Annuloplasty Rings and Band Post-Market Clinical Follow-Up Study

NCT04761120 · Status: RECRUITING · Type: OBSERVATIONAL · Enrollment: 550

Last updated 2026-05-18

No results posted yet for this study

Summary

ARB-PMCF is a multicenter, observational study of the safety and performance of Abbott annuloplasty devices used in surgical repair of mitral and tricuspid valve regurgitation. The devices included in this study are the SJM™ Rigid Saddle Ring and SJM Séguin Annuloplasty Ring, indicated for mitral valve repair, and the SJM Tailor™ Annuloplasty Ring and SJM Tailor Annuloplasty Band, indicated for mitral or tricuspid repair. Participants will be enrolled prior to undergoing mitral or tricuspid valve repair surgery including an Abbott annuloplasty implant and will complete annual follow-up visits through five years from implant. The study is being conducted to meet post-market clinical follow-up requirements of the European Union Medical Device Directives.

Conditions

  • Mitral Regurgitation
  • Tricuspid Regurgitation
  • Valvular Heart Disease

Interventions

DEVICE

Abbott SJM Rigid Saddle Ring

The Abbott SJM Rigid Saddle Ring is a rigid, polyester-velour-covered, titanium alloy mitral annuloplasty ring with a saddle shape intended to mimic the shape of a healthy mitral annulus during systole.

DEVICE

Abbott SJM Séguin Ring

The Abbott SJM Séguin Ring is a semi-rigid, polyester-velour-covered, polyethylene mitral annuloplasty ring that varies in thickness and flexibility over its circumference, with the posterior portion of the ring having greater flexibility than the anterior portion.

DEVICE

Abbott SJM Tailor Ring

The Abbott SJM Tailor Ring is a flexible, polyester-velour-covered, silicone annuloplasty ring indicated for use in surgical repair of the mitral or tricuspid valve. The Tailor Ring can be implanted as a full annuloplasty ring, or the surgeon can remove the ring's cut zone with a scalpel and use the partial Tailor Ring as a posterior annuloplasty band.

DEVICE

Abbott SJM Tailor Band

The Abbott SJM Tailor Band is a flexible, polyester-velour-covered, silicone band for posterior annuloplasty indicated for use in surgical repair of mitral or tricuspid valve. The Tailor Band is identical to the Tailor Ring with the cut zone removed, save that the polyester covering is sewn closed at the ends of the band during manufacturing.

Sponsors & Collaborators

  • Abbott Medical Devices

    lead INDUSTRY

Principal Investigators

  • Ryan Palmer · Abbott

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2021-02-01
Primary Completion
2030-11-30
Completion
2031-03-31
FDA Device
Yes

Countries

  • United States
  • Estonia
  • France
  • Germany
  • Italy
  • Netherlands
  • Spain

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04761120 on ClinicalTrials.gov