Cryoenergy Or Radiofrequency for Pulmonary Vein Isolation
NCT00969735 · Status: COMPLETED · Phase: PHASE4 · Type: INTERVENTIONAL · Enrollment: 50
Last updated 2013-04-04
Summary
This is a prospective single-center randomized trial comparing the efficacy and safety of PV cryoablation with the Arctic Front® catheter versus the standard PV isolation using radiofrequency irrigated tip catheters. The efficacy of both strategies will be evaluated from a clinical point of view and from the detection and quantification of AF episodes by means of the Reveal XT® implantable loop recorder.
Conditions
Interventions
- DEVICE
-
Pulmonary vein cryoablation
A deflectable over-the-wire cryoablation balloon catheter (Arctic Front®) will be inflated and be positioned at each PV antrum. Then, cryoenergy will be delivered for 300 seconds. During cryoablation of the right PVs, the right phrenic nerve integrity will be monitored by the observation of right hemi-diaphragm contractions in response to right phrenic nerve pacing at the superior vena cava. Once the 4 PVs are cryoablated, the Arctic Front® catheter will be replaced by a decapolar PV mapping circular catheter (Lasso®, Biosense Webster, Diamond Bar, California, EEUU) to evaluate PV conduction. A second cryoablation application may be delivered at each PV, if necessary. Crossover to RF ablation to complete PV isolation is discouraged.
- DEVICE
-
Pulmonary vein radiofrequency ablation
Ablation approach is ostial electrical isolation of all PVs with simultaneous use of the CARTO® electroanatomic mapping system (Biosense Webster, Tirat-Ha-Carmel, Israel). PV isolation will be performed by delivering RF energy at ostial sites with earliest PV potentials. Flow rate during the RF applications will be set at 15 mL/min (baseline 2 mL/min). Temperature and power limits will be set at 45ºC and 35 W. It will be allowed a 5 W reduction in power limit setting for small PVs (angiographic supero-inferior diameter \> 12 mm), and a 5 W increase in areas located away from the esophagus, and for focal applications at sites resistant to ablation or recurrent gaps. The end-point of ablation will be to achieve bidirectional PV conduction block.
Sponsors & Collaborators
-
Spanish Society of Cardiology
collaborator OTHER -
Hospital San Carlos, Madrid
lead OTHER
Principal Investigators
-
Nicasio Pérez Castellano, MD, PhD · Unidad de Arritmias, Hospital Clínico San Carlos, Madrid, Spain
Study Design
- Allocation
- RANDOMIZED
- Purpose
- TREATMENT
- Masking
- QUADRUPLE
- Model
- PARALLEL
Eligibility
- Min Age
- 18 Years
- Max Age
- 75 Years
- Sex
- ALL
- Healthy Volunteers
- No
Timeline & Regulatory
- Start
- 2009-07-31
- Primary Completion
- 2012-05-31
- Completion
- 2012-05-31
Countries
- Spain
Study Locations
More Related Trials
-
Pulsed Field Ablation vs Cryoablation In Paroxysmal Atrial Fibrillation
NCT05940597 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Cryoballoon Ablation in Patients With Longstanding Persistent Atrial Fibrillation
NCT02294929 ·Status: UNKNOWN ·Phase: NA
-
Cryoballoon Pulmonary Vein Isolation vs. Radiofrequency Pulmonary Vein Isolation With Additional Right Atrial Linear Ablation for Paroxysmal Atrial Fibrillation: Prospective Randomized Trial (CRAPAF Trial)
NCT03920917 ·Status: UNKNOWN ·Phase: NA
-
Evaluation of the Efficacy of Pulmonary Vein Isolation by Pulsed-field Ablation in Persistent Atrial Fibrillation: a Multicenter Study With Follow-up by Implantable Cardiac Monitor
NCT06985901 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
PV-Isolation With the Cryoballoon Versus RF:a Randomized Controlled Prospective Non-inferiority Trial (FreezeAF)
NCT00774566 ·Status: COMPLETED ·Phase: PHASE4
-
Left Atrial Arrhythmia Substrate Identification After Confirmed durABLE Pulmonary Vein Isolation
NCT04111731 ·Status: COMPLETED ·Phase: NA
-
EXPORT Randomized Trial
NCT07197931 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Safety and Feasibility of Electrical Isolation of the Superior Vena Cava for Paroxysmal Atrial Fibrillation
NCT03190096 ·Status: UNKNOWN
-
Left Atrial Posterior Wall and PV Isolation Using Cryoballoon for Treatment of Persistent AF
NCT04505163 ·Status: UNKNOWN ·Phase: NA
-
SVC-isolation in Redo-AF Ablation With Isolated PV
NCT07112716 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Efficacy of Pulmonary Vein Isolation Alone in Patients With Persistent Atrial Fibrillation
NCT03514693 ·Status: UNKNOWN ·Phase: NA
-
CLOSE-guided Pulmonary Vein Isolation Using High Power and Stable RF Applications
NCT04122963 ·Status: COMPLETED ·Phase: NA
-
Pulmonary Vein (PV) -Isolation: Arrhythmogenic Vein(s) Versus All Veins
NCT00605748 ·Status: UNKNOWN ·Phase: PHASE4
-
FIRE AND ICE: Comparative Study of Two Ablation Procedures in Patients With Atrial Fibrillation
NCT01490814 ·Status: COMPLETED ·Phase: NA
-
Reduction of Radiation Dose and Contrast Use During Cryoballoon Pulmonary Vein Isolation
NCT03786822 ·Status: COMPLETED ·Phase: NA
-
Pulmonary Vein Isolation With Versus Without Continued Antiarrhythmic Drugs in Persistent Atrial Fibrillation
NCT03437356 ·Status: COMPLETED ·Phase: NA
-
Combined Pulsed Field and Radiofrequency Energy for Ablation of Ventricular Tachycardia
NCT06816368 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Unipolar Atrial Electrogram Modification Combined to the Contact Force Sensing Technology for Pulmonary Vein Isolation
NCT02520960 ·Status: COMPLETED
-
The Effect of Pulse Field Ablation on Atrial Mechanics in Catheter Ablation of Paroxysmal Atrial Fibrillation
NCT06557876 ·Status: RECRUITING ·Phase: NA
-
Substrate Versus Trigger Ablation for Paroxysmal Atrial Fibrillation
NCT02169037 ·Status: UNKNOWN ·Phase: NA
-
Trigger- vs. Substrate-Ablation for Paroxysmal Atrial Fibrillation
NCT00196183 ·Status: COMPLETED ·Phase: PHASE4
-
STrategies for Catheter Ablation of peRsistent Atrial Fibrlllation
NCT04428944 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Mesh Ablator Versus Cryoballoon Pulmonary Vein Ablation of Symptomatic Paroxysmal Atrial Fibrillation
NCT01061931 ·Status: TERMINATED ·Phase: PHASE4
-
Ablation Index Guided High Power Ablation for Pulmonary Vein Isolation in Patients With Atrial Fibrillation
NCT04379557 ·Status: UNKNOWN ·Phase: NA
-
Implantable Loop Recorder Versus Conventional Ambulatory Monitoring in Detecting Atrial Fibrillation After Pulmonary Vein Isolation
NCT00697359 ·Status: COMPLETED ·Phase: NA