A PROSPECTIVE, MULTI-CENTER, SINGLE-ARM, POST MARKET OBSERVATIONAL STUDY TO EVALUATE THE SAFETY AND CLINICAL PERFORMANCE OF THE ARCHIMEDES BIODEGRADABLE BILIARY AND PANCREATIC STENT
NCT04708288 · Status: UNKNOWN · Type: OBSERVATIONAL · Enrollment: 198
Last updated 2023-03-29
Summary
Significant experience with biodegradable materials has been reported in the orthopedic literature; in particular; biodegradable stents have been used in the endovascular and urologic epithelium. Stents are typically made from polymeric materials including Polylactic Acid (PLA), Polyglycolide (PGA), Polydioxanone (PDO), Polyethyleneglycol (PEG), Polycaprolactone (PCL), etc., which have been cleared or approved by the FDA and CE-marked as drug carriers, sutures, and bone fixatives. The material is degraded by hydrolysis in, e.g., lactic acid, which is removed from the body by normal metabolic pathways. In the field of gastroenterology, these stents were first introduced in patients with an esophageal stenosis with encouraging results, although esophageal hyperplasia was a frequently encountered complication.
For biliary applications, biodegradable stents have been evaluated in several in-vitro and animal studies that demonstrated that the stents were safe and well tolerated. These stents provided an adequate radial force and resulted in complete stricture resolution within several months. The stents did not show any signs of biliary hyperplasia or integration in the epithelium. Moreover, they seem to have a self-clearing effect on attached biofilm as the outer layer sloughs during the degradation process similarly to the exfoliation of human skin. Also, the stent could be removed from the bile duct, thus offering the possibility of extraction if necessary at various times after implantation.
In 2010, Petryl was the first to use a biodegradable stent in the human bile duct. A stent was successfully placed using percutaneous transhepatic cholangiograpy in two patients with a postsurgical intrahepatic biliary stricture. Transient cholangitis was the only complication encountered and during the two years of follow-up, the bile duct remained patent.
Later, Mauri et al. presented in 2013 and 2016 results of a 107 patient study on a polydioxanone biodegradable biliary stent. The results have been published in the Journal of the European Society of Radiology. The authors concluded that percutaneous placement of a biodegradable biliary stent is a feasible and safe strategy to treat benign biliary strictures refractory to standard bilioplasty, with promising results in the mid-term period.
Prior to this study, the ARCHIMEDES device was assessed in the ARCHIMEDES Investigational study which has completed enrolment with 53 patients included, and the results are not yet published. In this study approximately half the stents were deployed in the bile duct (53%) and half in the pancreatic duct. All 53 patients have either completed, exited, or no longer have the study device. No patient remains in the study with a stent in place during the time of the last patient follow-ups. The study concluded without any device-related SAE. Bilirubin was reduced by 25.6%, which exceeded the \>20% clinical success criterion, quality of life score improved from 3.7 to 7.9, procedural success was rated 1.4 (good to excellent), and technical success was achieved in all 53 patients.
Data from the ARCHIMEDES Investigational study was used for CE Mark approval, which was obtained in June 2018.
