A Clinical Trial on the Failure Rates of Metallic and Ceramic Orthodontic Brackets

NCT05151991 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 80

Last updated 2024-01-17

No results posted yet for this study

Summary

The aim of this study is to assess if there are significant differences in the failure rate of stainless steel and ceramic brackets. For this study, patients will be enrolled and divided into two groups, according to the type of brackets (stainless steel or ceramic) used for orthodontic treatment. Failure rates will be recorded every month for 12 months and survival analysis will be performed, together with skeletal and space analysis.

Conditions

  • Dental Malocclusion

Interventions

OTHER

Fixed orthodontic treatment with stainless steel brackets

Orthophosphoric acid 37% acid (Gerhò Etchant gel 37%, Gerhò spa, Terlano, Italy) will be applied for 30 s for the etching of the vestibular surfaces of teeth. The, after rinsing and drying, a thin layer of Transbond XT Light Cure Adhesive Primer (3M Unitek, Monrovia, CA, USA) will be applied and then cured for 10 s with a LED unit. At last, Transbond XT Light Cure Adhesive Paste (3M Unitek) will be applied on the base of stainless steel brackets (Queen Series Low Profile Brackets MBT 0.022", Aestetika, Terni, TR, Italy); brackets will be applied on the vestibular surfaces of teeth with a light pressure and the extra paste will be removed. Curing will be performed with the LED unit at 2 mm distant from the enamel-bracket interface for 40 s, 10 s per each surface (mesial, distal, gingival and occlusal). The following sequence of archwires will be adopted for the first six months: 0.012-in Niti, 0.014-in Niti, 0.016-in NiTi, 0.018 SS, 0.020 SS, 0.017X0.025-in NiTi, 0.019X0.025-in SS.

OTHER

Fixed orthodontic treatment with ceramic brackets

Orthophosphoric acid 37% acid (Gerhò Etchant gel 37%, Gerhò spa, Terlano, Italy) will be applied for 30 s for the etching of the vestibular surfaces of teeth. The, after rinsing and drying, a thin layer of Transbond XT Light Cure Adhesive Primer (3M Unitek, Monrovia, CA, USA) will be applied and then cured for 10 s with a LED unit. At last, Transbond XT Light Cure Adhesive Paste (3M Unitek) will be applied on the base of ceramic brackets; brackets (Super Clear Series Brackets MBT 0.022", Aestetika, Terni, TR, Italy) will be applied on the vestibular surfaces of teeth with a light pressure and the extra paste is removed. Curing will be performed with the LED unit at 2 mm distant from the enamel-bracket interface for 40 s, 10 s per each surface (mesial, distal, gingival and occlusal). Then, the following sequence of archwires will be adopted for the first six months: 0.012-in Niti, 0.014-in Niti, 0.016-in NiTi, 0.018 SS, 0.020 SS, 0.017X0.025-in NiTi, 0.019X0.025-in SS

Sponsors & Collaborators

  • University of Pavia

    lead OTHER

Principal Investigators

  • Andrea Scribante, DDS, PhD · University of Pavia

Study Design

Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
DOUBLE
Model
PARALLEL

Eligibility

Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2021-12-09
Primary Completion
2023-05-04
Completion
2023-05-08

Countries

  • Italy

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.