Assessment of Sustained Systolic-to-diastolic Flexibility of the Mitral Valve Annulus With the Sorin MEMO 3D Mitral Anuloplasty Ring
NCT01987635 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 33
Last updated 2022-12-09
Summary
Mitral valve reconstruction commonly requires the use of an anuloplasty device to assure long-term durability of the repair. Among mitral anuloplasty devices, varying from rigid to complete flexible ring substitutes, the most recent ones are aimed to restore the natural saddle shape of the mitral annulus, in order to decrease the stress tension on both mitral leaflets and chordal attachments. So far, even for flexible ring devices, the sustained flexibility of the device remained unproven, probably by cicatricial fibrotic tissue ingrowth after implantation.
Due to specific structural characteristics based on a nitinolstent with carbofilm-coating, the MEMO 3D ring device of SORIN claims preservation of the ring flexibility during the cardiac cyclus. Consequently, mitral anuloplasty with this device is expected to decrease the stress during the systolo-diastolic movements of the valve, and so, improve the late durability of the repair.
Echocardiography is the first-line technique for mitral valve assessment after surgical repair, for both intra-operative evaluation and serial follow-up of valve function. Recently, three-dimensional echocardiography has been introduced into clinical practice, affording qualitative and quantitative measurement of mitral valve function and size during the cardiac cycle.This method allows to quantify precisely the excursion of the mitral annulus between systole and diastole.
The aim of this study is to analyse the systolo-diastolic movement of the mitral annulus after the use of an anuloplasty with the SORIN MEMO 3D device, after surgical implantation and its sustainability, 1 year after implantation.
This hypothesis is tested in a case-controlled comparison with a standard used rigid ring device.
Therefore, 3-D echocardiography will be performed at the time of surgical repair, and after 1 year, to define the size and surface change of the mitral anuloplasty device during the cardiac cycle.
Based on a sample size calculation, 10 patients in each comparison group will be included, suggesting a study cohort of 20 patients eligible for mitral valve repair.
Conditions
- Mitral Valve Disease
Interventions
- DEVICE
-
MEMO 3D ring
The experimental MEMO 3D ring is placed.
- DEVICE
-
Standard use of rigid ring.
The rigid ring is placed, which is standard procedure.
- PROCEDURE
-
3D Echocardiography
Sponsors & Collaborators
-
LivaNova
collaborator INDUSTRY -
University Hospital, Ghent
lead OTHER
Principal Investigators
-
Guy Vandenplas, MD · University Hospital, Ghent
Study Design
- Allocation
- NON_RANDOMIZED
- Purpose
- TREATMENT
- Masking
- NONE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2014-01-16
- Primary Completion
- 2016-09-13
- Completion
- 2018-09-28
Countries
- Belgium
Study Locations
More Related Trials
-
Prophylactic Tricuspid Valve Annuloplasty in Patients Undergoing Mitral Valve Surgery
NCT01580436 ·Status: UNKNOWN ·Phase: NA
-
Mitral Valve Annulus Assessment, Multimodality Imaging
NCT06797687 ·Status: RECRUITING
-
Repair of Ischemic Mitral Regurgitation: Comparison Between Flexible and Rigid Annuloplasty Rings
NCT00491452 ·Status: COMPLETED
-
Myocardial Characterization of Arrhythmogenic Mitral Valve Prolapse (STAMP: STretch and Myocardial Characterization in Arrhythmogenic Mitral Valve Prolapse)
NCT02879825 ·Status: COMPLETED ·Phase: NA
-
Effectiveness and Durability Long-term Results of Tricuspid Annuloplasty With 3D Shaped Rings.
NCT05836415 ·Status: COMPLETED
-
Is Mitral Annuloplasty an Effective Treatment for Severe Atrial Functional MR?
NCT05836376 ·Status: COMPLETED
-
Normal Values in Stress Echocardiographic Parameters in Patients After Successful Mitral Valve Repair for Organic MR
NCT02371863 ·Status: COMPLETED
-
European Association of Cardiovascular Imaging Multiple and Mixed Valvular Disease Study
NCT06235385 ·Status: RECRUITING
-
Prediction of Reverse Remodeling and Outcome in Patients With Severe Secondary Mitral Valve Regurgitation Undergoing Transcatheter Edge-to-edge Mitral Valve Repair
NCT04913727 ·Status: RECRUITING ·Phase: NA
-
Outcome of MC3 Ring Annuloplasty for Functional Tricuspid Regurgitation
NCT04078867 ·Status: COMPLETED
-
5-Year Follow-Up Safety and Performance Evaluation of the Medtentia Annuloplasty Ring in Adults
NCT04161079 ·Status: COMPLETED
-
Evaluation of the Elasticity of the Mitral Valve
NCT06153563 ·Status: RECRUITING
-
Evaluation of Tricuspid Valve Percutaneous Repair System in the Treatment of Severe Secondary Tricuspid Disorders
NCT04646811 ·Status: COMPLETED ·Phase: NA
-
CG Future® Annuloplasty Ring/Band Clinical Trial
NCT01074671 ·Status: COMPLETED ·Phase: PHASE4
-
EASE MITRAL Expertise-based Assessment Study on Clinical Efficacy of Profile 3D in MITRAL Valve Annuloplasty
NCT01112566 ·Status: COMPLETED
-
STretch and Myocardial Characterization in Arrythmogenic Mitral Valve Prolapse-2
NCT04852731 ·Status: RECRUITING ·Phase: NA
-
Left Chamber Function in Mitral Regurgitation and Predicting Outcome After Replacement and Targeting for Early Surgery
NCT03870516 ·Status: UNKNOWN ·Phase: NA
-
MRI as a Predictor of Outcomes in Patients Undergoing Mitral Valve Surgery
NCT03012178 ·Status: UNKNOWN
-
The Asia-Pacific Mitral & Tricuspid Valve-in-Valve/Valve-in-Ring Registry
NCT07296016 ·Status: NOT_YET_RECRUITING
-
Fate of Moderate Secondary Mitral Regurgitation in Patients Undergoing Aortic Valve Surgery for Severe Aortic Regurgitation
NCT05774808 ·Status: COMPLETED
-
Mosaic Mitral Valve: Long-Term Outcomes in Patients Under 65
NCT06917586 ·Status: RECRUITING
-
Study on Efficacy, Safety and Durability of the UniLine Prosthesis in the Treatment of Aortic and Mitral Valve Disease
NCT05895487 ·Status: RECRUITING
-
Impact of Preoperative Myocardial Fibrosis Related to Mitral Valve Prolapse on Postoperative Left Ventricular Remodeling
NCT05284058 ·Status: COMPLETED ·Phase: NA
-
Cardiac Implantable Electronic Device- Induced Remodelling of Tricuspid Valve and Right Chambers
NCT06914570 ·Status: RECRUITING
-
Natural History of Melody Valve in the Mitral and Tricuspid Position
NCT02505074 ·Status: UNKNOWN