Study of the Effectiveness of a Polymer Cerclage System Compared to Cerclages Used in Standard Care (CERCPMCF) )
NCT05087667 · Status: RECRUITING · Phase: NA · Type: INTERVENTIONAL · Enrollment: 202
Last updated 2025-03-20
Summary
The use of cerclage wiring in the management of long bone fractures is common. With the increase in the placement of total hip ans shoulder prostheses, the occurrence of peri-prosthetic hip an shoulder fractures is also increasing, notably due to an older population.
Whether it is for a fracture on a native femur or humerus, or on a periprosthetic hip or shoulder fracture, the use of cerclage wiring is an adjuvant additional but not the main means to ensure stable osteosynthesis, allowing re-loading and early rehabilitation of patients. This method has demonstrated its ability to improve the fixation of this fracture type, associated with osteosynthesis or hip/shoulder prosthesis revision surgery. However, metal cerclage expose to a risk of metallosis which can compromise bone fusion, injury to neighboring soft parts causing pain and also injury to the surgical team when handling them. More recently, non-metallic cerclage have been developed and could overcome certain risks associated with metallic cerclage, while ensuring their bone fixing capacity and therefore bone consolidation. Indeed, non-metallic cerclage could withstand similar or even greater stresses than metallic cables, in particular concerning their resistance to rupture.
The "Sterile Self Locking Polymer Cerclage System" named OrthoLoop is a polymer cerclage which has been developed and could be used in these indications.
Thus, this study (SERRE) aims to investigate the clinical results and sequelae of adjuvant cerclage wires OrthoLoop Cerclage in the management of rehabilitation, per prosthetic or primary femoral or humeral fractures compared with cerclages system used in standard care.
SERRE is a 36 months follow up study in two arms :
* Experimental group: "OrthoLoop cercalge"
* Control group: "cerclages used in standard care" After each surgery, the patient follow-up period is 36 months. with 4 planned consultation visits after surgery at 6-8 weeks, 3, 6 and 36 months, with collection and measurement of the endpoints.
The main objective of this study is to assess the role of "OrthoLoop cerclage" of COUSIN Biotech in comparison with cerclages (metallic for the majority) used in standard care ; in the optimization of the consolidation of primary and periprosthetic femoral or humeral fractures, 6 months after surgery.
Conditions
- Femoral Fracture
Interventions
- DEVICE
-
Implantation of Ortholoop cerclage
implantation of Sterile Self Locking Polymer Cerclage System named OrthoLoop to the patient and follow up for 36 months post-intervention
- DEVICE
-
Implantation of Cerclage used in current practice
implantation of Cerclage used in current practice to patients and follow up for 36 months post-intervention
Sponsors & Collaborators
-
Cousin Biotech
collaborator INDUSTRY -
Quanta Medical
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2022-03-08
- Primary Completion
- 2026-06-30
- Completion
- 2028-12-31
Countries
- France
Study Locations
More Related Trials
-
Study on Outcomes of Proximal Humerus Fractures
NCT07060664 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Operative Versus Nonoperative Treatment of Humeral Shaft Fractures: A Prospective Cohort Comparison Study
NCT01363518 ·Status: COMPLETED
-
Conservative vs Surgical Treatment for Proximal Humerus Fractures in the Elderly
NCT02913378 ·Status: UNKNOWN ·Phase: NA
-
Mini-invasive Preventive Fixation of the Contralateral Femoral Neck in Patients Operated on for a Femoral Neck Fracture
NCT04408053 ·Status: UNKNOWN ·Phase: PHASE3
-
Femoral Neck Locking Plate Vs Multiple Cannulated Cancellous Screws in Treatment of Femoral Neck Fractures in Young Adults: Randomized Controlled Clinical Trial Study
NCT06162637 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Fixation Methods of Basicervical Fractures
NCT04240743 ·Status: COMPLETED ·Phase: NA
-
Surgery of the Pilon Fractures
NCT03367169 ·Status: TERMINATED ·Phase: NA
-
Outcomes of Hemiarthroplasty Versus Cephalo-medullary Fixation to Treat Unstable Intertrochanteric Femoral Fractures
NCT05134805 ·Status: UNKNOWN ·Phase: NA
-
Fixation of Displaced Midshaft Clavicular Fractures in Adults by Intramedullary Elastic Rod
NCT03462901 ·Status: UNKNOWN ·Phase: NA
-
Treatment Of Supracondylar Fractures Closed Reduction And Circular Ring External Fixation Versus Open Reduction and Internal Fixation
NCT02196311 ·Status: WITHDRAWN
-
Two-stage Treatment of Large Bone Defects With Cerament® G and Cerament® V Plus Auto and/or Allograft Using the Masquelet Technique as Salvage Therapy After Bone Resection in Patients With Septic Pseudarthrosis
NCT03970941 ·Status: COMPLETED
-
Influence of Osteoporosis on Clinical Outcomes of Mini-invasive Surgical Treatment of Proximal Humerus Fractures
NCT02750839 ·Status: UNKNOWN
-
VertebrOpLasty Versus Conservative Treatment in Acute Non Osteoporotic Vertebral Fractures
NCT01643395 ·Status: COMPLETED ·Phase: PHASE3
-
Lateral Mini Approach vs Anterior Approach for Plating of Proximal Humerus Fracture
NCT00612391 ·Status: COMPLETED ·Phase: NA
-
Randomised Study Between Intramedullary Locking Nails and Locking Plates for Treatment of Proximal Humerus Fractures
NCT01557413 ·Status: COMPLETED ·Phase: NA
-
Intracapsular Femoral Neck Fractures Fixation With a Dynamic Locking Plate and Screw System, Targon FN
NCT00830687 ·Status: UNKNOWN ·Phase: NA
-
Orthopedic Intelligent Navigation System in the Treatment of Fresh Femoral Neck Fractures
NCT06713018 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Use of a Minimally Invasive Internal Fixation Device for Treatment of Unstable Pelvic Ring Fractures
NCT05871866 ·Status: UNKNOWN ·Phase: NA
-
Operative Treatment of 2-fragment-fractures (AO 11-A3) of the Proximal Humerus in the Elderly: Cement Augmented Locking Plate Philos vs. Proximal Humerus Nail MultiLoc
NCT02609906 ·Status: UNKNOWN ·Phase: NA
-
Percutaneous Versus Open Plate Fixation of Diaphyseal Clavicle Fractures
NCT01405703 ·Status: COMPLETED
-
Plate Fixation of Distal Femur Fractures: A Protocol for a Study of Two Plate Options
NCT00644397 ·Status: COMPLETED
-
Early Percutaneous Vertebroplasty Versus Standard Conservative Treatment in Thoracolumbar Vertebral Fractures
NCT03617094 ·Status: COMPLETED ·Phase: NA
-
Effectiveness of Intensive Rehabilitation on Shoulder Function After Proximal Humerus Fracture
NCT01113411 ·Status: UNKNOWN ·Phase: NA
-
Cemented vs Non-cemented Semiendoprosthesis in the Treatment of Proximal Femoral Fractures
NCT00859378 ·Status: UNKNOWN ·Phase: NA
-
Surgically Treated Displaced Mid-diaphyseal Clavicle Fractures
NCT05867355 ·Status: RECRUITING