A Clinical Trial on the Failure Rates of Metallic and Ceramic Orthodontic Brackets
NCT05151991 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 80
Last updated 2024-01-17
Summary
The aim of this study is to assess if there are significant differences in the failure rate of stainless steel and ceramic brackets. For this study, patients will be enrolled and divided into two groups, according to the type of brackets (stainless steel or ceramic) used for orthodontic treatment. Failure rates will be recorded every month for 12 months and survival analysis will be performed, together with skeletal and space analysis.
Conditions
- Dental Malocclusion
Interventions
- OTHER
-
Fixed orthodontic treatment with stainless steel brackets
Orthophosphoric acid 37% acid (Gerhò Etchant gel 37%, Gerhò spa, Terlano, Italy) will be applied for 30 s for the etching of the vestibular surfaces of teeth. The, after rinsing and drying, a thin layer of Transbond XT Light Cure Adhesive Primer (3M Unitek, Monrovia, CA, USA) will be applied and then cured for 10 s with a LED unit. At last, Transbond XT Light Cure Adhesive Paste (3M Unitek) will be applied on the base of stainless steel brackets (Queen Series Low Profile Brackets MBT 0.022", Aestetika, Terni, TR, Italy); brackets will be applied on the vestibular surfaces of teeth with a light pressure and the extra paste will be removed. Curing will be performed with the LED unit at 2 mm distant from the enamel-bracket interface for 40 s, 10 s per each surface (mesial, distal, gingival and occlusal). The following sequence of archwires will be adopted for the first six months: 0.012-in Niti, 0.014-in Niti, 0.016-in NiTi, 0.018 SS, 0.020 SS, 0.017X0.025-in NiTi, 0.019X0.025-in SS.
- OTHER
-
Fixed orthodontic treatment with ceramic brackets
Orthophosphoric acid 37% acid (Gerhò Etchant gel 37%, Gerhò spa, Terlano, Italy) will be applied for 30 s for the etching of the vestibular surfaces of teeth. The, after rinsing and drying, a thin layer of Transbond XT Light Cure Adhesive Primer (3M Unitek, Monrovia, CA, USA) will be applied and then cured for 10 s with a LED unit. At last, Transbond XT Light Cure Adhesive Paste (3M Unitek) will be applied on the base of ceramic brackets; brackets (Super Clear Series Brackets MBT 0.022", Aestetika, Terni, TR, Italy) will be applied on the vestibular surfaces of teeth with a light pressure and the extra paste is removed. Curing will be performed with the LED unit at 2 mm distant from the enamel-bracket interface for 40 s, 10 s per each surface (mesial, distal, gingival and occlusal). Then, the following sequence of archwires will be adopted for the first six months: 0.012-in Niti, 0.014-in Niti, 0.016-in NiTi, 0.018 SS, 0.020 SS, 0.017X0.025-in NiTi, 0.019X0.025-in SS
Sponsors & Collaborators
-
University of Pavia
lead OTHER
Principal Investigators
-
Andrea Scribante, DDS, PhD · University of Pavia
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- DIAGNOSTIC
- Masking
- DOUBLE
- Model
- PARALLEL
Eligibility
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-12-09
- Primary Completion
- 2023-05-04
- Completion
- 2023-05-08
Countries
- Italy
Study Locations
More Related Trials
-
Evaluation of Self-ligating Brackets Plus Minor Surgery in Treating Crowded Cases of Malocclusion
NCT03647241 ·Status: COMPLETED ·Phase: NA
-
EXD-959 Orthodontic Brackets and EXD-961 Related Instruments Trial
