Temporary Epicardial Pace Wire With Integrated Sensor for Continuous Postoperative Monitoring of Myocardial Function
NCT04886934 · Status: ENROLLING_BY_INVITATION · Phase: NA · Type: INTERVENTIONAL · Enrollment: 38
Last updated 2024-02-16
Summary
Transesophageal echocardiography is used to monitor cardiac wall motion at various time points during open-heart surgery. After surgery, the measurements are made at various time points by transthoracic echocardiography.
The CS1 system enables continuous, direct measurement of cardiac wall motion. This is achieved through use of temporary pacemaker wires incorporating a motion detector called an accelerometer. Use of TMEs during and after open-heart surgery is part of the normal clinical routine. Continuous monitoring of cardiac wall motion during and after surgery can quickly highlight the need for medical intervention with cardiac drugs and allow very early detection of potentially serious complications leading to abnormal cardiac wall motion.
Cardiac wall motion activity registered by the CS1 system and echocardiography at specific time points during and after surgery will be analyzed to see how well they compare.
Conditions
- Cardiac Disease
- Myocardial Dysfunction
Interventions
- DEVICE
-
CS1 System
Placement of CS1, a temporary bipolar myocardial electrode (TME) with an integrated motion sensor (accelerometer), on the left ventricle and externalization of the associated leads through the chest wall during open-heart surgery. CS1 will remain in place for up to 7 days after surgery and closure of the chest wall.
Sponsors & Collaborators
- collaborator OTHER
-
Cardiaccs AS
lead INDUSTRY
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 19 Years
- Max Age
- 99 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-10-25
- Primary Completion
- 2024-12-31
- Completion
- 2025-03-31
Countries
- Norway
Study Locations
More Related Trials
-
Right Ventricular Echocardiography in caRdiac SurgEry
NCT03301571 ·Status: COMPLETED ·Phase: NA
-
An Intracavitary Electrocardiographic System for Real-time Positioning Peripherally Inserted Central Catheter Tip
NCT02409589 ·Status: COMPLETED ·Phase: NA
-
Cardiac Deformation: Correlation With Conventional Echocardiographic Hemodynamic Variables (An Intraoperative Study)
NCT00874991 ·Status: COMPLETED
-
Impact of Anesthesia, Positive Pressure Ventilation and Modality of Imaging on the Echocardiographic Assessment of the Severity of Aortic Regurgitation
NCT06835946 ·Status: RECRUITING
-
Continuous Monitoring of Right Ventricular Function, Based on the Correlation Between the C-X Segment of the Central Venous Pressure Curve, and the Echocardiographic Evaluation of Right Ventricular Systolic Function
NCT03295669 ·Status: COMPLETED
-
3D Echocardiographic Assessment of Epicardial Pacing After Cardiopulmonary Bypass.
NCT02842762 ·Status: UNKNOWN ·Phase: NA
-
Echocardiographic Findings and 30-days Outcomes for Intraventricular Conduction Delay in Patients Undergoing Elective Surgeries
NCT02718313 ·Status: COMPLETED
-
Comparison of a New Semi-invasive Monitoring System With Transpulmonary Thermodilution in Cardiac Surgery Patients
NCT02312505 ·Status: COMPLETED ·Phase: NA
-
Ventricular Stimulation as Predictor of Hypovolemia After Cardiac Surgery
NCT03926910 ·Status: COMPLETED ·Phase: NA
-
Specke Tracking Echocardiography And Filling Pressures
NCT02854865 ·Status: UNKNOWN
-
Hemodynamic Measurements During Liver Transplantation
NCT00682110 ·Status: COMPLETED
-
Relationship Between the Posterior Atrial Wall and the Esophagus: Esophageal Position and Temperature MEasurement During Atrial Fibrillation Ablation.
NCT04394923 ·Status: COMPLETED ·Phase: NA
-
Cardiac Elastography Measurement : an Intraoperative Cardiac Surgery Study
NCT02051920 ·Status: UNKNOWN
-
FLuid Responsiveness Prediction Using EXtra Systoles
NCT03002129 ·Status: COMPLETED ·Phase: NA
-
Real-time Continuous Cardiac Output Measurements
NCT04774978 ·Status: UNKNOWN ·Phase: NA
-
Continuous Ambulatory ECG Monitoring for Detection of Postoperative Atrial Fibrillation Following Thoracic Surgery
NCT04325269 ·Status: UNKNOWN
-
Multiparametric MRI Assessment of Atrial Heart Disease as a Predictor of Atrial Fibrillation After Myocardial Revascularization Surgery
NCT04657835 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Comparison Endotracheal Cardiac Output Monitor (ECOM) to a Standard Device in Measuring Heart Blood Volume
NCT00883857 ·Status: COMPLETED
-
Electrical Cardioversion As a Predictor in Postoperative Preservation of Sinus Rhythm
NCT06654401 ·Status: RECRUITING ·Phase: NA
-
Enhanced Diagnosis of Ventricular Activation Pattern Using Intracardiac Electrograms
NCT02057588 ·Status: COMPLETED ·Phase: NA
-
Remote Electrocardiographic (ECG) ST-Monitoring (PROSE 3)in Post-op Patients
NCT01423136 ·Status: COMPLETED
-
Impact of Intraventricular Electrical Activation in Resynchronization Therapy
NCT01270646 ·Status: COMPLETED ·Phase: PHASE2
-
Digital Image Correlation in Right Ventricular Evaluation
NCT03115294 ·Status: COMPLETED ·Phase: NA
-
C-MAC Videolaryngoscope for Insertion of a Transesophageal Echocardiography Probe in ICU Patients
NCT04980976 ·Status: COMPLETED ·Phase: NA
-
Uncalibrated Pulse Contour to Assess Fluid Responsiveness in Off Pump Cardiac Surgery
NCT06822361 ·Status: COMPLETED