Effect of Shape and Surface Treatment of the Transmucosal Abutments on Peri-implant Health.

NCT05284461 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 10

Last updated 2022-03-17

No results posted yet for this study

Summary

The sample was comprised by 10 patients in which 40 dental implants are placed in an atrophic maxilla. All the implants were connected to 4 types of transepithelial abutment: i.e: parallel anodized abutment(n=10); parallel mechanized abutmen(n=10)t, convergent anodized abutment(n=10); and convergent mechanized abutment (n=10) three months after insertion implants were extracted with the surrounding hard and soft tissues for the histological evaluation of the clinical performance.

Conditions

  • Edentulous; Alveolar Process, Atrophy

Interventions

DEVICE

dental implant with transepithelial abutments manufactured by Galimplant Dental System (Spain)

Dental implants with transepithelial abutments with distinct morphology

Sponsors & Collaborators

  • University of Salamanca

    lead OTHER

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
TRIPLE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2020-05-01
Primary Completion
2021-01-01
Completion
2021-09-01

Countries

  • Spain

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.