Conditions
- Obstructed Biliary and Pancreatic Duct
Interventions
- DEVICE
-
ARCHIMEDES Biodegradable Biliary and Pancreatic Stent
Pts that will receive ARCHIMEDES Biodegradable Biliary and Pancreatic Stent
Sponsors & Collaborators
-
QualiMed Innovative Medizinprodukte GmbH
lead INDUSTRY
Eligibility
- Min Age
- 18 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2020-09-22
- Primary Completion
- 2023-12-31
- Completion
- 2023-12-31
Countries
- Finland
- Germany
- Israel
- Italy
- Slovenia
- Spain
Study Locations
More Related Trials
-
Supra-papillary Versus Trans-papillary Biliary Stenting in Malignant Peri-hilar Stenosis
NCT07325877 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Endoscopic Treatment of Benign Biliary Strictures and Cystic Duct Leakages With a Novel Biodegradable Biliary Stent
NCT02353286 ·Status: COMPLETED ·Phase: NA
-
Comparison Between Winged Versus Traditional Plastic Stents for Biliary Drainage
NCT06960733 ·Status: COMPLETED ·Phase: NA
-
Biodegradable Pancreatic Stents for the Prevention of Postoperative Pancreatic Fistula After Cephalic Pancreaticoduodenectomy
NCT04783831 ·Status: UNKNOWN
-
*Effect of Prophylactic CBD Stenting Versus Non Stenting on Recurrence of CBD Stones in Patients Awaiting Cholecystectomy*
NCT07084493 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Randomized Controlled Trial on Pancreatic Stent Tube in Pancreaticoduodenectomy
NCT00628186 ·Status: COMPLETED ·Phase: NA
-
Preoperative Stent Study
NCT00501176 ·Status: COMPLETED ·Phase: NA
-
7 cm vs. 5 cm Pancreatic Stents for the Prevention of Post-ERCP Pancreatitis in High-risk Patients
NCT04145336 ·Status: UNKNOWN ·Phase: NA
-
Post-ERCP Pancreatitis Prevention by Stent Insertion
NCT01673763 ·Status: COMPLETED ·Phase: NA
-
Internal Biodegradable Stent Versus Non-Stent in Patients at High-Risk of Developing Fistula After Pancreatoduodenectomy
NCT05668260 ·Status: RECRUITING ·Phase: NA
-
Gallbladder Stenting in FC-SEMS
NCT06820541 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
The Usefulness of Endoscopic Ultrasound-guided Biliary Drainage With a Newly Designed Hybrid Metallic Stent
NCT01862198 ·Status: COMPLETED ·Phase: PHASE4
-
CBD Stenting vs Non-Stenting for Choledocholithiasis
NCT07331142 ·Status: COMPLETED ·Phase: NA
-
Sems Placement With and Without Biliary Sphincterectomy in Patients With Malignant Biliary Obstruction
NCT04805450 ·Status: UNKNOWN ·Phase: NA
-
Endoscopic Pancreatic Duct Stent Placement Versus Conventional Approach in the Treatment of Early Phase Acute Pancreatitis
NCT07093996 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
A Prospective, Randomized Study Evaluating the Effect of Biliary Stenting on EAU-FNA in Patients With Suspected Malignant Biliary Obstruction
NCT01514058 ·Status: TERMINATED ·Phase: NA
-
Double Stent for Biliary Stones in Cirrhotic Patients
NCT07337291 ·Status: COMPLETED ·Phase: NA
-
Biodegradable Biliary Stent for Post Operative Cystic Duct Leakage
NCT00493675 ·Status: WITHDRAWN ·Phase: PHASE1
-
Spontaneous Dislocation and Adverse Events of a Prophylactic Pancreatic Stent
NCT07346365 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Cholangioscopic Assessment of Occluded Biliary Stent and Role of Biliary Radiofrequency Ablation
NCT03133026 ·Status: UNKNOWN ·Phase: NA
-
Does Pancreatic Stent Decrease the Risk of Pancreatitis After Pancreatic Sphincterotomy for Difficult Cannulation?
NCT04408482 ·Status: RECRUITING ·Phase: NA
-
Optimal Placement Duration of Pancreatic Duct Stent
NCT04691674 ·Status: COMPLETED ·Phase: NA
-
Immediate vs. Elective Endoscopic Removal of Large CBD Stones in High-Risk Elderly Patients
NCT06948279 ·Status: COMPLETED ·Phase: NA
-
RADIO FREQUENCY ABLATION IN UNRESECTABLE MALIGNANT BILIARY OBSTRUCTION
NCT05320328 ·Status: UNKNOWN
-
Gentamicin in Preventing Post Endoscopic Retrograde Cholangiopancreatography (ERCP) Cholangitis in Non-calculus Stenting
NCT01148693 ·Status: COMPLETED ·Phase: NA