RHA® 4 NLF Cannula

NCT04754646 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 50

Last updated 2023-03-09

Study results available
· View outcomes & findings →

Summary

This is a randomized, controlled, single-blinded, within-subject (split-face), multicenter, prospective study to investigate whether RHA®4 injected in NLFs with a cannula is non-inferior to RHA®4 injected in NLFs with a sharp needle (27G x ½") for the correction of moderate to severe NLFs as determined by the Blinded Live Evaluator (BLE) using the Teoxyne NLF-WSRS (proprietary, validated NLF Wrinkle Severity Rating Scale) at 12 weeks from last treatment.

At Visit 1 (Week 0), RHA®4 injected with cannula will be administered in a random sequence (first or second injection) and side of the face (left or right NLF) and RHA®4 injected with a sharp needle will be administered to the other side. The TI will administer study devices and will be unblinded to treatment allocation. Blinded assessments of effectiveness will be conducted by the BLE (Blinded Live Evaluator).

4 weeks following initial treatment, subjects will attend Visit 2 and receive, if necessary, touch-up treatments (using a needle or cannula as per the subject's initial treatment assignment).

Subjects receiving touch-up treatments at Week 4 (Visit 2) will attend a new Visit 2b (4 weeks following touch-up treatment); subject not receiving touch-up treatment will not attend Visit 2b.

After each injection (initial treatment or touch-up), subjects will receive a safety follow-up call from the study site within 3-day.

Subjects will then attend scheduled in-office study visits at 8 (Visit 3) and 12 weeks (Visit 4) following last treatment (initial treatment or touch-up) where safety and effectiveness assessments will be conducted.

Conditions

  • Wrinkle
  • Nasolabial Fold
  • Aging

Interventions

DEVICE

Split-face injection of RHA® 4 with a cannula into a single NLF.

RHA® 4 is a sterile, biodegradable, biocompatible, viscoelastic, clear, colorless, homogenized gel implant. It consists of cross-linked hyaluronic acid produced by fermentation of Streptococcus equi bacteria, formulated to a concentration of 23 mg/mL and 0.3% w/w lidocaine in a physiologic buffer. Up to 3.0 mL injected per NLF (mid-dermis to deep-dermis). Touch-up treatment provided at 2 weeks (up to 3.0 mL per NLF). The brand of cannula used for injection is up to the discretion of the Treating Investigator (TI), providing the cannula is registered for use by the US FDA.

DEVICE

Split-face injection of RHA® 4 with a needle (TSK 27G x ½") into the contralateral NLF.

RHA® 4 is a sterile, biodegradable, biocompatible, viscoelastic, clear, colorless, homogenized gel implant. It consists of cross-linked hyaluronic acid produced by fermentation of Streptococcus equi bacteria, formulated to a concentration of 23 mg/mL and 0.3% w/w lidocaine in a physiologic buffer. Up to 3.0 mL injected per NLF (mid-dermis to deep-dermis). Touch-up treatment provided at 2 weeks (up to 3.0 mL per NLF).

Sponsors & Collaborators

  • Teoxane SA

    lead INDUSTRY

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Model
PARALLEL

Eligibility

Min Age
22 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2021-03-15
Primary Completion
2021-08-17
Completion
2021-11-29
FDA Device
Yes

Countries

  • United States

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04754646 on ClinicalTrials.gov