Comparison of PolarX and the Arctic Front Cryoballoons for PVI in Patients With Symptomatic Paroxysmal AF

NCT04704986 · Status: ACTIVE_NOT_RECRUITING · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 201

Last updated 2025-02-19

No results posted yet for this study

Summary

Pulmonary vein isolation (PVI) is an effective treatment for atrial fibrillation (AF). Single shot devices are increasingly used for PVI. Currently, Medtronic Arctic Front cryoballoon is the most frequently used single shot technology and hence is the benchmark for upcoming technologies. A novel cryoballoon technology has recently been introduced (PolarX, Boston Scientific). However, whether PolarX provides effectiveness similar to the standard-of-practice Medtronic Arctic Front cryoballoon is yet to be investigated. Given that PolarX was developed considering the reported limitations and potential failures associated with the Medtronic Arctic Front cryoballoon, it might be even more effective and safe for use in AF ablation procedures.

The aim of this trial is to compare the efficacy and safety of the PolarX Cryoballoon (Boston Scientific) and the Arctic Front Cryoballoon (Medtronic) in patients with symptomatic paroxysmal AF undergoing their first PVI.

This is an investigator-initiated, multicenter, randomized controlled, open-label trial with blinded endpoint adjudication. Given that the Medtronic Arctic Front Cryoballoon is the standard-of-practice for single shot PVI and the PolarX is the novel technology, this trial has a non-inferiority design.

The hypothesis with regards to the primary efficacy endpoint is that the PolarX Cryoballoon (Boston Scientific) shows lower efficacy compared to the Arctic Front Cryoballoon (Medtronic) and that therefore more episodes of first recurrence of any atrial arrhythmia between days 91 and 365 will be observed in patients with symptomatic paroxysmal AF undergoing their first PVI. Hence the alternative hypothesis postulates that the PolarX Cryoballoon is non-inferior to the Arctic Front Cryoballoon. Rejection of the null hypothesis is needed to conclude non-inferiority.

Conditions

  • Paroxysmal Atrial Fibrillation

Interventions

DEVICE

PVI using the Arctic Front Cryoballoon (Medtronic)

Patients randomized to the Arctic Front cryoballoon group will undergo PVI using the Arctic Front Cryoballoon (Medtronic). At the end of the procedure, an implantable cardiac monitor (Medtronic Reveal LINQ) will be implanted for the purpose of continuous arrhythmia monitoring.

DRUG

PVI using the PolarX Cryoballoon (Boston Scientific)

Patients randomized to PolarX cryoballoon group will undergo PVI using the PolarX Cryoballoon (Boston Scientific). At the end of the procedure, an implantable cardiac monitor (Medtronic Reveal LINQ) will be implanted for the purpose of continuous arrhythmia monitoring.

Sponsors & Collaborators

  • University Hospital, Basel, Switzerland

    collaborator OTHER
  • Insel Gruppe AG, University Hospital Bern

    lead OTHER

Principal Investigators

  • Tobias Reichlin, MD · Inselspital, Bern University Hospital

Study Design

Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Model
PARALLEL

Eligibility

Min Age
18 Years
Sex
ALL
Healthy Volunteers
No

Timeline & Regulatory

Start
2021-03-29
Primary Completion
2023-07-31
Completion
2025-07-31

Countries

  • Switzerland

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04704986 on ClinicalTrials.gov