software Based on Artificial Intelligence for the Measurement of Shoulder Range of Motion for Patients Operated on a Total Reversed Shoulder Prosthesis.
NCT05292157 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 30
Last updated 2025-03-06
Summary
The functional evaluation of the shoulder, which is the most mobile joint in the human body, is a complex clinical examination to perform. The mobility of the shoulder is based on a three-dimensional mobility cone, which is difficult to represent and measure. However, an accurate and reliable measurement of the shoulder's articular amplitude is fundamental for its functional evaluation. Indeed, these measurements contribute to determine the global management strategy of the patient and the follow-up of its evolution.
The conventional method of measuring shoulder joint amplitudes involves the use of a goniometer. Nevertheless, visual estimation is the most used in consultation but is limited by its very examiner-dependent character.
Technological advances have allowed the development and deployment of additional tools in the clinical setting, with the goal of simplifying, reducing measurement bias, and standardizing joint range of motion (ROM) measurement techniques.
Our team has recently published a study to validate the use of a joint ROM measurement system, coupling a RGB-D (Red Green Blue - Depth) sensor and an artificial intelligence (AI) algorithm, on volunteer subjects with no shoulder history. The RGB-D camera is a technological tool in high development and low cost. It consists of two sensors, an infrared projector and an RGB module. The camera simultaneously provides a two-dimensional (2D) image and its environment by creating a color flow using infrared technology combined with a depth map characterizing the distance of objects seen in the image. The AI algorithm then automatically detects a 2D skeleton that identifies the main joints of the upper limb (shoulder, elbow, wrist) and the trunk axis. Then, the angle of interest is measured and each mobility is automatically measured in 3D by the algorithm.
The main objective of the study is to validate and demonstrate the feasibility in clinical practice and the concordance of an automated RGB-D + AI system for the measurement of shoulder joint ROMs of patients having undergone reverse total shoulder replacement surgery. These measurements will be compared with the visual method and the goniometer, that are measurements made in normal care routine. The ROM measures obtained by means of the RGB-D + AI system will be compared to those obtained in clinical practice during the annual follow-up visit in normal care routine. The main evaluation criterion is the measurement of joint amplitude measured in degrees \[°\]. The ROMs that will be measured are those normally assessed in clinical practice: abduction-adduction, flexion-extension and external-internal rotation elbow to body or at 90°.
This study aims also at observing and comparing the postoperative joint ROM measurements estimated in the preoperative planning phase by the Blue-Print software with the actual postoperative ROM measured with the RGB-D + AI system.
The study is observational. The processing of the collected data does not foresee any intervention on the patient or modification of the surgeon's choice concerning the management of the patient. It is indeed a RNIPH (Recherche non impliquant la personne humaine).
Conditions
- Arthroplasty Complications
Interventions
- PROCEDURE
-
shoulder arthroplasty
range of motion (in degrees) measured in annual postoperative follow-up
Sponsors & Collaborators
-
Centre Hospitalier Universitaire de Nice
lead OTHER
Eligibility
- Min Age
- 18 Years
- Max Age
- 90 Years
- Sex
- MALE
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-01-01
- Primary Completion
- 2022-05-01
- Completion
- 2022-12-01
Countries
- France
Study Locations
More Related Trials
-
Dynamic ROM Via Gait Analysis and 3D Fluoroscopy in THA With Different Head Diameters
NCT02047292 ·Status: COMPLETED ·Phase: NA
-
Evaluation of a New Navigation System in Computer-assisted Total Knee Arthroplasty
NCT05435690 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Intra-Operative Evaluation of the Glenoid Implant Position With Structured Light
NCT05148104 ·Status: UNKNOWN
-
Active Versus Passive Motion Device Following Knee Replacement Surgery
NCT02339831 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Anatomic Shoulder Arthroplasty, Hemiarthroplasty, and Reverse Shoulder Arthroplasty.
NCT07060469 ·Status: NOT_YET_RECRUITING
-
Design of Patient Specific Guides (PSG) for Reverse Shoulder Arthroplasty
NCT06611059 ·Status: COMPLETED
-
Robotic Assisted Rehabilitation for Balance and Gait in Orthopedic Patients.
NCT05459584 ·Status: COMPLETED ·Phase: NA
-
Prospective Low Dose CT for Total Shoulder Arthroplasty/Reverse Shoulder Arthroplasty
NCT05350319 ·Status: COMPLETED
-
Reverse Shoulder Replacement: Age 60 or Younger Outcomes
NCT03148184 ·Status: COMPLETED
-
Prosthesis Loosening Imaging With Dual Energy and Tomosynthesis
NCT02874196 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Correlations Between Different Walk Tests in Patients With Transfemoral Amputees
NCT02766387 ·Status: UNKNOWN ·Phase: NA
-
ROM Outcomes in Patients Undergoing a Primary TKA
NCT04217486 ·Status: COMPLETED ·Phase: NA
-
Assessment With Gait Analysis of Robotic Total Knee Arthroplasty Using Inverse Kinematic Alignment
NCT04912973 ·Status: UNKNOWN ·Phase: NA
-
Benefits of Early Proprioceptive Re-education Without Visual Information After Total Knee Arthroplasty
NCT06936267 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Gait After THA: Direct Anterior vs Manual Posterior vs Robotic Posterior
NCT07226973 ·Status: RECRUITING ·Phase: NA
-
Static and Dynamic Balance in Correlation With Quality of Life, in Primary Total Knee Replacement
NCT00256958 ·Status: UNKNOWN ·Phase: PHASE1/PHASE2
-
Evaluation of Robot-assisted Total Knee Arthroplasty with Automatic Balancing
NCT04724915 ·Status: COMPLETED ·Phase: NA
-
Intent Recognition for Prosthesis Control
NCT05537792 ·Status: COMPLETED ·Phase: NA
-
Total Knee Arthroplasty Robot Assisted With MAKO™ Robotic System Compared to the Conventional Total Knee Arthroplasty by Mechanical Ancillary
NCT03566875 ·Status: UNKNOWN ·Phase: NA
-
An Integrated Model of Intelligent Medical Service for Total Joint Replacement
NCT03788798 ·Status: COMPLETED ·Phase: NA
-
Efficacy of Robot-assisted Technique vs Conventional Technique in Preventing Early Micromobilisation After UKA
NCT05204797 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
At Home, Digital Rehabilitation for Patients After Reverse Total Shoulder Arthroplasty
NCT06891378 ·Status: RECRUITING ·Phase: NA
-
Multicenter Study for Robotic Arm-assisted THA 4.0 System: Hip Spine Relationship
NCT04646096 ·Status: COMPLETED ·Phase: NA
-
Measuring Postoperative Mobility, Gait Symmetry and Feedback Following TJA
NCT03673293 ·Status: COMPLETED
-
Long Term Follow-up After Primary or Revision Shoulder Arthroplasty With a Patient- Specific Glenius Implant
NCT03806881 ·Status: ENROLLING_BY_INVITATION