Neurophysiological Marker of ADHD in Children

NCT04467658 · Status: COMPLETED · Type: OBSERVATIONAL · Enrollment: 140

Last updated 2024-02-20

No results posted yet for this study

Summary

This study investigated quantitative electroencephalography (QEEG) subtypes as auxiliary tools to assess Attention Deficit Hyperactivity Disorder (ADHD). Patient assessed using the Korean version of the Diagnostic Interview Schedule for Children Version IV and were assigned to one of three groups: ADHD, ADHD-Not Otherwise specified (NOS), and Neurotypical (NT). The investigators measure absolute and relative EEG power in 19 channels and conducted an auditory continuous performance test. The investigators analyzed QEEG according to the frequency range: delta (1-4 Hz), theta (4-8 Hz), slow alpha (8-10 Hz), fast alpha (10-13.5 Hz), and beta (13.5-30 Hz). The subjects were then grouped by Ward's method of cluster analysis using the squared Euclidian distance to measure dissimilarities.

Conditions

  • Attention Deficit Hyperactivity Disorder
  • Psychiatric Diagnosis
  • Diagnosis, Psychiatric

Interventions

DIAGNOSTIC_TEST

electroencephalography absolute delta power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography relative delta power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography absolute theta power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography relative theta power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography absolute slow alpha power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography relative slow alpha power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography absolute fast alpha power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography relative fast alpha power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography absolute beta power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

electroencephalography relative beta power

We used MATLAB 7.0.1 (Math Works, Natick, MA, USA) and the EEGLAB toolbox to pre-process and analyze the EEG recordings. First, the EEG data were down-sampled to 250 Hz. Next, the EEG data were detrended and mean-subtracted to remove the DC component. A 1-Hz high-pass filter and a 60-Hz notch filter were applied to remove eye and electrical noise. Next, independent component analysis (ICA) was performed to remove the well-defined sources of artifacts. ICA has been shown to reliably isolate artifacts caused by eye and muscle movements and heart noise (23). Finally, clinical psychiatrists and EEG experts visually inspected the corrected EEGs. For the analysis, we selected more than two minutes of artifact-free EEG readings from the three-minute recordings

DIAGNOSTIC_TEST

Korean ADHD rating scale

The KARS is a standardized screening tool for ADHD in Korean children and rating scale completed by the parents.

DIAGNOSTIC_TEST

Korean Version of Diagnostic Interview Schedule for Children Version IV

The DISC-IV is a structured diagnostic tool that was developed for use in epidemiological studies in children and adolescents

Sponsors & Collaborators

  • Daegu Catholic University Medical Center

    lead OTHER

Eligibility

Min Age
7 Years
Max Age
12 Years
Sex
ALL
Healthy Volunteers
Yes

Timeline & Regulatory

Start
2018-08-08
Primary Completion
2021-02-28
Completion
2021-02-28

Countries

  • South Korea

Study Locations

More Related Trials

Read the full study record

This page highlights key information. For complete eligibility criteria, study locations, investigator contacts, and the full protocol, visit the original record on ClinicalTrials.gov.

View NCT04467658 on ClinicalTrials.gov