Validating the Accuracy of a Continuous Respiratory Rate Measurement Device
NCT04712240 · Status: COMPLETED · Phase: NA · Type: INTERVENTIONAL · Enrollment: 169
Last updated 2022-05-18
Summary
While respiratory rate is considered a critical vital sign, it often goes unmeasured or is ignored primarily due to shortcomings of the currently used measurement methods. Respiratory rate provides important information on a person's health condition and physiological stability, and an abnormal respiratory rate is a strong indicator that a health crisis is imminent. In fact, a sudden change in respiratory rate is one of the strongest predictors of mortality. Current techniques of monitoring respiratory rate have drawbacks that limit the frequency and convenience of the respiratory monitoring. Recognizing that closer respiration monitoring can save lives and improve quality of life, reduce hospital stays, and lower medical costs, the health care industry is seeking improved respiration monitoring products. The allocation of high-risk patients to intensive care for more careful monitoring or after surgery is often arbitrary, and such care might not be available routinely. For those patients who are cared for in 'general' wards where staffing levels are limited, a practical continuous monitor of respiratory rate would be of great value. This study will act as a pilot to determine the feasibility of using respiratory sensor device to monitor respiratory rate in hospitalized patients.
Deriving a measurement of respiratory rate from a respiratory rate monitoring (RRM) device is a technological approach that may overcome these limitations. The device principle is based on a piezoelectric sensor where chest expansions and contractions generate very small amounts of current by the piezoelectric sensor. The expansion and contractions are measured very accurately by over-sampling, filtering and digital signal processing to remove noise and any bias generated by the piezoelectric sensor itself or the sampling circuitry.
The study will be conducted from March 2021 to September 2021. During the first phase a convenience sample of 30 patients undergoing general anesthesia with muscle paralysis and mechanical ventilation will be recruited. This phase will help to validate the RRM against capnography in mechanically ventilated patients with a set respiratory rate. Following the first phase, 120 patients undergoing a procedure using sedation or spinal anesthesia will be recruited. Patients will be breathing spontaneously, and the respiratory rate will be monitored by capnography connected to the face mask or nasal prongs. Respiratory rate detected by capnography is recorded in the electronic medical records on a minute to minute interval.
Conditions
- Validation of Respiratory Rate Monitor Versus Capnography
Interventions
- DEVICE
-
Respiration rate monitor
A portable continuously monitoring respiration rate monitor will be fitted to each participant. The respiration rate monitor is housed within a comfortable chest strap that be secured to the participant for the duration of the surgical procedure
Sponsors & Collaborators
-
University of Calgary
lead OTHER
Study Design
- Allocation
- NA
- Purpose
- DIAGNOSTIC
- Masking
- NONE
- Model
- SINGLE_GROUP
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2021-11-17
- Primary Completion
- 2022-01-13
- Completion
- 2022-01-13
Countries
- Canada
Study Locations
More Related Trials
-
Respiratory Rate Validation Study
NCT05856422 ·Status: COMPLETED
-
Validation of Respiratory Rate and Heart Rate Measurements by Capaciflectors Placed in Four Locations on the Chest
NCT03832205 ·Status: COMPLETED
-
A-line/CareTaker Comparison Study in ICU Patients
NCT02479724 ·Status: COMPLETED
-
Assessment of Continuous Measurement of Transcutaneous CO2 for Evaluation of Alveolar Dead Space During Exercise
NCT03718780 ·Status: UNKNOWN ·Phase: NA
-
Non-invasive Venous Pressure Estimation
NCT07226479 ·Status: RECRUITING ·Phase: NA
-
Application of Indicator Based-electrical Impedance Tomography Method Assess Lung Regional Perfusion in ICU Patients
NCT04081142 ·Status: COMPLETED
-
Reassure Remote Respiration Monitoring in Heart Failure Patients
NCT02624739 ·Status: TERMINATED ·Phase: NA
-
Association Between EIT and CT During PEEP Titration in Patients With Acute Respiratory Failure
NCT07175194 ·Status: RECRUITING
-
Noninvasive Assessment of Tissue Perfusion Status in Critically Ill Pediatric Patients
NCT01760044 ·Status: COMPLETED ·Phase: NA
-
Lung Volume Change Between Noninvasive Positive Pressure Ventilation by Nasal Pillow and High Flow Nasal Cannula
NCT02292992 ·Status: UNKNOWN ·Phase: NA
-
Electrical Impedance Tomography for Optimization of Positive End-Expiratory Pressure: Acute Respiratory Distress Syndrome
NCT03793842 ·Status: COMPLETED ·Phase: NA
-
By Assessing the Continuous Respiratory Physiological Changes Through Prone Position, Determine the Optimal Duration for Prone Position
NCT06827184 ·Status: RECRUITING
-
Scintigraphic Comparison of Lung Deposition With Two Nebulizers During Invasive Mechanical Ventilation
NCT02450279 ·Status: TERMINATED ·Phase: NA
-
Substantial Equivalence Study for Kai Sensors RSpot Non-Contact Respiratory Rate Spot Check
NCT00827905 ·Status: COMPLETED
-
Differentiation of Upper and Lower Respiratory Tract Infections Using Automated Lung Sound Analysis With LungPass Device
NCT05175612 ·Status: SUSPENDED
-
Using Ultrasound to Study Respiratory Muscle Function in Critically Ill Patients
NCT03139695 ·Status: COMPLETED
-
Electrical Impedance Tomography (EIT) Monitoring in Adults With ALI or ARDS
NCT01272882 ·Status: COMPLETED ·Phase: NA
-
Comfort Evaluation of Non-Invasive Respiratory Monitor Interfaces
NCT01494844 ·Status: COMPLETED ·Phase: EARLY_PHASE1
-
Functional Bed Sheet Capturing Pressure Variation and Respiratory Effort Over Time
NCT03119103 ·Status: COMPLETED ·Phase: NA
-
Effect of High-flow Nasal Cannula Oxygen on Lung Volumes Determined by Electrical Impedance Tomography
NCT02186288 ·Status: COMPLETED
-
Respiratory Monitoring System Safety and Performance Study
NCT05812378 ·Status: UNKNOWN
-
Mathematical Arterialisation of Capillary Blood for Blood Gas Analysis in Critical Ill Patients
NCT04144296 ·Status: UNKNOWN ·Phase: NA
-
Assessment of Tidal Volume During Non Invasive Oxygenation Techniques
NCT03445455 ·Status: UNKNOWN
-
Electrical Activity of the Diaphragm During the Weaning Period
NCT01411722 ·Status: COMPLETED ·Phase: PHASE2
-
Clinical Utility of Capnography in the PACU( Post-anaesthesia Care Unit)
NCT02707003 ·Status: COMPLETED