Comparison of Patient Satisfaction and Primary Implant Stability Between Two Different Magnetic Attachment
NCT04438616 · Status: UNKNOWN · Phase: NA · Type: INTERVENTIONAL · Enrollment: 28
Last updated 2020-06-19
Summary
* Patients were randomly divided in to two groups by using computerized software ; the first group received flat magnetic attachment design while the second group received dome magnetic attachment design.which the inclusion criteria is completely edentulous patient ,Age range from 40 to 70 year old ,skeletal class 1, both sexes
* Implant stability will be measured for both groups using smart peg /osstell at the day of implant installation and after 2,4,8,12 weeks.
* Patient satisfaction measure in 2 weak and after 12 weak by Denture satisfaction questionnaire
Conditions
- Edentulous Alveolar Ridge
Interventions
- PROCEDURE
-
dome magnetic attachment
* All patients will receive complete denture before implant installation . * The CBCT examination should be take * patients received infiltration local anesthesia * A crestal incision is made using No. 15 c blade . * Full sequential drilling under copious saline irrigation will be made . insertion of two implant by the contra angle handpiece with special adaptor * We connect magnetic attachment(dome) on complete denture by pick up procedure at day of implant installation. * Implant stability will be measured using smart peg /osstell at the day of implant installation and after 2,4,8,12 weeks. * Patient satisfaction measure
- PROCEDURE
-
flat magnetic attachment
* All patients will receive complete denture before implant installation . * The CBCT examination should be take * patients received infiltration local anesthesia. * A crestal incision is made using No. 15 c blade * Full sequential drilling under copious saline irrigation will be made as indicated by the company guide lines. insertion of two implant by the contra angle handpiece with special adaptor * We connect magnetic attachment(flat) on complete denture by pick up procedure at day of implant installation. * Implant stability will be measured using smart peg /osstell at the day of implant installation and after 2,4,8,12 weeks. * Patient satisfaction measure in 2 weak and after 12 weak by Denture satisfaction questionnaire
Sponsors & Collaborators
-
Cairo University
lead OTHER
Study Design
- Allocation
- RANDOMIZED
- Purpose
- OTHER
- Masking
- SINGLE
- Model
- PARALLEL
Eligibility
- Min Age
- 40 Years
- Max Age
- 70 Years
- Sex
- ALL
- Healthy Volunteers
- Yes
Timeline & Regulatory
- Start
- 2020-09-01
- Primary Completion
- 2021-01-30
- Completion
- 2021-04-30
More Related Trials
-
A Study Comparing Two Different Denture Base Materials in Implant Retained Overdentures
NCT07271641 ·Status: COMPLETED ·Phase: NA
-
Attachment Types for Single-implant Mandibular Overdentures: a Crossover Clinical Trial
NCT03048812 ·Status: COMPLETED ·Phase: NA
-
Using Two Different Attachments in Mandibular Implant Overdenture Cases in Order to Retention and Patient Satisfaction
NCT06678945 ·Status: ACTIVE_NOT_RECRUITING ·Phase: NA
-
Maintenance and Cost Effectiveness of Cendres Metaux Locator (CM-LOC) Resin Matrix Versus Ball Nylon Matrix Attachment Retaining Single Implant Mandibular Complete Overdentures
NCT02907515 ·Status: UNKNOWN ·Phase: NA
-
Screw-retained Maxillary Complete Denture With Electric Welded Metal Framework Versus Cast One, Patient Satisfaction Assessment.
NCT04539210 ·Status: UNKNOWN ·Phase: NA
-
Mandibular Overdentures Retained by Four Locator Attachments Versus Four-Implant Bar Attachments
NCT07093853 ·Status: RECRUITING
-
Evaluation of Different Attachments on Implant-Retained Mandibular Overdenture.
NCT06721377 ·Status: RECRUITING ·Phase: NA
-
Patient Satisfaction and Microbial Changes in Complete Dentures.
NCT03043456 ·Status: UNKNOWN ·Phase: NA
-
Assessment of Stability Using Satellite Implant for Immediate Loading in Posterior Mandible
NCT06486311 ·Status: NOT_YET_RECRUITING ·Phase: NA
-
Patient Satisfaction and Retention in Implant Supported Telescopic Overdenture With Different Copings
NCT04032223 ·Status: UNKNOWN ·Phase: NA
-
Effect of Implant Position on Clinical Outcomes
NCT06166316 ·Status: COMPLETED ·Phase: NA
-
Accuracy of Computer Guided Four Implants Placement in Completely Edentulous Mandible
NCT06571968 ·Status: COMPLETED ·Phase: NA
-
Oral Health Related Quality of Life and Peri-implant Condition in Single Implant Overdenture
NCT02861313 ·Status: COMPLETED ·Phase: NA
-
Direct Versus Indirect Pick up of the Locator Retentive Caps:(Within-patient Study)
NCT05289752 ·Status: COMPLETED ·Phase: NA
-
Socket Shield With Immediate Implant Stability
NCT04882761 ·Status: COMPLETED ·Phase: PHASE4
-
Ball Vs Locator Attachment in Overdenture Retained by Single Mandibular Implant
NCT02952274 ·Status: UNKNOWN ·Phase: NA
-
Effect of Different Implant Surface Treatments on Bony Changes Around Mandibular Implants
NCT04686370 ·Status: UNKNOWN ·Phase: NA
-
Bone Changes Assessment in Screw-Retained Maxillary Complete Denture With Electric Welded Framework Versus Cast One
NCT04548258 ·Status: UNKNOWN ·Phase: NA
-
Comparative Clinical Study for Two Types of Locator Attachments for Mandibular Implant Supported Overdenture
NCT06109519 ·Status: COMPLETED ·Phase: NA
-
Buccal Plate Augmentation Using Sticky Bone With Simultaneous Immediate Implant Placement
NCT06642753 ·Status: RECRUITING ·Phase: NA
-
Esthetic, Clinical and Radiographic Outcomes of Immediate and Delayed Implant Placement
NCT02814149 ·Status: RECRUITING ·Phase: NA
-
Crestal Bone Changes Following Equi-crestal Versus Subcrestal Implant Placement
NCT06760442 ·Status: RECRUITING ·Phase: NA
-
Effect of Digital Versus Static Jaw Relation Record on Crestal Bone Changes Around Implants Supporting Maxillary Single Overdenture
NCT06965517 ·Status: COMPLETED ·Phase: NA
-
Comparative Evaluation of Masticatory Efficiency of Implant Supported Overdenture
NCT05877092 ·Status: COMPLETED ·Phase: NA
-
Mandibular Implant Overdenture With OT Cap Bar vs Bar Attachment
NCT07067190 ·Status: NOT_YET_RECRUITING ·Phase: NA