US Pivotal Clinical Study of the Adient Absorbable Filter for the Prevention of Pulmonary Embolism
NCT05127915 · Status: ACTIVE_NOT_RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 854
Last updated 2023-08-31
Summary
The objective of the study is to evaluate the safety and efficacy of the Adient absorbable filter for the prevention of pulmonary embolism (PE: blood clot in the lungs). PE claims the lives of over 100,000 Americans each year, more than breast cancer, traffic fatalities and HIV combined.
Pharmaceutical anticoagulation (blood thinners) that reduce blood clot formation represent the standard of care for treating patients at risk for PE. However, for people who are temporarily unable to use anticoagulants, such as those who have suffered major trauma or those who are scheduled for surgical procedures, inferior vena cava (IVC) filters are used to help protect against PE. These blood filters prevent large blood clots that originate in the deep veins of the legs (deep vein thrombosis (DVT)) from reaching your lungs causing a potentially life-threatening PE.
Conventional metal IVC filters have been proven effective at reducing the incidence of PE, however, most require retrieval. If not retrieved within a timely manner (months), they can perforate the IVC, impale nearby organs with their barbed struts, and cause blood clots.
In contrast, the Adient absorbable filter traps blood clots similar to conventional metal IVC filters, but following the 8 week protection period, the filter itself breaks down into carbon dioxide and water. Hence no filter retrieval is required and complications are less likely due to the shortened indwell time. Once blood clots are trapped in the absorbable filter, the body's thrombolytic enzymes dissolve the clots within weeks while the filter itself resorbs in 6 to 8 months. The absorbable filter is braided from absorbable suture that has been proven safe over 4 decades.
The question being addressed with the randomized controlled trial portion is whether the placement of the absorbable filter in addition to current best practice PE prevention (sequential compression machines, compression stockings, and anticoagulants when indicated) significantly reduces the incidence of clinically significant PE in high risk subjects.
The absorbable filter will be indicated for the temporary prevention of PE in patients with transient high risk for venous thromboembolism (DVT and/or PE) with or without venous thromboembolic disease and as an enhancement to pharmaceutical anticoagulation and mechanical prophylaxis.
Conditions
Interventions
- DEVICE
-
Adient absorbable filter + best practice VTE prophylaxis
Adient absorbable filter helps prevent PE during an 8 week protection period then gradually breaks down into carbon dioxide and water within 6 to 8 months. The absorbable filter does not require removal.
- DEVICE
-
best practice VTE prophylaxis
Best practice VTE prophylaxis includes sequential compression machines, compression stockings, and anticoagulants (blood thinners) when indicated.
Sponsors & Collaborators
-
Avania
collaborator INDUSTRY - collaborator INDUSTRY
-
Adient Medical
lead INDUSTRY
Principal Investigators
-
Matthew Johnson, MD · Indiana University School of Medicine
Study Design
- Allocation
- RANDOMIZED
- Purpose
- PREVENTION
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2023-01-27
- Primary Completion
- 2026-05-31
- Completion
- 2026-12-31
- FDA Device
- Yes
Countries
- United States
Study Locations
More Related Trials
-
Optimum Duration of Acoustic Pulse Thrombolysis Procedure in Acute Pulmonary Embolism
NCT02396758 ·Status: COMPLETED ·Phase: PHASE4
-
Comparison of Two Pulmonary Embolism Treatments
NCT05684796 ·Status: COMPLETED ·Phase: NA
-
A Phase II Study to Evaluate the Efficacy of ThromboView® in the Detection of Pulmonary Emboli
NCT00519506 ·Status: COMPLETED ·Phase: PHASE2
-
Ventilation and Perfusion Scan in Pulmonary Embolism Following Catheter Directed Thrombectomy Versus Anticoagulation Alone
NCT05133713 ·Status: UNKNOWN
-
Selective Pulmonary-artery Intervention to Reduce Acute Right-heart tEnsion-II
NCT06576427 ·Status: COMPLETED ·Phase: NA
-
An Observational Study About Adverse Outcomes in Acute Pulmonary Embolism Patients
NCT05481242 ·Status: ACTIVE_NOT_RECRUITING
-
Adrenomedullin in Context With Pulmonary Embolism
NCT04875130 ·Status: COMPLETED
-
Standard vs Ultrasound-assisted Catheter Thrombolysis for Submassive Pulmonary Embolism
NCT03086317 ·Status: COMPLETED ·Phase: NA
-
A Prospective Study for the Treatment of Severe Pulmonary Embolism With Pharmacodynamic Thrombectomy
NCT04318782 ·Status: UNKNOWN ·Phase: NA
-
Safety and Effectiveness of the ATC System in the Treatment of Acute PE
NCT06152341 ·Status: RECRUITING ·Phase: NA
-
CLEANer Aspiration for Pulmonary Embolism
NCT06189313 ·Status: SUSPENDED ·Phase: NA
-
Acute Pulmonary Embolism Treatment With the AlphaVac Multipurpose Mechanical Aspiration System and the AlphaReturn Blood Management System: Evaluation of Safety and Effectiveness
NCT07280247 ·Status: RECRUITING ·Phase: NA
-
Assessing the Prognosis of Pulmonary Embolism Using Clinical and Imaging Biomarkers (Retrospective & Prospective )
NCT00805246 ·Status: COMPLETED
-
Non-Contrast 4DCT to Detect Pulmonary Thromboembolic Events
NCT03183063 ·Status: COMPLETED ·Phase: NA
-
Evaluating the Safety and Efficacy of the AlphaVac Multipurpose Mechanical Aspiration (MMA) F1885 PE for Treatment of Acute Pulmonary Embolism
NCT05318092 ·Status: COMPLETED ·Phase: NA
-
Evaluation of the Magneto eTrieve™ PE Kit for Endovascular Thrombectomy in Subjects With Acute Pulmonary Embolism
NCT05821426 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Thrombolytic and Interventional Treatment of Pulmonary Embolism
NCT03886194 ·Status: UNKNOWN ·Phase: NA
-
Safety and Effectiveness of the Akura Thrombectomy System for Use in the Removal of Emboli From the Pulmonary Arteries in Treating Acute Pulmonary Embolism (PE)
NCT06672510 ·Status: RECRUITING ·Phase: NA
-
The PEERLESS Study
NCT05111613 ·Status: COMPLETED ·Phase: NA
-
SaExten Vena Cava Filter System in Prevention of Pulmonary Embolism
NCT04948502 ·Status: COMPLETED ·Phase: NA
-
Ultrasound-facilitated, Catheter-directed, Thrombolysis in Intermediate-high Risk Pulmonary Embolism
NCT04790370 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE4
-
Detecting Circulating Emboli in Patients with Acute Venous Thromboembolism
NCT02735759 ·Status: WITHDRAWN ·Phase: NA
-
Catheter Directed Therapy in Intermediate Risk Pulmonary Embolism Patients
NCT05612854 ·Status: UNKNOWN ·Phase: EARLY_PHASE1
-
Prognostic Tools in Patients With Acute Pulmonary Thromboembolism.
NCT04237974 ·Status: UNKNOWN
-
Multi-Center Human Alert Trial to Prevent DVT and PE
NCT00409136 ·Status: COMPLETED