NCT03606551 ·Status: UNKNOWN
-
Effectiveness of Tubular Coaxial Nickel-titanium and Copper Nickel-titanium Orthodontic Aligning Archwires
NCT05391542 ·Status: COMPLETED ·Phase: NA
-
Comparison of Perforated 3D Printed Versus Conventional Metal Fixed Bonded Retainer
NCT06851897 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
RMGI v Composite for Orthodontic Bonding
NCT01925924 ·Status: COMPLETED ·Phase: NA
-
CAD/CAM Fixed Retainers vs. Conventional Multistranded Fixed Retainers in Orthodontic Patients. Comparison of Stability, Retainer Failure Rate, Adverse Effects, Cost-effectiveness, and Patient Satisfaction. A Randomized Controlled Clinical Trial
NCT04389879 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Microbial and Periodontal Changes Associated With Conventional Versus Self Ligating Brackets
NCT02436525 ·Status: UNKNOWN ·Phase: NA
-
Comparison of Arch Expansion Changes Between Passive Self-ligating and Conventional Brackets
NCT03363620 ·Status: COMPLETED ·Phase: PHASE3
-
Effectiveness of Gold Fixed Retainers Compared to Conventional Stainless Steel Retainers
NCT07280455 ·Status: RECRUITING ·Phase: NA
-
The Role of Matrix Metalloproteinases (MMPs) in Orthodontic Tooth Movement
NCT00154518 ·Status: COMPLETED ·Phase: PHASE1
-
Comparison Between Lingual and Labial Fixed Orthodontic Appliances in the Treatment of Crowding Cases
NCT03850951 ·Status: COMPLETED ·Phase: NA
-
Comparison of Bond Failure with Resin-modified Glass Ionomer Cement and Visible Light-cure Composite Bonding Material in Adult Orthodontic Patients - a Split-Mouth, Randomized Controlled Trial
NCT06602154 ·Status: COMPLETED ·Phase: NA
-
A Comparison Between GUMMETAL and SS Orthodontic Wires in Space Closure
NCT04591080 ·Status: COMPLETED ·Phase: NA
-
Orthodontic Treatment on Oral Microbiota and Salivary Proteins
NCT06824493 ·Status: NOT_YET_RECRUITING
-
Prospective Randomized Controlled Trial for Prevention of Demineralization During Fixed Orthodontic Treatment
NCT04342858 ·Status: UNKNOWN ·Phase: PHASE2
-
Comparison of Precision in Brackets Position in Two Indirect Bonding Materials
NCT05483114 ·Status: UNKNOWN ·Phase: NA
-
Ankylosed Teeth Treatment by Bone Orthodontic Treatment
NCT02337153 ·Status: UNKNOWN
-
Efficacy and Effectiveness of Two Types of Aligners Based on Stratification by Type of Movement
NCT06516185 ·Status: RECRUITING ·Phase: NA
-
Essix Retainer vs Hawley Retainer
NCT01583933 ·Status: UNKNOWN ·Phase: PHASE3
-
Does the Generation to Which the Operator Belongs Influence the Orthodontic Miniscrew Insertion Accuracy in Dynamic Computer-guided Surgery?
NCT06661551 ·Status: COMPLETED ·Phase: NA
-
COMPARISON OF THE PERCEPTION OF PAIN BETWEEN ORTHODONTIC TREATMENT WITH Invisalign ® AND TREATMENT WITH BRACKETS
NCT01855113 ·Status: COMPLETED
-
Effects of the Different Orthodontic Fixed Retainers on Enamel Colour Change
NCT04105829 ·Status: UNKNOWN ·Phase: NA
-
Comparison of the Brackets Bonded With Bulk Fill Composite and Conventional Composite in Patients Undergoing Fixed Orthodontic Treatment
NCT07155343 ·Status: RECRUITING ·Phase: EARLY_PHASE1
-
Effect of Orthodontic Treatment on the Stability of Pre-Orthodontic Recession Coverage
NCT03886051 ·Status: COMPLETED ·Phase: NA
-
Labial Alveolar Bone Thickness and Apical Root Resorption Changes Associated With Self-ligating Versus Conventional Brackets
NCT02816489 ·Status: UNKNOWN ·Phase: NA