RHA®4 for Midface Volume Deficiency
NCT05133739 · Status: COMPLETED · Type: INTERVENTIONAL · Enrollment: 201
Last updated 2025-03-18
Summary
This is a prospective, randomized, controlled, blinded evaluator, multicenter, between subjects clinical study to identify whether RHA4 is non-inferior to a comparator device for treatment of midface volume deficiency 8 weeks after the last treatment (initial or touch-up).
At Screening, the treating investigator (TI) and the Blinded Live Evaluator (BLE) will evaluate independently the subject's midface using the validated 5-grade Teoxane Midface Volume Deficit Scale (TMVDS) for eligibility of the subject for the study. The BLE will establish a pretreatment score for assessment of effectiveness.
If the assessments of the TI and the BLE are the same or differ exactly by 1 point of the scale, the difference will be considered acceptable. The TI and the BLE need to agree that the subject meets the eligibility criterion (TMVDS grade 2 to 3). If the subject is eligible, the BLE's assessment will be used for the Baseline of the primary endpoint.
Eligible subjects will be enrolled and randomly assigned in a 3:1 ratio at Screening to receive RHA4 or comparator product.
The TI will administer the fillers, and if necessary, subjects will receive a touch-up treatment with the same product that they received on Visit 1, 4 weeks after the initial treatment to optimize the results. If the touch-up treatment is administered, the subject will be asked to come to the site for an additional visit 4 weeks after the touch-up injection.
Subjects will be followed for 52 weeks after their last treatment (initial treatment or touch-up), at which point, they will be offered re-treatment with RHA® 4, regardless of their original treatment, provided that the TI deems the treatment to be appropriate and the subject agrees. Reasons for not administering the re-treatment will be documented.
The subject will then be followed for an additional 12 weeks before exiting the study. If the subject or the TI declines re-treatment, this visit (52 weeks after the last treatment) will be considered the study Exit visit.
For subjects with re-treatment, the Exit visit will be 12 weeks after the re-treatment.
The TI will conduct safety and effectiveness evaluations at each study visit, which will occur: at 4 weeks after the initial and touch-up treatment, 8, 24, and 52 weeks after the last treatment, and after re treatment or until all treatment-related ongoing adverse events (AEs) have resolved or resolved with sequelae as per TI judgment or if follow-up is no longer possible.
A follow-up telephone call for safety will be performed 3 days after each treatment.
Subjects will report their common treatment responses (CTRs) in a subject diary for 30 days after each injection. The diary will also include a list of selected AEs potentially associated with injection of dermal fillers for subjects to report if applicable. All efforts should be made by the TI to schedule the applicable visits to allow completion of the CTR diary.
A BLE will conduct assessments of effectiveness during the study, including assessment of the primary endpoint 8 weeks after the last treatment.
The BLE will be blinded to allocation to groups (RHA4 group or comparator product group).
Furthermore, to ensure that they remain blinded and unbiased when making their assessments throughout the study, the BLE, TI, and subjects will not be allowed to refer to each other's effectiveness assessments. All subjects will be instructed to not discuss their study treatment, AEs, or CTRs with the BLE.
Conditions
- Cheek Augmentation
- Correction of Age-related Midface Contour Deficiencies
Interventions
- DEVICE
-
injection of RHA®4 in Midface
RHA® 4 is a sterile, biodegradable, biocompatible, viscoelastic, clear, colorless, homogenized gel implant. It consists of cross-linked hyaluronic acid produced by fermentation of Streptococcus equi bacteria, formulated to a concentration of 23 mg/mL and 0.3% w/w lidocaine in a physiologic buffer. Up to 3.0 mL injected per cheek (subcutaneous and/or supraperiosteal layer). Touch-up treatment provided at 4 weeks (up to 3.0 mL per cheek).
- DEVICE
-
injection of Comparator Product in Midface
Comparator product is sterile, biodegradable, colorless gel of hyaluronic acid generated by Streptococcus species of bacteria, chemically crosslinked with BDDE. Up to 3.0 mL injected per cheek (subcutaneous and/or supraperiosteal layer). Touch-up treatment provided at 4 weeks (up to 3.0 mL per cheek).
Sponsors & Collaborators
-
Teoxane SA
lead INDUSTRY
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 22 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2021-10-29
- Primary Completion
- 2023-01-17
- Completion
- 2024-01-29
Countries
- United States
Study Locations
More Related Trials
-
TEOSYAL RHA® 1 for Neck Lines, Perioral Lines and Smiling Lines
NCT05349799 ·Status: UNKNOWN ·Phase: NA
-
RHA® Redensity With New Anesthetic Agent - Perioral Rhytids
NCT04069585 ·Status: COMPLETED ·Phase: NA
-
Efficacy and Safety of "LMW - CL - HA - FACE/BODY" for the Augmentation of the Cheeks
NCT06915402 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Evaluation of Efficacy and Safety of Hyaluronic Acid (HA) Product for Cheek Augmentation
NCT02396251 ·Status: TERMINATED ·Phase: NA
-
RHA® 3 Versus Restylane-L® for Lip Augmentation
NCT04540913 ·Status: COMPLETED
-
Sculptra for Correction of Midface Volume Deficit and/or Midface Contour Deficiency
NCT04132518 ·Status: COMPLETED ·Phase: NA
-
TEOSYAL RHA® 1 for the Correction of Moderate to Severe Tissue Volume Deficiency in the Infraorbital Region in Chinese Adults
NCT06749587 ·Status: RECRUITING ·Phase: NA
-
A Study to Evaluate Effectiveness and Safety of Hyaluronic Acid (HA) Fillers
NCT03869450 ·Status: COMPLETED ·Phase: NA
-
Teosyal RHA® Histology and Intradermal Implantation Evaluation Study
NCT04846530 ·Status: UNKNOWN
-
Safety, Effectiveness and Participant Satisfaction Study of a Dermal Filler (of RADIESSE® (+) Lidocaine) in the Treatment of Ageing Signs in the Face
NCT03650387 ·Status: COMPLETED ·Phase: NA
-
A Clinical Study to Evaluate the Efficacy and Satisfaction of RHC Serum Combined With RHC(III) Injection
NCT06322875 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
RHA® Redensity With New Anesthetic Agent Perioral Rhytids (PAS)
NCT06378086 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
An Evaluation of an Injectable Material for Correction of Wrinkles
NCT00510081 ·Status: WITHDRAWN ·Phase: PHASE3
-
Evaluation of the Effectiveness and Safety of Radiesse for the Correction of Moderate to Severe Nasolabial Folds
NCT04647721 ·Status: COMPLETED ·Phase: NA
-
A Slit Face Trial Using Micro-injections of Transparent Hyaluronic Acid Gel for Rejuvenation of the Cheek
NCT02679924 ·Status: UNKNOWN ·Phase: NA
-
A Study of the Safety and Effectiveness of JUVÉDERM VOLUMA® XC Injectable Gel for Cheek Augmentation Using Cannula
NCT03438266 ·Status: COMPLETED ·Phase: NA
-
A Study to Assess Safety and Effectiveness of HArmonyCa Lidocaine Injectable Gel for Restoration and/or Creation of Mid-Face Volume in Adult Participants
NCT07032597 ·Status: ACTIVE_NOT_RECRUITING ·Phase: PHASE3
-
RADIESSE Injection in Perioral and Marionette Lines
NCT04172740 ·Status: COMPLETED ·Phase: NA
-
Restylane Perlane Lidocaine for Correction of Midface Volume Deficit and/or Midface Contour Deficiency
NCT03097783 ·Status: COMPLETED ·Phase: NA
-
Evaluation of Anti-aging Performance and Tolerance of a Hyaluronic Acid-based Filler NCTF135HA®
NCT05609617 ·Status: COMPLETED ·Phase: NA
-
Micro-injections of Transparent Hyaluronic Acid Gel (Restylane® Silk) for Rejuvenation of the Aging Cheek
NCT03461198 ·Status: UNKNOWN ·Phase: NA
-
Restylane Volyme for Correction of Midface Volume Deficit and/or Midface Contour Deficiency
NCT03289052 ·Status: COMPLETED ·Phase: NA
-
A Post-market-clinical Follow-up Investigation of Safety and Performance by Decoria® Voluma
NCT06565988 ·Status: COMPLETED ·Phase: NA
-
Safety and Effectiveness of Juvéderm® VOLUMA XC Injectable Gel for Cheek Augmentation
NCT00978042 ·Status: COMPLETED ·Phase: NA
-
Gene Expression Study Between Two Dermal Injectables Hydroxylapatite Semi-permanent Filler
NCT05620043 ·Status: COMPLETED ·Phase: NA